• 제목/요약/키워드: $18^{\circ}C$ Thermal Environment

Search Result 60, Processing Time 0.027 seconds

Effect of Annealing Treatment Conditions on the Interfacial Adhesion Energy of Electroless-plated Ni on Polyimide (고온열처리 조건이 무전해 니켈 도금막과 폴리이미드 사이의 계면접착력에 미치는 영향)

  • Park, Sung-Cheol;Min, Kyoung-Jin;Lee, Kyu-Hwan;Jeong, Yong-Soo;Park, Young-Bae
    • Korean Journal of Materials Research
    • /
    • v.18 no.9
    • /
    • pp.486-491
    • /
    • 2008
  • The effect of annealing treatment conditions on the interfacial adhesion energy between electrolessplated Ni film and polyimide substrate was evaluated using a $180^{\circ}$ peel test. Measured peel strength values are $26.9{\pm}0.8,\;22.4{\pm}0.8,\;21.9{\pm}1.5,\;23.1{\pm}1.3,\;16.1{\pm}2.0\;and\;14.3{\pm}1.3g/mm$ for annealing treatment times during 0, 1, 3, 5, 10, and 20 hours, respectively, at $200^{\circ}C$ in ambient environment. XPS and AES analysis results on peeled surfaces clearly reveal that the peeling occurs cohesively inside polyimide. This implies a degradation of polyimide structure due to oxygen diffusion through interface between Ni and polyimide, which is also closely related to the decrease in the interfacial adhesion energy due to thermal treatment in ambient conditions.

A Study on Development of Freshwater Fish Shelter and Evaluation of Water Quality for the Reduction of Thermal Stress in Shallow Pond (얕은 연못에서 담수 어류의 열성 스트레스 저감을 위한 피난처 개발 및 수질환경 조사 연구)

  • Lee, Saeromi;Ahn, Chang Hyuk;Joo, Jin Chul;Song, Ho Myeon;Park, Jae Roh
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.12
    • /
    • pp.828-836
    • /
    • 2014
  • The purpose of this study evaluates the water quality of artificial deep pool (ADP) during the late spring and summer. we monitored the water quality, as pH, dissolved oxygen (DO), temperature and conductivity at two stations (St. 1. open water, St. 2. in the ADP). The water quality in the ADP is very stable, and temperature and DO are lower than the open water (average value; temperature $1.4{\sim}3.2^{\circ}C$, DO 2.4~3.6 mg/L). In particular, daily variation of temperature in the open water showed above $4^{\circ}C$, but ADP remained stable. The water quality was analyzed using two-way analysis of variance (ANOVA). The results of the analysis showed difference about temperature, pH, DO, conductivity (two-way ANOVA, p<0.05). The ADP has created an aqua environment in thermal and DO gradients by depth. About 1.2 m, Temperature and DO were sharply decreased. The Rhodeus uyekii is dominant species in pond of this study. The ADP offers optimum water temperature ($16.5{\sim}18.5^{\circ}C$) to the Rhodeus uyekii about spawning. Consequently, the ADP offers stable habitat than open water for fish and aquatic organisms during the summer. It is also a good shelter for fish from a thermal stress.

A Field Measuring Study on the Thermal Environment of Human Surrounding in the Classroom Equipped with Ceiling Unit (천장형 유닛을 설치한 교실 내의 인체 주변 온열환경에 관한 실측연구)

  • Cho Sung-Woo;Im Young-Bin;Lee Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.240-246
    • /
    • 2006
  • This paper performed to investigate on vertical temperature distribution, effective draft temperature (ETD) and PMV (Predicted Mean Vote) in the classroom, which is located YangSan city (Kyungsangnam-Do), Korea, is equipped with ceiling unit. The vertical temperature difference between F.L+10 cm (ankle) and F.L+120 cm (neck) of a measuring point which is adjacent corridor in the classroom showed about $1^{\circ}C$ but of measuring point which is adjacent outdoor expressed up to $4^{\circ}C$, The effective draft temperature (ETD) is -2.3 and -0.52 and 0.67 at near ceiling unit but is 1.2 and 3.3 at far from ceiling unit. The PMV of total classroom showed the range of 'Cold' and 'Slightly Cold.' Therefore, to achieve comfort condition in the classroom is equipped with ceiling unit, the location of ceiling unit and discharge angle and discharge distance from ceiling unit are very important elements.

