• 제목/요약/키워드: $COD_T$

검색결과 854건 처리시간 0.023초

염색공장 폐수중 PVA 분해세균의 분리 및 생물학적 처리효과 (Studies on the Biological Treatment of Dye Waste Water and Degration of Polyvinyl Alcohol)

  • 강선태;서승교;권오억
    • 한국환경보건학회지
    • /
    • 제16권1호
    • /
    • pp.21-28
    • /
    • 1990
  • As a research for treatment of waste water by biological method, we investigated general characteristics of waste water and isolated some useful bacteria which effectively treated waste water. Compositions of waste water were analyzed to give COD 2060 ppm, PVA 560 ppm, T-N 50 ppm, T-P 3.3 ppm and PH 12. Also, we inverstigated optimum nutrients requirement and growth conditions by mixed culture as well as the effect of coagulants. The COD removal rate reached maximum state for 48 hrs culture at pH 7.0 and 30$^{\circ}$C. Alum as the coagulated was the most effective. The COD removal rate was also increased by supplementing 10 ppm phosphorous sources as additional nutrients. The COD of waste water was reduced to 10% of its initial value by the continuous culture. As a result of overall experiments the COD of effluents became about 100 ppm and final pH 7.

  • PDF

단상 및 이상혐기소화공정을 이용한 음폐수의 바이오에너지화 (The Single- and Two-Phase Anaerobic Digestion of Food Waste Effluent)

  • 황보준권;서재건;윤희철;박현건;이보원
    • 토지주택연구
    • /
    • 제2권1호
    • /
    • pp.87-92
    • /
    • 2011
  • 음식물폐기물 처리 과정에서 발생되는 음폐수의 효율적인 처리를 위한 혐기소화공정을 선정하기 위하여, 단상 및 이상혐기소화공정을 대상으로 데모플랜트(일 5톤 처리용량)를 활용하여 성능을 비교하였다. TS, VS, tCOD 및 sCOD 처리율을 비교하여 보면 모든 항목에서 단상혐기소화공정의 처리율이 우수하였지만, 바이오가스는 오히려 이상혐기소화공정에서 더 많이 발생하였다. 이는 단상혐기소화공정의 경우 운전기간 동안 음폐수 투입량이 상대적으로 적어 처리효율은 뛰어 났지만, 음폐수 투입량 변동에 따른 바이오가스의 발생이 민감하게 반응을 한 결과로 해석된다. 이상혐기소화공정의 경우 총 COD가 상대적으로 매우 낮은 수준임에도 불구하고 바이오가스 발생량은 단상혐기소화공정보다 많이 발생되었다. 이는 음폐수 투입량이 일정하게 유지되었고, 산발효공정과 메탄발효공정이 분리되어 운영됨으로써 공정 전체가 안정적으로 운영되었기 때문인 것으로 판단된다. 음폐수처리를 위해서는 공정 선정이 중요하지만 단순 유기물처리율 비교만으로는 종합적인 평가가 어려우며, 이를 보완하기 위하여 원료성상, 투입량, 처리율, 운전기간, 바이오가스발생량 등을 종합하여 소화성능을 평가하여야 할 것이다.

오염하천 정화를 위한 호기성 인공습지의 운영인자 평가 (Parameter Estimation of the Aerated Wetland for the Performance of the Polluted Stream Treatment)

  • 김둘선;이동근
    • 청정기술
    • /
    • 제25권4호
    • /
    • pp.302-310
    • /
    • 2019
  • 호기조와 혐기/무산소조를 직렬로 연결한 인공습지를 이용하여 크게 오염된 하천수를 처리하였다. 호기조는 자연 공기 배출 시스템을 통하여 공기가 연속적으로 공급되어 호기성 상태가 유지되었다. 인공습지의 성능에 영향을 미치는 최적의 영향인자를 조사하기 위하여 체류시간을 다르게 한 5개의 파일럿 플랜트를 사용하였다. 호기조에서 BOD (biochemical oxygen demand)와 COD (chemical oxygen demand)의 제거율은 1차 반응 속도식을 나타내었고, COD 제거 속도 상수는 BOD보다 약간 낮았다. 온도 의존성은 COD (θ = 1.0079)와 BOD (θ = 1.0083)제거에 대한 값이 거의 동일했으나 T-N 제거의 온도 의존성(θN)은 1.0189로 다소 높게 나타났다. SS제거율은 98%로 높았고 수력학적 부하 속도(Q/A)가 증가함에 따라 제거 효율이 증가하는 경향을 보였다. 혐기/무산소조에서 BOD와 COD 제거의 주요 메커니즘은 호기조와 완전히 다르게 나타났다. 혐기/무산소조에서 COD와 COD는 생물학적 탈질을 위한 탄소원으로 공급되었고 T-P는 혐기/무산소조 내의 orthophosphate와 자갈 사이의 양이온 교환에 의해 제거되는 것으로 조사되었다. 인공습지는 여과된 고형물에 의해 막힘 없이 성공적으로 운영되었고 고형물들은 매우 빠르게 연속적으로 분해되었다.

