• Title/Summary/Keyword: $Ar-N_2$ plasma

Search Result 210, Processing Time 0.026 seconds

Selectivity and Permeability Characteristics of Pure CO2 and N2 Gases through Plasma Treated Polystyrene Membrane (플라즈마 처리된 폴리스티렌 막을 통한 순수한 CO2 와 N2 기체의 선택·투과 특성)

  • Hwang, Yui-Dong;Shin, Hee-Yong;Kwak, Hyun;Bae, Seong-Youl
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.588-596
    • /
    • 2006
  • The surface of polystyrene membrane treated by Ar, $O_2$ plasma, and the effects were observed before and after the treatment and permeability of $CO_2$, $N_2$ and selectivity of $CO_2$ relative to $N_2$ was measured using continuous flow gas permeation analyzer (GPA). The mole ratio of O over C in the surface was increased from 0 to 0.179 with Ar plasma treatment and route mean square of surface was increased from $15.86{\AA}$ to $71.64{\AA}$. Therefore the contact angle was decreased from $89.16^{\circ}$ to $18.1^{\circ}$. Thus Plasma treatments made surface of membrane tend to be highly hydrophilic. The optimum condition for the $CO_2$ permeability and ideal selectivity of the plasma treated membrane was as follows: the measurement of Ar (60 W, 2 min, $70^{\circ}C$) plasma treatment was $1.14{\times}10^{-12}[m^3(STP){\cdot}m/m^2{\cdot}sec{\cdot}atm]$ and 4.22. In the case of $O_2$ plasma treatment, the contact angle was decreased at $13.56^{\circ}$ with increase of O/C ratio ($0.189{\AA}$) and route mean square of surface ($57.10{\AA}$). The optimum condition for the $CO_2$ permeability and ideal selectivity of the plasma treated membrane was as follows: the measurement of $O_2$ (90 W, 2 min, $70^{\circ}C$) plasma treatment was $7.1{\times}10^{-12}[m^3(STP){\cdot}m/m^2{\cdot}sec{\cdot}atm]$ and 11.5. After plasma treatment, the changes of membrane surface were all subtly linked with both cross-linking and etching effects. Finally, it was confirmed that the gas permeation capacity and selectivity of the modified membrane with plasma could be improved by an appropriate control of the plasma conditions such as treatment time, the power input and sort of plasma gas.

Electro-optical characteristics of MgO protective layer after RF plasma treatment using Ar, $O_2$ and $H_2$ gases

  • Son, Chang-Gil;Lee, H.J.;Jung, J.C.;Park, W.B.;Moon, M.W.;Oh, P.Y.;Jeong, J.M.;Ko, B.D.;Lee, J.H.;Lim, J.E.;Han, Y.G.;Lee, S.B.;Yoo, N.L.;Jeong, S.H.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1211-1214
    • /
    • 2005
  • One of the important problems in recent AC-PDP technology is high efficiency. In this research, we have been investigated electro-optical characteristics of MgO protective layer after radio frequency(RF) plasma treatment using Ar, $O_2$, and $H_2$ gases. The breakdown voltage order was $O_2$ > Ar > Nontreatment > $H_2$. Also, brightness order was $O_2$ > Ar > Non-treatment > $H_2$. In this experiment, the best result was obtained after $O_2-plasma$ treatment.

  • PDF

Plasma Etching and Polymerization of Carbon Fiber (플라즈마 에칭과 중합에 의한 탄소섬유의 표면 개질)

  • H. M. Kang;Kim, N. I.;T. H. Yoon
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.143-146
    • /
    • 2002
  • Unsized AS-4 carbon fibers were etched by RF plasma and then coated via plasma polymerization in order to enhance adhesion to vinyl ester resin. The gases utilized for the plasma etching were Ar, $N_2 and O_2$, while the monomers used for the plasma polymerization coating were acetylene, butadiene and acrylonitrile. The conditions for the plasma etching and the plasma polymerization were optimized by measuring interfacial adhesion with vinyl ester resin via micro-droplet tests. Among the treatment conditions, the combination of Ar plasma etching and acetylene plasma polymerization provided greatly improved interfacial shear strength (IFSS) of 69MPa compared to 43MPa with as-received carbon fiber. Based on the SEM analysis of failure surface and load-displacement curve, it was assume that the failure might be occurred at the carbon fiber and plasma polymer coating. The plasma etched and plasma polymer coated carbon fibers were subjected to analysis with SEM, XPS, FT-IR or Alpha-Step, and dynamic contact angles and tensile strengths were also evaluated. Plasma polymer coatings did not change tensile strength and surface roughness of fibers, but decreased water contact angle except butadiene plasma polymer coating, possibly owing to the functional groups introduced, as evidenced by FT-IR and XPS.

