갑상선암 환자의 방사성옥소 치료 후 타액선 기능의 변동 (The Change of the Salivary Function after the High Dobe Radioiodine Treatment in the Patients with Differentiated Thyroid Cancer)

  • 임상무;홍성운;이진오;강태웅
    • 대한핵의학회지
    • /
    • 제23권1호
    • /
    • pp.7-12
    • /
    • 1989
  • The pain, swelling of salivary glands and dry mouth are not infrequent complication of the high dose radioiodine treatment in the patients with differentiated thyroid cancer. The purpose of this study was, by the dynamic salivary scintigraphy, to observe the change of the salivary function after the high dose $(150\sim200mci)$ radioiodine treatment. From May 1987 to April 1988, the dynamic salivary scintigraphy with 5mci of $^{99m}Tc-pertechnetate$ and gamma camera was performed before and 7 days after the radiolodine treatment in 7 patients with differentiated thyroid cancer. Just after the dynamic scintigraphy, the stimulation test with vitamin C solution of pH3.0 and poststirnulation scintigraphy were done, and the radioactivity uptake index, excretion fraction and salivary clearance after the stimulation were calculated for each gland. There was positive correlation between the radioactivity uptake index and excretion fraction after the stimulation. The salivary clearance after the stimulation was $18.96{\pm}8.95ml/min$ in the pretreatment state, and $14.37{\pm}7.7ml/min$ after the radioioine treatment. After the radioiodine treatment, the radioactivity uptake index, excretion fraction and salivary clearance after the stimulation were significantly reduced in the parotid glands, but only the excretion fraction was reduced in the submandibular glands. The more the pretreatment salivary clearance after the stimulation was, the % change after the treatment was smaller. Further studies on the relation between the radiation dose in the salivary glands and the change of their function, and the long-term observation for the recovery of function are expected.

  • PDF

이동형 감마프로브 개발과 기본성능 평가 (Development of Portable Gamma Probe and Its Basic Performance Test)

  • 김희중;곽철은;최용;양묘근;봉정균;이상철
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.216-219
    • /
    • 1997
  • We are developing a portable multipurpose gamma counting and imaging probe that will be useful for many applications in nuclear medicine including radioimmunoguided surgery in the detection and treatment of malignant tumors. Any diagnostic information provided by CT, MRI, PET, SPECT or gamma camera imaging prior to surgery obviously is very important, but current techniques are limited in many instances. To overcome some of these limitations, the portable multipurpose gamma probe is being developed. The gamma probe consists of NaI(Tl) crystal with 1" dia $\times$ 0.5" thick and singlechannel photomultiplier tube (SC-PMT) for counting, and 3" dia $\times$ 0.375" and multichannel photomultiplier tube (MC-PMT) for imaging, nuclear instrument module (NIM), position circuits, interface, and PC. The energy resolution using Tc-99m was measured as 14% and the spatial resolution using 3mm dia green LED was measured as 2.9mm. These priliminary results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine.

  • PDF

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

3상 골신티그램을 이용한 급성 일과성 활막염의 진단 (Three-Phase Bone Scintigraphic Diagnosis of Acute Transient Synovitis)

  • 정수교;이명희;김춘열;박용휘
    • 대한핵의학회지
    • /
    • 제19권1호
    • /
    • pp.73-75
    • /
    • 1985
  • Acute transient synovitis of the hip presents clinically pain and limping. But in the majority of the cases, definite positive findings are not manifest in roentgenogram in its early phase. However radionuclide bone imaging combines with the assessment of vascularization and bone tracer uptake is of great value in solving this diagnostic problem. The materials for this study consisted of 29 children with acute transient synovitis of the hip, characterized by symptoms and physical signs of an arthritis, negative X-ray findings and disappearance of all symptoms and signs within a short period of time. They were twenty males and 9 females and age ranged from 1 to 12 years. We took pelvic reontgenogram in AP and frog-leg views. After intravenous bolus injection of 10 to 15 mCi of $^{99m}Tc-methylene$ diphosphonate, 24 sequential image of the pelvis was taken at 2-second interval for blood flow study. The scintigrams were made using a gamma camera with high resolution parallel hole collimator. Blood pool imaging was obtained at 2 minutes after tracer administration. After 3 hours, static images were taken and then closeup image of the hip using pin-hole collimator was followed. The results were as follows: 1) Bone scintigram was much more sensitive than conventional roentgenogram in diagnosis of acute transient synovitis of the hip. 2) Three-phase imagings showed increased vascular activities in blood pool scintigrams in 96%. 3) Pin-hole imaging showed increased tracer uptake in the regional bones of the hip, par ticularly in the medial aspect of femoral head and acetabulum. 4) We confirmed that three-phase imaging reinforced with pin-hole technique were very useful in diagnose of acute transient synovitis of the hip.