부처꽃, 물상추, 미나리, 달뿌리풀의 수질정화효과에 관한 연구 (A study on the effect of the water purification by Lythrum anceps, Pistia straiotes, Oenanthe javanica, and Phragmites japonica)

  • 조해용
    • 한국산학기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.380-384
    • /
    • 2007
  • COD 제거효율은 각 조의 부처꽃을 제외한 대조군의 경우 물상추 56%, 달뿌리풀 48%, 미나리 41%의 효율을 보이고, 발포유리가 첨가된 조의 경우는 물상추 69%, 달뿌리풀 68% 미나리 62%의 제거효율을 보임으로써 발포유리를 첨가한 조의 COD 제거효율이 대조군 보다 높았다. T-N의 제거효율은 발포유리를 첨가한 조의 경우 부처꽃 91%, 달뿌리풀 93%와 발포유리를 첨가한 혼합조가 94%의 높은 T-N 제거효율 보임으로써 모든 질소성분이 제거된 것으로 사료된다. T-P의 제거효율은 대조군의 부처꽃 35%, 달뿌리풀 8%이며, 발포유리를 첨가한 조의 부처꽃 78%, 달뿌리풀 43%로 발포유리를 첨가한조의 T-P 제거효율이 대조군 보다 높았다.

  • PDF

낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석 (Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin)

  • 조현경;김상민
    • 한국물환경학회지
    • /
    • 제34권2호
    • /
    • pp.202-209
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of a sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. Flow and water quality data, such as BOD, COD, SS, T-N, and T-P data, for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS, and T-P were correlated positively with the river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluents and downstream streams, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between the river flow rate and the water quality factors (COD, SS, TP) was high at river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석 (Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin)

  • 조현경;김상민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.493-493
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of the sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. The flow and water quality such as BOD, COD, SS, T-N, and T-P data for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS and T-P were correlated positively with river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluent and downstream stream, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between river flow rate and water quality factors (COD, SS, TP) was high for river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

  • PDF

양돈폐수 처리를 위한 혐기성 생물반응기의 성능 비교 (Performance Evaluation of Anaerobic Bioreactors in Treating Swine Wastewater)

  • 김종수;이국희;사동민
    • 대한환경공학회지
    • /
    • 제22권11호
    • /
    • pp.2047-2058
    • /
    • 2000
  • 양돈폐수의 효율적인 혐기성 처리를 위하여 실험실 규모 UASB, AF, 그리고 이단 ASBF 생물반응기를 구성하고 HRT 1일과 OLR $5.1kg-COD/m^3{\cdot}d$까지 200일간 연속운전하고 운전인자가 공정에 미치는 영향과 처리효율을 비교하였다. 양돈폐수는 유기물, 고형물, 그리고 암모니아를 고농도로 함유하고 있으며 축사의 형태와 계절의 변화에 큰 영향을 받는다. 하수종말처리장 혐기성 소화조 잉여 슬러지에 의한 혐기성 생물반응기의 식종은 효과적이었으며 적응기간은 약 40일 정도 소요되었으나 media로 충전된 필터형 생물반응기인 AF와 이단 ASBF의 적응 속도가 UASB보다 빨랐다. 유입수 T-N 370~800mg/L에서 생물반응기는 77~91% 의 높고 안정된 COD 제거율을 보였으나 유입수 T-N 760~1,310 mg/L에서 COD 제거율은 24~94%로 불안정하였으며 전반적으로 감소되었다. 양돈폐수에 함유된 암모니아는 메탄균에 대한 저해작용을 나타낼 수 있는 충분한 농도이므로 효율적인 혐기성 소화처리를 위하여 전처리로서 암모니아의 제거는 필수적이다. 생물반응기는 $1.1{\sim}2.2kg-COD/m^3{\cdot}d$의 비교적 낮은 OLR에서 COD 제거효율은 78.9~81.5%, 그리고 biogas 발생량은 $0.39{\sim}0.59m^3/kg-COD_r$로 효과적이었으나 유입수 COD의 증가 혹은 HRT 단축운전에 의한 OLR의 증가에 따라 COD 제거효율은 감소하였으며 UASB는 AF와 이단 ASBF보다 COD 제거효율 감소폭이 컸다. AF와 이단 ASBF는 충전된 media와 이단화에 의하여 biomass의 보유능력이 우수하며 높은 OLR에도 안정적이며 높은 COD 제거율올 나타내므로 고농도의 유기물을 함유하며 축사의 형태와 계절에 따라 특성의 변화가 큰 양돈폐수의 처리에 효율적이다.

