• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.023 seconds

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Pulmonary Embolism In Childhood Minimal Change Nephrotic Syndrome (소아 미세변화 신증후군에서 폐색전증에 대한 연구)

  • Sung, Seung-Joon;Hong, Ki-Woong;Kim, Eun-Ryoung;Kim, Il-Soo;Cho, Byung-Soo
    • Childhood Kidney Diseases
    • /
    • v.5 no.2
    • /
    • pp.100-108
    • /
    • 2001
  • Purpose : We investigated the incidence and predisposing factors of pulmonary embolism in minimal change nephrotic syndrome(MCNS). Methods : Lung perfusion scan using 99mTC-MAA were done on 14 patients who were diagnosed to minimal change nephrotic syndrome. Group h: Five patients who had perfusion defects on scan, Group B; Nine patients who had no perfusion defect on scan. Between the two groups, the differences of platelet number, hematocrits, albumin, cholesterol, triglyceride, proteinuria were evaluated. Results : Five patients were found to have perfusion defect consistent with pulmonary embolism($35.7\%$). However, there were minimal or no respiratory symptoms and signs. In our laboratory studies, the mean proteinuria on admissions was $676{\pm}31\;mg/m2/hr$ in the group with pulmonary embolism, and $313{\pm}28\;mg/m2/hr$ in the group without pulmonary embolism. There were more severe proteinuria in group with pulmonary embolism(P<0.05). The mean platelet count at early stage of remission after steroid treatment was $746,600{\pm}280,000/mm3$ in the group with pulmonary embolism, $511,890{\pm}90,000/mm3$ in the group without pulmonary embolism. There were significant difference of platelet count between the two groups(P<0.01). In patients with pulmonary embolism, there were more higher and sustained increasement of platelet count. All cases of pulmonary embolism were treated with dipyridamole(5 mg/kg). In 4 cases the perfusion defects were improved in two weeks, however, one case showed persistent perfusion defect after 1 month. Conclusion : Our study suggested that pulmonry embolism might be one of tile major complications in childhood MCNS The occurrence rate was correlated with severity of proteinuria before treatment and sustained increasement of platelet counts in early remission state after steroid treatment. Therefore, the scintigraphic pulmonary perfusion study is mandatory in childhood MCNS, especially in the high risk patients, such as the patients with severe proteinuria and sustained increasement of platelet count. (J Korean Soc Pediatr Nephrol 2001;5 : 100-8)

  • PDF

Development of Evaluation Method of Regional Contractility of Left Ventricle Using Gated Myocardial SPECT and Assessment of Reproducibility (게이트 심근 SPECT를 이용한 좌심실의 국소탄성률 평가방법 개발 및 재현성 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Kang, Won-Jun;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.355-363
    • /
    • 2003
  • Purpose: Regional contractility can be calculated using the regional volume change of left ventricle measured by gated myocardial SPECT image and curve of central artery pressure obtained from radial artery pressure data. In this study, a program to obtain the regional contractility was developed, and reproducibility of regional contractility measurement was assessed. Materials and Methods: Seven patients(male:female=5:2, $58{\pm}11.9$ years) with coronary artery diseases underwent gated Tc-99m MIBI myocardial SPECT twice without delay between two scans. Regional volume change of left ventricle was estimated using CSA (Cardiac SPECT Analyzer) software developed in this study. Regional contractility was iteratively estimated from the time-elastance curve obtained using the time-pressure curve and regional time-volume curve. Reproducibility of regional contractility measurement assessed by comparing the contractility values measured twice from the same SPECT data and by comparing those measured from the pair of SPECT data obtained from a same patient. Results: Measured regional contractility was $3.36{\pm}3.38{mm}Hg/mL$ using 15-segment model, $3.16{\pm}2.25{mm}Hg/mL$ using 7-segment model, and $3.11{\pm}2.57{mm}Hg/mL$ using 5-segment model. The harmonic average of regional contractility value was almost identical to the global contractility. Correlation coefficient of regional contractility values measured twice from the same data was greater than 0.97 for all models, and two standard deviations of contractility difference on Bland Altman plot were 1.5%, 1.0%, and 0.9% for 15-, 7-, and 5-segment models, respectively. Correlation coefficient of regional contractility values measured from the pair of SPECT data obtained from a same patient was greater than 0.95 for all models, and two standard deviations on Bland Altman plot were 2.2%, 1.0%, and 1.2%. Conclusion: Regional contractility of left ventricle measured using developed software in this study was reproducible. Regional contractility of left ventricle will be a new useful index for myocardial function after analysis of the clinical data.