  • PDF

간혈관신티그램의 정상성과 간암 및 간농양에서의 변화 (Hepatoscintiangiography of Normal Liver and Its Alteration in Hepatomas and Liver Abscess)

  • 박용휘;정수교
    • 대한핵의학회지
    • /
    • 제20권1호
    • /
    • pp.25-31
    • /
    • 1986
  • This study was performed to establish normal hepatoscintiangiographic(HSA) pattern of hepatic blood flow and to investigate dynamic differential HSA findings of primary and metastatic carcinomas and abscess of the liver. HSA was carried out after intravenous bolus injection of 10 mCi of Tc-99m-phytate by obtaining sequential anterior images of 1-second exposure for 16 seconds. Observations included (1) baseline study of normal hepatic blood flow pattern by correlating with contrast angiogram, (2) time sequence phasing of normal HSA, and (3) analysis of altered patterns in primary and metastatic carcinomas and abscesses of the liver. Materials consisted of 20 normal subjects, 28 primary hepatocellular carcinomas, 16 metastatic carcinomas and 7 liver abscesses. Results were: (1) Normal HSA demonstrated 3 distinct phases of arterialization(AP), of arterial hepatogram(AHP), and of portal venous hepatogram(PVHP). The means of each phase were 5.3, 6.3 and 8.3 seconds, respectively. Portal vein could be seen in all but one of 20 normal subjects. (2) Pattern changes in diseases groups were early start of AP in carcinomas and very early start of AP in abscesses. AP became prolonged in all disease group. (3) Distinction between AHP was sharp in metastasis and abscesses but un sharp in primary hepatoma. Cold area or areas became vascularized in primary hepatoma but not in abscess. Cold areas of metastasis were inhomogeneously vascularized in late AP and throughout AHP and became relatively vascular as PVHP began. The cold area of abscess showed rim enhancement during AH and APH. These differences in HSA pattern were very useful in differential diagnosis of the diseases studied.

  • PDF

뇌졸중 환자의 퇴원 후 재입원에 영향을 미치는 요인: 후향적 연구 (Factors Affecting Readmission After Discharge in Stroke Patients: A Retrospective Study)

  • 강애정;이송희;김녹범;전미양
    • Journal of Korean Biological Nursing Science
    • /
    • 제24권4호
    • /
    • pp.262-271
    • /
    • 2022
  • Purpose: The purpose of this study was to identify the factors affecting readmission in stroke patients. Methods: A retrospective study design was used. Participants were 3,675 adult cerebral stroke patients in the inpatient wards of the Department of Neurology and Neurosurgery of G University Hospital located in C city. Data were collected from January 1, 2016 to December 31, 2021 and data were analyzed using χ2 test, independent t-test, and multivariate logistic regression with SPSS/WIN 24.0. Results: After discharge for stroke, the readmission rate was 23.7%, and the mortality rate was 0.3%. The variables with significant differences between the readmission group and non-readmission group were age, type of stroke, surgery, ICU treatment, mRS score, blood pressure, diabetes, and heart disease. Factors influencing an readmission in stroke patients were Age 65-74 (OR 1.30, 95% CI=1.03-1.64), ≥ 75 (OR 1.28, 95% CI=1.02-1.62), mRS score 2points (OR 2.50, 95% CI=1.99-3.13), HTN status (OR 1.26, 95% CI=1.07-1.50), CVD status (OR 1.38, 95% CI=1.01-1.90), TC (OR 1.60, 95% CI=1.05-2.44). Conclusion: To lower the readmission rate of stroke patients, it is essential to control lifestyle, including whether or not to take treatment drugs, after diagnosing risk factors such as high blood pressure, diabetes, and heart disease, hyperlipidemia. Nursing interventions that can provide information on risk factor management and coping strategies are urgently needed as symptoms change. In addition, research is needed to develop and implement an intervention strategy that can improve the function of stroke patients as much as possible at home or in society so that they can lead an independent life without the help of others, and verify their effectiveness.

