• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.022 seconds

A Nuclear Medicine Study on the Effect of High Energy Gamma Irradiation on Rabbit Liver (고(高)에너지 방사선(放射線) 조사(照射)가 가토(家兎) 간장(肝臟)에 미치는 영향(影響)에 관(關)한 핵의학적(核醫學的) 연구(硏究))

  • Lee, Joon-Il;Min, Bong-Hee
    • Journal of radiological science and technology
    • /
    • v.12 no.1
    • /
    • pp.3-16
    • /
    • 1989
  • In order to investigate the in vivo effect of $^{60}Co$ radiation on rabbit liver, the uptake ratio and regional excretory value in hepatocytes and Kupffer cells were estimated during acute and chronic hepatic injuries. The left lobe of liver was irradiated at 15 Gy or 30 Gy with a single dose and subsequent changes were analysed with a seial nuclear medicine imaging by using $^{99m}Tc-phytate,\;^{99m}Tc-DISIDA\;and\;^{99m}Tc-HSA$ and resulting data were computerized. The degree of hepatic damage, duration of the injury, and recovery pattern after the irradation were in agreement with the findings of other investigations. However, out values were more quantitative evacuation than those of other publications. Recovery of decreased uptake of $^{99m}Tc-phytate$ was delayed approximately $2{\sim}3$ days later than that of $^{99m}Tc-DISIDA$. In acute radiation induced injury, the results demonstrated that the recovery of Kupffer cells was delayed more than that of hepatocytes. This discrepancy was considered due to the differences in repair activities between these cell types. The decreased of regional excretory value in irradiated area was found to be dose-dependent but had no corelation with regional uptakes of DISIDA and phytate. The decreased of regional excretory value observed in non-irradiated region suggested that irradiated liver might induce an indirect effect.

  • PDF

The Research on the Simultaneous Examination of Thyroid Uptake Measurement and Thyroid Scan using Attenuation Filter (감쇄필터를 이용한 갑상선섭취율 측정과 갑상선스캔의 동시검사법 연구)

  • Lee, Hyo-Yeong;Kim, Jong-Eon;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.309-313
    • /
    • 2011
  • It is necessary for patients to wait twice for the thyroid examination of thyroid uptake measurement and thyroid scan by using $^{99m}Tc$-pertechnetate. In the study, a method of simultaneous examination of thyroid uptake measurement and thyroid scan by one intravenous injection of $^{99m}Tc$-pertechnetate was suggested by using attenuation filter. As a result, there was a significant correlation between control group and experimental group according to existence of attenuation filter. Consequently, the simultaneous examination of thyroid uptake measurement and thyroid scan by one intravenous injection can be applied clinically.

$^{99m}Tc-HMPAO$ Regional Cerebral Blood Flow SPECT in Transient Ischemic Attacks (일과성 뇌허혈 발작 환자에 있어서 $^{99m}Tc-HMPAO$ 국소 뇌혈류 SPECT의 유용성)

  • Ahn, Myeong-Im;Park, Young-Ha;Lee, Sung-Yong;Chung, Soo-Kyo;Kim, Jong-Woo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.149-154
    • /
    • 1989
  • Transient ischemic attacks (TIAs) is a syndrome resulting from brain ischemia lasting less than 24 hours. The mechanisms of TIAs may be similar to those of cerebral embolism and thrombosis, and thus TIAs may be followed by cerebral infarction. Despite the availability of CT scanning, the diagnosis and management of TIAs continue to be difficult. Recently SPECT has been advocated as a diagnostic imaging modality. We performed Tc-99m-HMPAO regional cerebral blood flow (rCBF) SPECT in 24 patients with the clinical diagnosis of TIAs to assess its ability to detect early changes of rCBF, and determine the diagnostic value. Ten men and fourteen women with an average of 51 years (range; 27-74 years) were included. All but 8 patients had normal brain CT prior to SPECT. The two patients had moderate degree of brain atrophy and the 6 patients nonspecific calcifications. Eighteen of the 24 patients had abnormal Tc-99m-HMPAO rCBF SPECT. Fifteen had unilateral involvement and the other three had bilateral involvements. Seventy-five percents of the defects were found in the left cerebral hemisphere. According to the distribution of the lesions (total number: 34 lesions), fourteen were in the parietal, eight in the temporal, and the remainders were elsewhere. Tc-99m-HMPAO rCBF SPECT is sensitive in detecting rCBF abnormalities in patients with TIAs, and represent the most accurate diagnostic tool available in the diagnosis of TIAs.

