• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.025 seconds

Myocardial Uptake of Tc-99m MDP in Chronic Renal Failure With Cardiomyopathy (심근증이 동반된 만성 신부전 환자에서 Tc-99m MDP의 심근 섭취)

  • Kim, Seung-Eun;Sohn, Hyung-Sun;Chung, Yong-An;Park, Young-Ha;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.260-263
    • /
    • 2000
  • A uremic patient on hemodialysis, who had concurrent cardiomyopathy showed intense myocardial uptake of $^{99m}Tc$-methylene diphosphonate (MDP). The presumed cause of uptake in the myocardium is metastatic calcification due to hypercalcemia secondary to the renal failure. However, supplementary mechanism caused by cardiomyopathy should be considered. We describe a case with bone tracer uptake in the myocardium in the absence of infarction in a patient with chronic renal failure.

  • PDF

A Study of Bone Scan Time by Use of $^{99m}Tc-MDP$ ($^{99m}Tc-MDP$를 이용한 Bone scan 시간(時間)에 관(關)한 고찰(考察))

  • Park, Soung-Ock;Lee, Hyun-Bae
    • Journal of radiological science and technology
    • /
    • v.17 no.1
    • /
    • pp.77-86
    • /
    • 1994
  • The bone scan reflects the metabolic reaction of bone to a disease process, whether neoplastic, traumatic or inflammatory. In normal bone tissue, the labeled diphosphate complexes accumulate in the perivascular fluid next to the marrow cavity at the interface between uncalcified and calcified bone matrix. HMDP has the most rapid plasma clearance among the commonly used diphosphonate followed by MDP and then HEDP. I have studied about bone scan time by use of $^{99m}Tc-MDP$, and got 336 images from 112 patients. The result obtained as follow; 1. Accumulation rate of $^{99m}Tc-MDP$ is higher than other age groups in below 30-year old group. 2. Accumulation rate, in 10year old group, is 75.85% on 120min. but other groups are most high on 180 min. 3. The density differants between bone and soft tissue increased with time. 4. Image contrast is good in younger group than old.

  • PDF

Scintigraphic Detection of Elbow Hygroma in a Dog Using $^{99m}Tc-MDP$ (개에서 $^{99m}Tc-MDP$를 이용한 주관절 수활액낭종의 핵의학적 진단)

  • 강성수;김중현;배춘식;최석화
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.465-468
    • /
    • 2001
  • Elbow hygroma and hypertrophic osteodystrophy were diagnosed in Doberman referred to Veterinary Teaching Hosptial of Chungbuk national University. Physical examination, plain radiography, and bone scan were performed in the patient. The radiography revealed soft tissue swelling on the caudal region of the elbow and irregular radiolucent zone involving the metaphysis subjacent and parallel to the distal radial and ulnar physes. The bone scan of the forelimbs revealed increased uptake in region where the soft, fluid-filled mass on the elbow was present. But the radiolucent areas (the distal radial and ulnar physes) were seen normal bone uptake. Therefore, hypertrophic osteodystrophy ruled out the diagnosis. $^{99m}Tc-MDP$ scan is suitable to routine clinical use for soft tissue inflammation and bone lesions detection.

  • PDF

A Study of Counting Efficiency according to the Window-width on Radionuclides $^{131}I$ and $^{99m}Tc$ (방사성(放射性) 의약품(醫藥品) $^{131}I$$^{99m}Tc$에서 window폭(幅) 변화(變化)에 따른 계수(計數)의 변화비교(變化比較)에 관(關)한 검사(檢討))

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.9 no.1
    • /
    • pp.65-71
    • /
    • 1986
  • It is an experimental report about optimum window-width on radionuclides $^{99m}Tc$ and $^{131}I$ and obtained results as follows; 1. In case of $^{99m}Tc$, a) The difference of counting rate in each window-width is greater at the below 20% window than above 20% window-width. b) BKG counting is proportionated to the window-width. 2. In case of $^{131}I$, a) The counting rate increased according to the window-width but the increasing course is not equal in all window. The difference of counting rate is greater at the below of 20% window-width than above 20% window. b) BKG counting is proportionated to the window-width.