  • PDF

Study of the Effect of $N_2$ Gas in Etched ZnO Thin Films in $Cl_2$/Ar Plasma ($N_2$ 가스를 첨가한 $Cl_2$/Ar 플라즈마에 의해 식각된 ZnO 박막의 식각 특성)

  • Heo, Gyeong-Mu;Park, Jeong-Su;Ju, Yeong-Hui;Woo, Jong-Chang;Kim, Chang-Il
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.223-224
    • /
    • 2009
  • 본 연구에서는 $Cl_2$/Ar 기반의 플라즈마 식각에 $N_2$가스를 첨가하여 ZnO 박막을 식각 하였을 때 관찰된 ZnO 박막의 식각 특성에 관하여 연구 하였다. ZnO 박막 식각 실험은 RF 800 W, bias power 400 W, 공정 압력 15 mTorr를 기준으로 하였으며 가스 혼합 비율로는 최적의 식각률을 보여주는 $Cl_2$/Ar=8:2 비율에서 실행하였다. 연구의 목적인 첨가 가스 $N_2$$Cl_2$ (80%)/Ar (20)%에 5 sccm 씩 첨가하여 20 sccm 까지 증가 시켜 실험 하였다. $N_2$ 가스가 15 sccm 첨가되었을 때 식각률 95.9 nm/min로 기존 $Cl_2$/Ar 기반의 플라즈마 식각보다 높은 식각률을 보여 주었으며 $N_2$ 가스 흐름 조절 외에도 공정 압력, RF power, bias power를 변경하며 실험하였다. 식각된 ZnO 박막의 표면은 최대 식각률을 보이는 공정 조건을 찾기 위해 surface profiler ($\alpha$-step)을 이용하여 식각률을 측정하였으며 ZnO 박막 표면의 화학적인 변화를 조사하기 위해 x-ray photoelectron spectroscopy (XPS)를 사용하였다. XPS 분석 결과 Zn $2p_{3/2}$ peak 가낮은 binding energy 쪽으로 이동한 것을 관찰 할 수 있었다. 또한 O 1s 의 스펙트럼을 분석한 결과 N-O bond와 O-H bond가 존재함이 밝혀졌다.

  • PDF

The Dry Etching Characteristics of TiO2 Thin Films in N2/CF4/Ar Plasma

  • Choi, Kyung-Rok;Woo, Jong-Chang;Joo, Young-Hee;Chun, Yoon-Soo;Kim, Chang-Il
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.32-36
    • /
    • 2014
  • In this study, the etching characteristics of titanium dioxide ($TiO_2$) thin films were investigated with the addition of $N_2$ to CF4/Ar plasma. The crystal structure of the $TiO_2$ was amorphous. A maximum etch rate of 111.7 nm/min and selectivity of 0.37 were obtained in an $N_2/CF_4/Ar$ (= 6:16:4 sccm) gas mixture. The RF power was maintained at 700 W, the DC-bias voltage was - 150 V, and the process pressure was 2 Pa. In addition, the etch rate was measured as functions of the etching parameters, such as the gas mixture, RF power, DC-bias voltage, and process pressure. We used X-ray photoelectron spectroscopy to investigate the chemical state on the surface of the etched $TiO_2$ thin films. To determine the re-deposition and reorganization of residues on the surface, atomic force microscopy was used to examine the surface morphology and roughness of $TiO_2$ thin films.

Dry Etching Characteristics of TiN Thin Films in BCl3-Based Plasma

  • Woo, Jong-Chang;Park, Jung-Soo;Kim, Chang-Il
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.3
    • /
    • pp.106-109
    • /
    • 2011
  • We investigated the etching characteristics of titanium nitride (TiN) thin film in $BCl_3$/Ar inductively coupled plasma. The etching parameters were the gas mixing ratio, radio frequency (RF) power, direct current (DC)-bias voltages and process pressures. The standard conditions were as follows: total flow rate = 20 sccm, RF power = 500 W, DC-bias voltage = -100 V, substrate temperature = $40^{\circ}C$, and process pressure = 15 mTorr. The maximum etch rate of TiN thin film and the selectivity of TiN to $Al_2O_3$ thin film were 54 nm/min and 0.79. The results of X-ray photoelectron spectroscopy showed no accumulation of etch byproducts from the etched surface of TiN thin film. The TiN film etch was dominated by the chemical etching with assistance by Ar sputtering in reactive ion etching mechanism, based on the experimental results.

Development of High Density Inductively Coupled Plasma Sources for SiH4/O2/Ar Discharge (고밀도 유도 결합 플라즈마 장치의 SiH4/O2/Ar 방전에 대한 공간 평균 시뮬레이터 개발)

  • Bae, S.H.;Kwon, D.C.;Yoon, N.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.5
    • /
    • pp.426-434
    • /
    • 2008
  • A space averaged $SiH_4/O_2/Ar$ simulator for the high density inductively coupled plasma sources for $SiH_4/O_2/Ar$ discharge is developed. The developed simulator uses space averaged fluid equations for electrons, positive ions, negative ions, neutral species, and radicals in $SiH_4/O_2/Ar$ plasma discharge, and the electron heating model including the anomalous skin effect. Using the developed simulator, the dependency of the density of charged particles, neutral particles, and radicals, the electron temperature, the plasma resistance, and the power absorption coefficient for the RF power and pressure is calculated.