  • PDF

SBR에서 충격부하에 따른 완충효과 (Buffering effects of shock loads in sequencing batch reactor)

  • 지대현;이광호;이재근
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.581-587
    • /
    • 2008
  • In this study, we investigated the buffering effect with different COD, $NH_4{^+}-N$ and TP shock loads on the performance of lab-scale Sequencing Batch Reactor(SBR) using synthetic wastewater. This study was operated under the following conditions : HRT, 12 hrs : MLSS, 2,000 mg/L : F/M ratio, $0.2kgCOD/kgMLSS{\cdot}d$ : SRT, 20days, and was increased by a factor, COD : ranging from 200-2000 mg/L, $NH_4{^+}-N$ : ranging from 30-300 mg/L, T-P : ranging from 5-50 mg/L in the reactor. As results, COD removal rate at different shock loads was decreased until 42.1%(stable state : 95%) and concentration with effluent was higher than 695 mg/L(at Run 6). In case of $NH_4{^+}-N$ removal rate was decreased until 35.8% from 97.0% and also T-P removal rate was decreased until 5.0%. Effluent concentrations of COD, $NH_4{^+}-N$ and T-P were rapidly increased according to shock loads and needed 3, 4 and 6 additional cycle times for recovering the stable condition.

중성계 및 알칼리성 고화재를 이용한 고화하수슬러지의 복토재가 모형매립조 내 유기물 분해에 미치는 영향 (Effect of Solidified/Stabilized Sewage Sludge using Neutral Solidifying Chemical Agent and Alkaline Agent as Landfill Cover on Decomposition of Organic Matter in Lysimeter)

  • 김혜진;박진규;송상훈;이남훈
    • 대한환경공학회지
    • /
    • 제30권8호
    • /
    • pp.768-774
    • /
    • 2008
  • 하수슬러지 고화물이 매립지에 미치는 영향을 평가하기 위하여 모형매립조 실험을 수행하였다. 모형매립조는 총 3기를 제작하였으며, 충전물질은 퇴비와 사료, 모래를 각각 10 : 10 : 80으로 혼합하여 충전하였고, 복토재는 개발한 중성계 고화제로 하수 슬러지를 고화한 G고화물(LR1), 알칼리성 고화재로 고화한 A고화물(LR2), 마사토(LR3)로 하였다. 이를 30 $\pm$ 2$^{\circ}C$의 항온실에서 약450일 동안 운전한 결과 누적발생가스발생량과 VS성분에 따른 가스발생량, CO$_2$와 CH$_4$의 누적발생량은 LR2 > LR1 > LR3순 나타났다. 그리고 LR1, LR2, LR3의 COD$_{Cr}$변화를 살펴본 결과 LR1의 COD$_{Cr}$농도는 LR3와 같이 지속적으로 감소하는 것으로 나타나 G고화물은 침출수의 COD$_{Cr}$에는 영향을 미치지 않는 것으로 나타났다. LR2는 250일경 재슬러리화되어 COD$_{Cr}$농도가 증가하고 있다. 그리고 T-N, T-P농도에 있어서도 LR3의 농도가 높은 것으로 보아, 하수슬러지고화물 복토에 의한 침출수의 T-N, T-P에는 영향이 미미한 것으로 판단된다.

낙동강 8개 보 인근 수질측정 지점의 4대강 사업 전·후 수질 변동성 분석 (Comparison of Water Quality Before and After Four Major River Project for Water Monitoring Stations Located Near 8 Weirs in Nakdong River)

  • 조현경;임효진;김상민
    • 농업생명과학연구
    • /
    • 제52권6호
    • /
    • pp.89-101
    • /
    • 2018
  • 본 연구는 4대강 사업에 따른 낙동강 수질의 변동성을 평가하기 위한 것으로, 낙동강에 건설된 8개보 건설 전후의 수질을 비교, 분석하였다. 이를 위해 보에서 가장 인접한 상류 수질측정지점을 대상으로 4대강 사업전(2003년 1월부터 2008년 11월), 사업중(2008년 9월부터 2012년 4월), 사업후(2012년 5월부터 2017년 9월)까지의 3개 기간에 대해 DO, BOD, COD, SS, T-N, T-P, TOC 등의 수질자료를 수집하였다. 4대강 사업전후 자료의 유의성 검증을 위해 대응검정 T-test를 95%의 신뢰구간에서 실시한 결과 DO, BOD, COD, T-N, TOC는 사업 전보다 사업 후 수질 농도가 높아지는 경향이 있으며, 그 중 BOD, COD, TOC의 농도가 큰 차이를 보였다. 반면에 SS, T-P는 사업 전보다 사업 후 농도값이 감소하였다. 수질인자 중 변화값이 큰 BOD, COD, TOC를 수질등급으로 나누어 공간적으로 분석해 본 결과 사업전에 비해 사업후의 수질등급이 나빠지는 경향을 보였다.