  • PDF

Multifocal Peritoneal Splenosis in Tc-99m-Labeled Heat-Denatured Red Blood Cell Scintigraphy (Tc-99m-가열처리 적혈구 스캔에서 다발성 복막비증)

  • Yoon, Min-Ki;Hwang, Kyung-Hoon;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.190-191
    • /
    • 2006
  • A 44-year-old man with a past medical history of splenectomy came to hospital because of epigastric pain. Abdominopelvic computed tomography(CT) showed a soft tissue mass and multifocal variable-sized nodules as well as findings suggestive of cholecystitis. Subsequently, he underwent Tc-99m-labeled heat-denatured red blood cell(RBC) scintigraphy to evaluate the mass and nodules. The scintigraphy confirmed multifocal peritoneal splenosis in the abdominopelvic cavity.

The analysis of difference in the relative renal function based on total counts method and average counts method (총 계수 분석법과 평균 계수 분석법에 따른 신장 기능의 차이 분석)

  • JUNG WOO-YOUNG;CHO SHEE-MAN;PARK SEUNG-YONG;SHIM DONG-OH
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2003
  • Purpose : $^{99m}Tc-DMSA$ renal scan can be used in the evaluation of relative renal function and some anatomy. The relative renal function can be assess by measurement of $^{99m}Tc-DMSA$ uptake by the individual kidney. Renal counts

  • PDF

An Artifact Caused by Using the Inadequate Acquisition Parameter in Tc-99m ECD Brain Perfusion SPECT (Tc-99m ECD 뇌혈류 SPECT 시행시 부적절한 영상획득 모수에 의한 인공산물)

  • Seo, Han-Kyung;Kim, Min-Woo;Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.540-542
    • /
    • 2004
  • Although artifacts in tomographic imaging can arise from a number of sources, this case presents an artifact caused by using inadequate acquisition parameters which do not match the collimator with which a camera equipped in Tc-99m ECD brain SPECT. Whenever the collimator in tomographic studies is changed, we should take care to use suitable parameters of acquisition protocol according to the collimator with which a camera is fitted. Other ways to prevent an error of this type is to use a point source.

Significant Reperfusion on $^{99m}Tc-HMPAO$ SPECT in a Case of Subacute MCA Infarction (한의학적 치료로 $^{99m}Tc-HMPAO$ SPECT상 현저한 재관류를 보인 아급성기 중대뇌동맥경색 환자 1례)

  • Park, Jung-Mi;Jung, Woo-Sang;Seo, Al-An
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.437-442
    • /
    • 2001
  • For ischemic cerebrovascular disease, it is well known that early luxury perfusion is related to a good clinical outcome and single photon emission computed tomography(SPECT) has the potential for providing useful information about regional cerebral blood flow. We report one case of Rt. MCA infarction mainly treated by oriental medicine and revealed luxury perfusion without thrombolysis. In acute stage, neurological deficits of the patient were very severe. 99mTc-HMPAO SPECT images obtained 10days after the attack showed large perfusion defect in the Rt. MCA territory. We followed up 99mTc-HMPAO SPECT 40days after the ictus. Despite of the poor early perfusion, we found considerably improved perfusion and neurological improvement.

  • PDF

Extraosseous Uptake of Ureteral Transitional Cell Cancer on $^{99m}Tc-MDP$ Bone Scan (뇨관(尿管) 이행세포암종(移行細胞癌腫)에 $^{99m}Tc-MDP$가 섭취(攝取)된 1예(一例))

  • Ahn, Il-Min;Rhim, Sang-Moo;Sohn, In;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Kim, Kyung-Do
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.1
    • /
    • pp.79-82
    • /
    • 1982
  • A case of extraosseous uptake of ureteral transitional cell Cancer on $^{99m}Tc-MDP$ bone scan was experienced. The Hot spot seemed to be caused by the tumor uptake of $^{99m}Tc-MDP$ ifself.

  • PDF

Lung and Stomach Uptake of $^{99m}Tc-MDP$ in Diffuse Lymphoma (골신티그램상 폐와 위에 방사능 집적을 보인 미만성 임파종)

  • Byun, Jae-Young;Kim, Sung-Hoon;Chung, Soo-Kyo;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.221-224
    • /
    • 1987
  • Uptake of $^{99m}Tc$ bone-scanning agents by extra osseous tissues has been frequently reported. However, lung and stomach uptake of $^{99m}Tc$ bone-scanning agents in lymphoma has been rarely described. We report here a case with lymphoma and hypercalcemia which showed diffuse uptake of $^{99m}Tc-MDP$ by lung and stomach.

  • PDF