게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구 (Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography)

  • 정지욱;이효영;윤종준;이화진;이무석;송현석;박세윤;김재환
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.150-154
    • /
    • 2010
  • 심장기능을 평가하는데 중요한 기준이 되는 심박출계수의 측정은 반복검사가 용이한 심초음파가 가장 흔히 사용되고 있다. 현재 게이트심장혈액풀스캔의 검사 빈도가 낮고 게이트심장혈액풀 SPECT를 이용한 좌심실 심박출계수의 결과는 게이트심장혈액풀스캔과 심초음파의 결과와 비교적 잘 맞는 것으로 알려져 있으나 임상적으로는 잘 이용되지 못하고 있다. 이에 본 연구에서는 게이트심장혈액풀스캔 및 SPECT에서의 심박출계수를 심초음파와 비교하여 분석하였다. 2007년 1월부터 2010년 5월까지 34명의 환자를 대상으로 심초음파 검사 후 게이트심장혈액풀스캔과 SPECT를 함께 시행하였다. 대상 환자 가운데 남자가 23명이었고 여자는 11명이었으며 평균연령은 $52.6{\pm}27.2$세였다. 환자에게 생리식염수로 희석한 pyrophosphate 1 cc를 먼저 정맥주사하고 15분 후 20 mCi의 $^{99m}{TcO_4}^-$를 정맥주사 하였다. 10분 후 안정 상태에서 심전도를 부착한 뒤 planar와 SPECT를 연속하여 촬영하고 ADAC Laboratories, Ver. 4.20 software를 이용하여 영상을 분석하고 각각의 심박출계수를 측정하였다. 일원배치 분산분석(one-way anova) 후 사후검정(Tukey test)을 통해 평균값을 비교하고 서로 간 pearson 상관계수를 구하였다(SPSS Ver 17.0). 심박출계수의 평균값과 표준편차값은 planar에서 $56.3{\pm}13.9$ (%), SPECT에서 $60.4{\pm}16.0$ (%), 심초음파에서는 $59.1{\pm}14.4$ (%)로 유의한 차이는 없었으며(p=0.486) 이에 대한 사후 검정은 planar-심초음파 p=0.697, SPECT-심초음파 p=0.928, planar-SPECT p=0.469로 유의한 차이가 없었다. 상관관계에서는 planar-심초음파 r=0.801, SPECT-심초음파 r=0.810, planar-SPECT r=0.873 비교적 높은 상관관계를 보였다(p<0.01). 게이트혈액풀스캔 및 SPECT와 심초음파를 이용하여 구한 좌심실의 심박출계수는 높은 상관성을 보였으며 평균값에서도 유의한 차이는 없었다. 현재 게이트혈액풀스캔은 시행건수가 줄어들고 스캔의 정확성이나 재현성에 대한 문제는 남아있으며 SPECT의 경우 임상적으로 잘 적용되지 못하고 있으나 다양한 심기능 지표들을 얻을 수 있고 혈액풀스캔에서의 심박출계수와 좋은 일치율을 보이므로 심초음파를 대체할 수 있는 유용한 검사법이라 생각된다.

  • PDF

뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가 (Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image)