  • PDF

A Case of Thymoma Misdiagnosed as Parathyroid Adenoma on Tc-99m pertechnetate/Tl-201 Subtraction Scintigraphy (Tc-99m pertechnetate/Tl-201 감영 신티그라피에서 부갑상선 선종으로 오인된 흉선종 1예)

  • Chung, Yong-An;Yoo, Ie-Ryung;Kim, Sung-Hoon;Chung, Soo-Kyo;Wang, Young-Pil;Jung, Ji-Han;Lee, Kyo-Young;Kim, Byung-Kee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.274-279
    • /
    • 2001
  • A large superior mediastinal mass was found incidentally by ultrasonography in a 60-year-old man. There was an abnormal accumulation of Tl-201 in the lower pole of left thyroid gland, extending into left superior mediastinum on Tc-99m pertechnetate/Tl-201 subtraction scan. Laboratory findings relating thyroid and parathyroid were all within normal range. We considered the mass as a non-functioning parathyroid adenoma tentatively. However, subsequent surgery and pathologic examination revealed the mass to be a benign mixed thymoma. We report a case of patient with thymoma showing unusual Tc-99m pertechnetate/Tl-201 subtraction imaging and laboratory findings, and suggest to consider the possibility of other mediastinal tumors rather than parathyroid adenoma.

  • PDF

Clinical Significance of the $^{99m}Tc-HIDA$ Cholescintigraphy in the Neonatal Jaundice (신생아 황달에서 $^{99m}Tc-HIDA$ 스캔의 임상적 의의)

  • Park, Nan-Jea;Kwon, In-Soon;Kwon, Jung-Sik;Kim, Myung-Duk;Lee, Myung-Chul;Cho, Bo-Yeon;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.1
    • /
    • pp.71-78
    • /
    • 1983
  • Twenty-nine patients with neonatal jaundice were evaluated with $^{99m}Tc-HIDA$ cholescin-tigraphy to elucidate its clinical applicability. Scintigraphic results were interpreted by the degree of early hepatic uptake and the presence or absence of radioactivity in the G-I tract. The results are as follows; I) In 18 patents with neonatal hepatitis; 8 of 11 patients with decreased hepatic uptake and all 5 patients with good hepatic uptake showed G-I radioactivity. But, the 2 remainders with poor hepatic extraction were not available for evaluation of neonatal jaundice due to patient's poor hepatic function. 2) In 9 patients, confirmed as biliary obstruction; all showed no G-I radioactivity but 3 of the 9 showed poor hepatic extraction on scan and they were not available for evaluation. 3) All the 2 patients with postoperative cholangitis showed G-I radioactivity on $^{99m}Tc-HIDA$ scan. 4) Relationship between histopathologic findings and $^{99m}Tc-HIDA$ scan; Among 5 patients with biliary cirrhosis 3 showed poor hepatic extraction, the remainders showed decreased and good hepatic uptake respectively. But, the 2 portal fibrosis without cirrhosis and 4 cholestasis showed decreased (4) or good hepatic uptake (2).

  • PDF

Clinical Characteristies and Findings of $^{99m}Tc$-MIBI Heart SPECT in Patients with Acute Myocardial Infarction with Normal Coronary Arteriography (정상 관동맥 조영상을 갖는 급성 심근경색증 환자의 임상적 특징 및 $^{99m}Tc$-MIBI심근 SPECT 소견)

  • Park, Myung-Jae;Choi, Tae-Youl;Kim, Deog-Yoon;Kang, Heung-Sun;Choue, Chung-Whee;Kim, Kwon-Sam;Kim, Kwang-Won;Kim, Myung-Shick;Song, Jung-Sang;Bae, Jong-Hoa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.65-70
    • /
    • 1993
  • Among 64 patients with acute myocardial infarction who underwent coronary angiogrphy, 7 patients (10.9%) showed normal coronary artery. Six patients were men and 1 patient was female. The mean age of patients were $31.1{\pm}3.9$ years. Among the risk factors of coronary heart disease, smoking was most probable factor in patients with acute myocardial infarction with normal coronary angiography. $^{99m}Tc$-MIBI heart SPECT performed 5 of 7 patients and showed that it could be used in diagnosis, localization, extent of infarct area in patients with acute myocardial infarction with normal coronary angiograpy. But follow up $^{99m}Tc$-MIBI heart SPECT study will be needed to define the ability of myocardial viability in this patients.

  • PDF

The Effect of Calcitonin in the Rat Osteoporosis Induced by the Immobilization and Long-term Glucocorticoid Use (장기간의 dexamethasone투여 및 편측 하지 고정에 의한 골조송증에서 calcitonin의 작용)

  • Lim, Sang-Moo;Hong, Sung-Woon;Lee, Jin-Oh;Kang, Tae-Woong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.108-118
    • /
    • 1990
  • It is well known that the glucocorticoid suppresses the osteoblast and the calcitonin suppresses the osteoclast. If the calcitonin prevents the osteoporosis with increased Tc-99m MDP uptake in the long-term use of glucocorticoid, then the calcitonin has some activating effect on the bone formation. The immobilization operation was done on the left hind-leg of 16 male Sprague-Dawley rats weighing about 300 g each. For 12 weeks after operation,8 rats were injected 0.5 mg/kg dexamethasone, and the other 8 rats were injected 0.5 mg/kg dexamethasone and $1\;\bar{u}/kg$ eel calcitonin. The bone mineral content was measured by the single photon absorptiometry and the Tc-99m MDP uptake was used as an index of the osteoblastic activity. 1) The Tc-99m MDP uptakes in the dexamethasone treated group were lower than those in the dexamethasone and calcitonin treated group, and there was no significant difference in Tc-99m MDP uptakes between the immobilized and normal femurs. 2) The bone mineral contents in the dexamethasone treated group were significantly lower than in the dexamethasone and calcitonin treated group, and the immobilized femurs had tower BMC than normal femurs. 3) The slope of regression between the BMC and Tc-99m MDP uptake was stiff in the dexamethasone treated group, and flat in the dexamethasone and calcitonin group, which shows discrepancy between the bone resorption and formation resulting prevention of net bone loss in the dexamethasone and calcitonin treated group. In conclusion, the calcitonin has some effect on the bone formation, and further studies with urinary hydroxyproline and cyclic AMP are expected.