Studies on the Thermal and Rheological Properties of Polypropylene/Starch-MB Blends (폴리프로필렌/옥수수전분 블렌드의 열적 유변학적특성 연구)

  • Kim, Youn Cheol;Lee, Chang-Young
    • Applied Chemistry for Engineering
    • /
    • v.18 no.6
    • /
    • pp.557-561
    • /
    • 2007
  • Polypropylene (PP)/corn starch master batch (starch-MB) blends with different PP compositions of 40, 50, 60, and 80 wt% were prepared by melt compounding at $200^{\circ}C$, using lab scale Brabender mixer. The chemical structures and thermal properties of the PP/starch-MB blends were investigated by FT-IR, differential scanning calorimetry (DSC), and thermogravimetric analyzer (TGA). The chemical structure was confirmed by the existence of hydroxy group. There was no district change in melting temperature and melting enthalpy, and TGA curve indicated a decrease in degradation temperature with starch-MB content. The porosity change of blend was measured by scanning electron microscope (SEM), the degree of porosity on the blend surface increased with the starch-MB content. The rheological properties indicated an increase in complex viscosity, shear thinning tendency and elasticity with the starch-MB concentration. These effects were confirmed by an oscillatory viscometer at $200^{\circ}C$. From these results, it is found that 40 wt% is the optimum starch-MB concentration. The fiber was fabricated from PP60/MB40 with 40 wt% starch-MB and the porosity and tensile properties were investigated.

Analysis of the efficiency of natural ventilation in a multi-span greenhouse using CFD simulation (CFD 시뮬레이션을 이용한 연동형 온실 내 자연환기의 효율성 분석)

  • Short, Ted H.
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 1999
  • Natural ventilation in a four and one-half span, double polyethylene commercial greenhouse was investigated with actual data collected at Quailcrest Farm near Wooster, Ohio. Moreover, a computational fluid dynamics (CFD) numerical technique, FLUENT V4.3, was used to predict natural ventilation rates, thermal conditions, and airflow distributions in the greenhouse. The collected climate data showed that the multi-span greenhouse was well ventilated by the natural ventilation system during the typical summer weather conditions. The maximum recorded air temperature difference between inside and outside the greenhouse was 3.5$^{\circ}C$ during the hottest (34.7$^{\circ}C$) recorded sunny day; the air temperatures in the greenhouse were very uniform with the maximum temperature difference between six widely dispersed locations being only 1.7$^{\circ}C$. The CFD models predicted that air exchange rates were as high as 0.9 volume per minute (A.C. .min$^{-1}$ ) with 2.5m.s$^{-1}$ winds from the west as designed.

  • PDF

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

A Study on the Preparation of the Dimensionally Stable Anode(DSA) with High Generation Rate of Oxidants(I) (산화제 생성율이 높은 촉매성 산화물 전극(DSA)의 개발에 관한 연구(I))

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.18 no.1
    • /
    • pp.49-60
    • /
    • 2009
  • Fabrication and oxidants formation of 1 and 2 component metal oxide electrode, which is known to be so effective to destruct non-biodegradable organics in wastewater, were studied. Five electrode materials (Ru, Pt, Sn, Sb and Gd) were used for the 1 and 2 component electrode. The metal oxide electrode was prepared by coating the electrode material on the surface of the titanium mesh and then thermal oxidation at $500^{\circ}C$ for 1 h. The removed RhB per 2 min and unit W for one component electrode decreased in the following sequences: Ru/Ti>Sb/Ti>Pt/Ti>Gd/Ti>Sn/Ti. The concentration of oxidants generated in 1 and 2 component electrodes was in the order of: $ClO_2$> free Cl>$H_2O_2>O_3$. OH radical was not generated from in entire one and two component electrodes. RhB degradation rate and generated oxidants of the Ru-Sn=9:1 electrode was higher than that of the two component electrode. The exact relationship between the removal of RhB and the generated oxidants concentration was not obvious. However, it was assumed that electrode with high RhB decolorization had high oxidant concentration.