An Evaluation by TSH Radioimmunoassay on Familial Thyroid Disorders (가족 발생적인 갑상선이상의 방사성면역 측정법에 의한 TSH 평가)

  • Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 1989
  • The occurrence of thyroid disorders is connected with iodine deficiency, defective synthesis or releasing of thyroid hormone and endemicity. Genetic factors are known as a single gene defects, interaction of multiple genes with environmental factors, as well as chromosomal aberrations. Diofnosis thyroid disorders is enforced by I-131 uptake test, thyroid scanning with I-131 or Tc-99 m and serum radioimmunoassays of T3, T4, free T4 and TSH. They were largely classified as hypothyroidism, hyperthyroidism, simple goiter and normal. The pedigree of 58 families was drawn by propositus, and then the correlation between thyroid disorders and TSH levels was analyzed. The results are as follows: 1) The offsprings and their mothers of 15 families were hypothyroidism, THS level was 5 folds for offsprings and 4 folds for mothers in comparison with control group. 2) 13 families were hyperthyyroidism in siblings but their mothers were normal in thyroid function, TSH level of the siblings was lower than control group. 3) Though the offsprings and their mothers of 10 families were similar to TSH level of control group, they are all simple goiter, familial thyroid disorders, in other thyroid function test. The familial thyroid disorders suggested that these transmitted from mothers to offsprings with X-linked dominant or autosomal dominant inheritance.

  • PDF

Study on Confirmation of Solid-Meal Lag Phase of Gastric Emptying (고형음식물 위배출시 초기 정체기의 존재에 대한 연구)

  • Lee, Ji-Young;Lee, Kyoung-Soo;Kim, Chang-Guhn;Juhng, Seon-Kwan;Won, Jong-Jin;Nah, Yong-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.207-210
    • /
    • 1991
  • The purpose of this study was to examine the existence of a lag phase of gastric emptying of solid meals. We studied solid phase gastric emptying in 26 normal subject using continuous data aquisition for 30 minutes. Each ingested a 300 g meal containing $^{99m}Tc-labeled$ scrambled egg (solid 150g, milk 150 ml). Lag phase was determined by 1) inspection of the gastric emptying curve 2) time to a 2% decrease in stomach activity 3) the time of visual appearance of duodenal activity on computer image We concluded that solid meal lag phase exist.

  • PDF

Three Cases of Thyroid Hemiagenesis (갑상선 일측 무형성증 3예)

  • Kim, Ki-Hyun;Chung, Hyun-Pil;Kim, Jae-Wook;Koh, Yoon-Woo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.22 no.2
    • /
    • pp.183-187
    • /
    • 2006
  • Thyroid hemiagenesis is a very rare congenital anomaly in which one thyroid lobe fails to develop. The cause of thyroid hemiagenesis is still unknown. The true prevalence of thyroid hemiagenesis is not known, but it is estimated to be from 0.05% to 0.2% in normal children. Thyroid hemiagenesis is common in female with the left lobe being absent. The common disease in the remaining lobe is hyperthyroidism, benign adenoma, a toxic multinodular goiter, chronic thyroiditis, primary myxedema, and rarely carcinoma. Tc-99m pertechnate scintigraphy, ultrasonography and computerized tomography can be used to confirm this anomaly. Here we report three cases with left lobe agenesis. Two of them were euthyroid state while the other hypothyroid patient had a ectopic lingual thyroid.

Evaluation of Cardiac Function Using Radioisotope before and after Open Heart Surgery -Detection of Preoperative Cardiac Shunt and Postoperative Remnant Shunt by Nuclear Angiocardiography- (개심술 전후 방사성 동위원소를 이용한 심기능 평가에 관한 연구 -수술전 shunt 의 진단 및 교정수술후의 성적평가에 대하여-)