  • PDF

Comparison of Radioactivity Measurement with Radionuclide Calibrators in Nuclear Medicine Centers (의료용 방사능측정기의 측정 정확도 평가)

  • Son, Hye-Kyung;Kim, Ji-Hye;Lim, Chun-Il;Yang, Hyun-Kyu;Park, Ki-Jung;Oh, Heon-Jin;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.16-21
    • /
    • 2010
  • To acquire good image quality and to minimize unnecessary radiation dose to patients, it is important to ensure that the radiopharmaceutical administered is accurately measured. Quality control of radionuclide calibrators should be performed to achieve these goals. The purpose of this study is to support the quality control of radionuclide calibrators in nuclear medicine centers and to investigate the level of measurement accuracy of the radionuclide calibrators. 58 radionuclide calibrators from 45 nuclear medicine centers, 74 radionuclide calibrators from 58 nuclear medicine centers, and 60 radionuclide calibrators from 45 nuclear medicine centers were tested with I-131, Tc-99m and I-123, respectively. The results showed that 81% of calibrators for I-131, 61% of calibrators for Tc-99m and 67% of calibrators for I-123 were within ${\pm}5%$. 17% of calibrators for I-131, 20% of calibrators for Tc-99m and 15% of calibrators for I-123 had a deviation in the range 5%< $|{\Delta}|{\leq}10%$. 2% of calibrators for I-131, 19% of calibrators for Tc-99m and 18% of calibrators for I-123 had a deviation of $|{\Delta}|$ >10%. Follow-up measurements were performed on the calibrators whose error exceeded the ${\pm}10%$ limit. As a result, some of the calibrator showed an improvement and their deviation decreased below the ${\pm}10%$ limit. The results have shown that such comparisons are necessary to improve the accuracy of the measurement and to identify malfunctioning radionuclide calibrators.

Evaluation on the Usefulness of Filter in Sentinel Lymphoscintigraphy Using $^{99m}Tc$-Phytate (Phytate를 이용한 감시림프절 검사 시 Filter의 유용성 평가)

  • Jeong, Yeong-Hwan;Seo, Han-Kyung;Shim, Cheol-Min;Lim, Seong-Dong;Han, Dong-Hyeon;Park, Yung-Sun;Kim, Dong-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.35-39
    • /
    • 2010
  • Purpose: The aim of this study was to investigate distribution of particle size in phytate kit and compare filtered method with non-filtered method using 200 nm filter for sentinel lymphoscintigraphy (SLS). Materials and Methods: Five phytate kit of having the same available period was measured by particle size analyzer. For in-vivo experiment, $^{99m}Tc$-phytate was injected intradermally at both foot to perform lymphoscintigraphy. Imaging was acquired at 1hour after injection. Region of interest (ROI) was drawn in inguinal and background area for analysis. RAW 264.7 cells (Murine macrophage cell) were prepared for measurement of celluar uptake as a representative of macrophages. Paired t-test was performed using SPSS (SPSS Inc, USA) for statistical analysis. Results: The size of most particle in Techne phytate kit was distributed in 130~650 nm(90.5 %). In-vivo study, the ROI analysis showed similar result between filtered and non-filtered sample, and the numerical value of count/pixel were $58.3{\pm}5.97$ and $60.2{\pm}4.88$. In-vitro study, cellular uptake study also showed no difference between filtered and non-filtered sample by gamma counting. Conclusion: The present study demonstrates that there was no meaning of 200 nm filtered method for SLS using $^{99m}Tc$-phytate.

  • PDF

Effects of Use of the Iodine Contrast Medium on Gamma Camera Imaging (요오드 조영제 사용이 감마카메라 영상에 미치는 영향)

  • Pyo, Sung-Jae;Cho, Yun-Ho;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.557-564
    • /
    • 2016
  • Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficient in an SPECT/CT attenuation correction will be considered herein. For experimental materials used $^{99m}TcO_4$ 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of $^{99m}TcO_4$. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope $^{99m}TcO_4$ and the saline solution were mixed. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and saline solution, the mean counting rate without correction by the CT absorption coefficient is $182{\pm}26counts$, while the counting rate with correction by the CT absorption coefficient is $531.3{\pm}34counts$. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were $166{\pm}29$, $158.3{\pm}17$, $154{\pm}36$, and $150{\pm}33counts$ depending on the densities of the contrast medium, while the mean values after attenuation correction were $515{\pm}03$, $503{\pm}10$, $496{\pm}31$, and $488.7{\pm}33counts$, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of dignosis.