Characteristics of Diamond Like Carbon Film Fabricated by Plasma Enhanced Chemical Vapor Deposition Method with mixed Ar, N2 gas rate (혼합된 Ar, N2 가스 유량에 따른 PECVD 방법에 의하여 제작된 다이아몬드 상 탄소 박막의 특성)

  • Gang, Seong-Ho;Kim, Byeong-Jin;Bae, Gyeong-Tae;Ju, Seong-Hu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.87-87
    • /
    • 2018
  • 다이아몬드 상 탄소(diamond-like carbon, DLC)는 상당량의 $sp^3$ 결합을 가지는 비정질 탄소(a-C) 또는 수소화 비정질 탄소(a-C:H)로 이루어진 준안정 형태의 탄소이다. DLC는 전기 저항과 굴절률이 높고 화학적으로 다른 물질과 반응하지 않으며, 마찰계수가 낮고 경도가 높아 자기 디스크, 광학 소자 등의 다양한 분야에서 적용되고 있다[1,2]. 또한 다이아몬드에 비해 상온에서 성장이 가능할 정도로 합성온도가 낮아 적용 기판의 제한이 거의 없고, 증착 방법과 조건에 따라 탄소 결합의 다양성과 비정질성이 변화하기 때문에 넓은 범위의 특성을 얻을 수 있는 장점이 있다. 지금까지 DLC 박막의 광학적 특성, 특히 굴절률, 광학적인 에너지 밴드 갭, 자외선과 적외선 투과성에 대해서는 많은 연구가 진행되었으나 가시광선의 투과성에 대한 연구는 제한적이며[4], 가시광선 투과도 개선에 대한 연구는 전무하다. 본 연구에서는 ITO 기판 위에 DLC를 합성하고 기계적 특성과 가시광선 영역 투과도를 조사하였다. RF-PECVD(radio frequency plasma enhanced chemical vapor deposition) 방법에 의해서 $C_2H_2+Ar$ 혼합 가스 비율과 $C_2H_2+N_2$ 혼합 가스 비율을 변화시켜 ITO 기판 위에 DLC 박막을 합성하였다. 공정 압력과 rf-power, 증착시간, 기판온도는 0.2 torr, 40 W, 5 분, $50^{\circ}C$로 고정하고, 공정 가스는 $C_2H_2+Ar$$C_2H_2+N_2$가 200 sccm이 되도록 비율을 변화하였다. $C_2H_2:Ar$$C_2H_2:N_2$의 비율은 180 : 20, 160 : 40, 140 : 60, 120 : 80, 100 : 100이 되도록 가스의 유량을 조절하였다. 투과도는 가시광선(380 ~ 780 nm) 범위에서 측정하였고 두께와 표면조도는 AFM으로 측정하였다. 투과도는 $C_2H_2+Ar$의 Ar 가스 비율이 증가할수록 증가해 140 : 60일 때 최댓값을 나타낸 후 다시 감소하였다. $C_2H_2+N_2$ 투과도는 $N_2$ 가스 비율이 증가할수록 감소하는 경향을 나타내었다. 표면 거칠기는 $C_2H_2+Ar$ 혼합 가스를 사용한 경우의 Ar의 가스 비율이 증가할수록 증가하였다. 그러나 $C_2H_2+N_2$ 혼합 가스를 사용한 경우에는 $N_2$ 가스의 혼합 비율이 증가할수록 감소하였다.

  • PDF

Frequency effect of TEOS oxide layer in dual-frequency capacitively coupled CH2F2/C4F8/O2/Ar plasma

  • Lee, J.H.;Kwon, B.S.;Lee, N.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.284-284
    • /
    • 2011
  • Recently, the increasing degree of device integration in the fabrication of Si semiconductor devices, etching processes of nano-scale materials and high aspect-ratio (HAR) structures become more important. Due to this reason, etch selectivity control during etching of HAR contact holes and trenches is very important. In this study, The etch selectivity and etch rate of TEOS oxide layer using ACL (amorphous carbon layer) mask are investigated various process parameters in CH2F2/C4F8/O2/Ar plasma during etching TEOS oxide layer using ArF/BARC/SiOx/ACL multilevel resist (MLR) structures. The deformation and etch characteristics of TEOS oxide layer using ACL hard mask was investigated in a dual-frequency superimposed capacitively coupled plasma (DFS-CCP) etcher by different fHF/ fLF combinations by varying the CH2F2/ C4F8 gas flow ratio plasmas. The etch characteristics were measured by on scanning electron microscopy (SEM) And X-ray photoelectron spectroscopy (XPS) analyses and Fourier transform infrared spectroscopy (FT-IR). A process window for very high selective etching of TEOS oxide using ACL mask could be determined by controlling the process parameters and in turn degree of polymerization. Mechanisms for high etch selectivity will discussed in detail.

  • PDF