Fabrication of Polycrystalline Si Films by Silicide-Enhanced Rapid Thermal Annealing and Their Application to Thin Film Transistors (Silicide-Enhanced Rapid Thermal Annealing을 이용한 다결정 Si 박막의 제조 및 다결정 Si 박막 트랜지스터에의 응용)

  • Kim, Jone Soo;Moon, Sun Hong;Yang, Yong Ho;Kang, Sung Mo;Ahn, Byung Tae
    • Korean Journal of Materials Research
    • /
    • v.24 no.9
    • /
    • pp.443-450
    • /
    • 2014
  • Amorphous (a-Si) films were epitaxially crystallized on a very thin large-grained poly-Si seed layer by a silicide-enhanced rapid thermal annealing (SERTA) process. The poly-Si seed layer contained a small amount of nickel silicide which can enhance crystallization of the upper layer of the a-Si film at lower temperature. A 5-nm thick poly-Si seed layer was then prepared by the crystallization of an a-Si film using the vapor-induced crystallization process in a $NiCl_2$ environment. After removing surface oxide on the seed layer, a 45-nm thick a-Si film was deposited on the poly-Si seed layer by hot-wire chemical vapor deposition at $200^{\circ}C$. The epitaxial crystallization of the top a-Si layer was performed by the rapid thermal annealing (RTA) process at $730^{\circ}C$ for 5 min in Ar as an ambient atmosphere. Considering the needle-like grains as well as the crystallization temperature of the top layer as produced by the SERTA process, it was thought that the top a-Si layer was epitaxially crystallized with the help of $NiSi_2$ precipitates that originated from the poly-Si seed layer. The crystallinity of the SERTA processed poly-Si thin films was better than the other crystallization process, due to the high-temperature RTA process. The Ni concentration in the poly-Si film fabricated by the SERTA process was reduced to $1{\times}10^{18}cm^{-3}$. The maximum field-effect mobility and substrate swing of the p-channel poly-Si thin-film transistors (TFTs) using the poly-Si film prepared by the SERTA process were $85cm^2/V{\cdot}s$ and 1.23 V/decade at $V_{ds}=-3V$, respectively. The off current was little increased under reverse bias from $1.0{\times}10^{-11}$ A. Our results showed that the SERTA process is a promising technology for high quality poly-Si film, which enables the fabrication of high mobility TFTs. In addition, it is expected that poly-Si TFTs with low leakage current can be fabricated with more precise experiments.

The Effects of Winch-curtain Ventilation on the Indoor Environment of a Fattening Swine House (윈치커튼 환기가 비육돈사의 실내 환경에 미치는 영향)

  • Kim, Hyeon-Tae;Song, Jun-Ik;Choi, Hong-Lim
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The study was conducted to investigate the effects of climate on indoor environment of a swine house with natural. This study was tested in the beef swine stall at Young-in, Kyung-ki do. The test was experimented for the effect of interior environment by the outdoor environment and the interior-pan. The results are as follows. 1. In test 1 ($T_{out}$ : $25.7^{\circ}C$, without fan), an indoor air flow pattern was showed that entered from sidewall winch-curtain to went out of a indoor by the ridge winch-curtain. And the velocity of a section of the center was measured two times as large as the velocity of the floor. It is the acceleration of the velocity by thermal buoyancy. And, the entered air was rapidly dissipated by flow energy. So that in the swain livestock with sidewall winch-curtain is effected by thermal buoyancy. And the air temperature of the indoor was distributed more higher as compared with the outdoor temperature. This result is caused by the sensible heat from swine and the ventilation is restricted. 2. In test 2 (($T_{out}$ : $25.7^{\circ}C$, with fan), the velocity of a section of the center was measured more higher as compared with the test 1. And the variance of air velocity was distributed higher as compared with the test 1. This result is showed dead region of air flow with a fan operation. And, the variance of gas density was distributed lower as compared with the test 1.

Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer (사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가)

  • Park, Su-Jin;Jung, Sun-Young;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.