  • 이충운;유연욱;김용근;원우재
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.23-27
    • /
    • 2018
  • [목적] 뼈 검사는 골격계 질환에 대한 예민도와 높은 해상력의 핵의학 영상 검사이다. 본 연구는 추가적인 방사선피폭없이 뼈 검사 영상과 골반 X선 영상의 결합을 시행하고 영상의 해부학적 정보와 관용도를 증가시켜 환자 병변 진단에 도움이 되고자 한다. 2015년 11월에서 2016년 8월까지 본원에서 뼈 검사를 실시한 환자 중 골반 X선 촬영을 시행한 236명을 대상으로 진행하였다.(남자 64명, 여자 172명, 평균연령 $50.96{\pm}15.39$세) 검사장비는 감마카메라 Symbia Ecam(SIEMENS, Germany)을 사용하였고 디지털 엑스레이는 DRS-800(Listem, Korea)을 사용하였다. 영상의 결합 및 분석프로그램은 Osirix version 3.8.1(Osirix, USA), 통계프로그램은 Stata/SE 버전 14.0(StataCorp, USA)를 사용하였다. 환자에게 $^{99m}Tc-DPD$ 740 MBq을 정맥주사한 후 2~4시간이 지난 뒤에 검사를 진행하였다. 감마카메라 영상 획득 조건은 Matrix size $256{\times}1024$, Zoom 1.00, 검사 속도 17 cm/min로 하였다. 디지털 엑스레이는 Collimator size $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp(60~97kVp), 평균 30 mAs(20~48)로 전상장골극과 치골결합 사이 수직입사를 하였다. Osirix 상에서 골반 뼈의 윤곽 및 가상의점을 선택하여 결합하고 획득한 영상을 핵의학과 5년 이상 근무한 방사선사 3명에 의해 평가 되었으며, 모두 동일할 경우 일치, 하나라도 동일하지 않을 경우 불일치로 평가하였다. 전체 236명 중 일치하는 대상은 216명 (91.53%) 이다. 연령의 중위수 및 범위(최소값~최대값)는 일치하지 않는 그룹에서 67(46~81)세, 일치하는 그룹에서 52(22~87)세로, 일치하지 않는 그룹의 연령이 더 높은 것을 확인하였고, 두 군 간에 연령이 다른지 Wilcoxon rank-sum test를 수행해 본 결과, 통계적으로 유의하게 두 군 간에 나이가 차이나는 것을 확인할 수 있었다(p < 0.0001). 남자는 64명 중 60명(93.75%), 여자는 172명 중 156명(90.70%)가 일치하였고, 골반 병변이 없던 환자는 54명 중 54명(100.00%), 골반 병변이 있던 환자는 182명 중 162명(89.01%) 일치하였고, 골반 병변 여부에 따른 일치율은 통계적으로 유의한 차이를 보였다(p = 0.0094). 뼈 검사와 골반 X선 영상을 결합하는데 있어서 여러 가지 변수가 있을 수 있었고 환자의 연령과 골반병변이 영상의 결합에 일부 영향을 줄 수 있을 것으로 생각된다. 본 연구를 통하여 방사선 피폭 없이 소아의 골반 골육종 진단에 도움이 되리라 사료되고 이와 같은 영상의 결합 연구를 통해서 핵의학 영상발전에 도움이 될 것으로 기대된다.

스캔 시간의 결정시기에 따른 총 스캔 시간 변화에 관한 연구 (The Change of Total Scan Time in Accordance with the Time of the Decision of Scan Time)

  • 이종훈;류재광;정우영
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.81-85
    • /
    • 2009
  • 목적 : 핵의학 검사에는 동일한 목적부위에 시간경과에 따른 변화를 관찰하고, 일정시간 동안에 여러 번 나누어 영상을 획득하는 검사들이 많이 있다. 이 때 동일한 영상 획득 조건이 적용되어야만 한다. Hepatobiliary scan, lung scan 등의 검사는 시간 간격을 두고, 여러 번의 영상을 획득하는 검사이다. 해당 검사 별로 최초의 영상에서 설정된 계수를 획득하기 위해 소요되는 시간을 연속되는 다음의 영상에 동일하게 적용하는 pre-set time을 설정한다. 이 때 각각의 영상에서 동일한 검사 시간이 적용되어야 한다. 이 연구는 pre-set time을 적용하는 검사에 스캔 시간의 결정시기에 따라 스캔 시간의 변동을 분석하고 이에 대한 합리적인 대안을 찾으려 한다. 실험재료 및 방법 : 2009년 1월부터 2009년 3월까지 서울아산병원 핵의학과에서 방사성의약품 $^{99m}Tc$-mebrofenin을 이용한 간담도 검사를 대상으로 하였다. 환자에게 222 MBq (6mCi)를 정맥주사한 후 5분이 지난 뒤에 스캔을 시작하였다. 두 개의 검출기를 서로 마주보게 하여, 환자가 양쪽 검출기 사이에서 erect position을 유지하도록 하였고 환자는 복부 전면을 검출기에 최대한 밀착하였다. 스캔을 시작한 후 총 검사시간의 10%, 25%, 50%, 75%일 때 예상 검사 종료 시간을 측정하였다. 이 측정시간을 스캔이 모두 끝난 후에 최종 검사시간과 검사 도중 예상되는 스캔 시간을 비교하였다. 그리고 팬텀을 이용하여 선량에 따른 시간 변화를 관찰하였다. 결과 : 스캔을 시작하고 스캔 시간이 총 예상 스캔 시간의 10% 되었을 때, 25% 되었을 때, 50% 되었을 때, 75% 되었을 때의 차이는 10%일 때 최대 5초 이상의 시간차이를 보였으며, 25% 되었을 때(t:2.88, p<0.01)와 50%가 되었을 때 (t:2.05, p<0.01) 통계적으로 유의한 차이가 있었다. 결론 : 스캔이 모두 종료된 후에 스캔 시간을 결정하는 것이 가장 정확한 측정치를 가지지만, 실무현장에 적용에는 다소간의 어려운 점이 있었다. 이것은 정량분석이 필요한 검사에 부정확한 결과치를 초래 할 수 있고, 이를 개선하려는 검사자의 노력이 필요한 것으로 판단된다. 스캔을 시작하고 최소한 총 스캔시간의 약 50% 이상이 지난 후에, 총 스캔시간을 결정하는 것이 영상간의 불일치하는 스캔시간으로 유발되는 정량 분석 오차를 최소화 할 수 있다는 것을 의미한다.

  • PDF

NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구 (The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera)

  • 오주영;강천구;김정열;박훈희;오기백;김재삼
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권4호
    • /
    • pp.291-297
    • /
    • 2013
  • 본 연구는 NaI (Tl) 신틸카메라를 이용하여 동적영상 분석에서 계수율 오차가 $T_{1/2}$에 미치는 영향을 알아보고, 이에 대한 점 선원을 이용한 정도관리 방법을 제안하는 것에 목적을 두었다. 18.5 MBq 부터 185 MBq 까지 2 mL 용량의 $^{99m}TcO_4^-$을 주사기에 넣어 점 선원을 제작한 후, Infinia(GE, USA) 감마카메라를 이용하여 10초부터 60초까지 각각 30프레임의 동적영상을 획득하였다. 두 번째 실험으로 5대의 감마카메라(Infinia 2대, Forte 2대, Argus 1대)를 대상으로, 74 MBq의 점 선원으로 90프레임의 동적영상을 획득하였다. 첫 번째 실험의 평균계수율을 10초 단위로 비교한 결과 18.5 MBq부터 92.5 MBq까지의 선원은 10초/프레임에서 60초/프레임까지 평균계수율 간에 유의한 차이를 보이지 않았지만(p>0.05), 111 MBq 이상의 점 선원을 60초/프레임에서 계수율이 유의하게 적게 획득되었다(p<0.01). 이에 따라 5대의 감마카메라에서 90분간 획득한 계수율을 선형 회귀분석한 결과, 4번 감마카메라의 계수 효율은 0.0064%로 가장 낮았고, 경사도와 변동 계수는 각각 0.0042, 0.229로 가장 높게 측정 되었다. 계수율을 카이제곱검정한 결과에서는 비정상적인 요동을 확인하지 못하였고(p>0.02), 분산의 동질성 검정에서 또한 모든 감마카메라의 계수율 간에는 등분산성이 확인되었다(p>0.05). 상관분석에서는 유일하게 계수 효율과 경사도간에 유의한 음의 상관관계가 있는 것으로 분석 되었다(r=-0.90, p<0.05). 마지막으로 -2.5%부터 +2.5%까지 경사도를 변화하여 $T_{1/2}$의 오차를 산출한 결과, $T_{1/2}$이 길수록, 경사도가 높을수록 오차가 커지는 것으로 나타났다. 경사도가 가장 높았던 4번 카메라에서 측정된 수치를 이 결과에 미루어 보았을 때 $T_{1/2}$ 60분까지는 오차가 발생되지 않았다. 결론적으로 의료분야에 사용되는 신틸레이션 감마카메라에 있어 방사선 계수에 대한 엄격한 정도관리가 필요하다고 생각된다. 특히 본 연구에서 계수율이 시간에 따라 변화하는 경향이 파악되었고, 이는 $T_{1/2}$에 영향을 줄 수 있음을 증명하였다. 또한 국내 의료 목적의 신틸레이션 카메라의 계수율에 관한 권고치나 제한치가 없는 점을 미루어 볼 때, 본 연구와 같은 적절한 팬텀 및 관리법의 개발이 필요하다 사료된다.