  • 서경필
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.194-203
    • /
    • 1982
  • In this investigation we undertook to evaluate the utility of radionuclide cardiac angiography in the detection of cardiac shunts before and after surgical correction. Time-activity curves of ventricles and lungs were evaluated after bolus intravenous injection of 99mTc-human serum albumin in 512 preoperative patients and 551 post-operative patients. Omitting 31 cases of technical failure due to poor bolus, we detected shunts in 459 cases of 481 preoperative evaluations, so the detectability was 95.4%. The cases which couldn`t be detected by this method had small amount of shunt. Also the degree of shunt detected by radioisotope methods were well correlated with oxymetry method. [r=0.89, p<0.01 ] In postoperative evaluations, 18 out of 411 patients with left to right shunt and 10 out of 140 right to left shunt were found to have remnant shunts with radionuclide cardiac angiography. Of the 28 cases with failed operation, 2 were confirmed in reoperation, 2 by cardiac catheterization, 2 by two -dimensional echocardiography. All except one .f these patients had membranous ventricular septal defects and those with left to right shunts had moderate to severe pulmonary hypertension and shunt amount. Also those had larger septal defects than control group. We consider that radionuclide cardiac angiography is a simple and noninvasive method which can show the preoperative diagnosis and postoperative follow up of cardiac shunts.

  • PDF

A Novel In Situ Gel Formulation of Ranitidine for Oral Sustained Delivery

  • Xu, Haoping;Shi, Min;Liu, Ying;Jiang, Jinling;Ma, Tao
    • Biomolecules & Therapeutics
    • /
    • v.22 no.2
    • /
    • pp.161-165
    • /
    • 2014
  • The main purpose of this study was to develop a novel, in situ gel system for sustained delivery of ranitidine hydrochloride. Ranitidine in situ gels at 0.2%, 0.5%, and 1.0% gellan gum concentration (w/v) were prepared, respectively, and characterized in terms of preparation, viscosity and in vitro release. The viscosity of the gellan gum formulations in solution increased with increasing concentrations of gellan gum. In vitro study showed that the release of ranitidine from these gels was characterized by an initial phase of high release (burst effect) and translated to the second phase of moderate release. Single photon emission computing tomography technique was used to evaluate the stomach residence time of gel containing $^{99m}Tc$ tracer. The animal experiment suggested in situ gel had feasibility of forming gels in stomach and sustained the ranitidine release from the gels over the period of at least 8 h. In conclusion, the in situ gel system is a promising approach for the oral delivery of ranitidine for the therapeutic effects improvement.

Effects of Repeated Sympathetic Blocks for Reflex Sympathetic Dystrophy Syndrome -A Case Report- (반사상 교감 신경 위축 증후군에 대한 교감신경 차단효과 -증례 보고-)

  • Bae, Woon-Ho;Roh, Seon-Ju;Goh, Joon-Seock;Min, Byung-Woo
    • The Korean Journal of Pain
    • /
    • v.3 no.2
    • /
    • pp.165-171
    • /
    • 1990
  • The reflex sympathetic dystrophy syndrome (RSDS) consists of sustained burning pain and tenderness, vasomotor instabilitiy, swelling, occasional functional instability, trophic skin change and edema of extremity following trauma, peripheral nerve injury, spinal cord injury, infection, burn and other etiologic factors. The most important thing in RSDS is to start the treatment as soon as the disease was diagnosed. Most patients with RSDS respond dramatically and permanently to sympathetic blocks if treatment is instituted before irreversible trophic changes. The characteristic radiological finding in RSDS is a patchy osteoporosis in the cancellous bone. Periarticular hyperactivity is seen in RSDS by Tc99m bone scan. We have managed 4 cases of RSDS. The methods of management and effects are as follows: 1) In case 1, 28 lumbar sympathetic blocks in both sides were performed. The patient did not complain of pain or tenderness and the limping improved. 2) In case 2, 7 lumbar sympathetic blocks were performed, but we could find only a slight improvement in the symptoms. 3) In case 3, 8 stellate ganglion blocks were carried out. The patient refused the treatment of RSDS because of the lack of rapid improvement. 4) In case 4, total 64 stellate ganglion blocks were carried out; the patient was permanently improved.

  • PDF

Application of Hydrogenated Amorphous Silicon(a-Si : H) Radiation Detectors in Nuclear Medicine

  • Lee, Hyoung-Koo;Mendez, Victor-Perez;Shinn, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.65-77
    • /
    • 1995
  • A new gamma camera using a-Si : H photodetectors has been designed for the imaging of heart and other small organs. In this new design the photomultiplier tubes and the position sensing circuitry are replaced by 2-D array of a-Si : H p-i-n pixel photode tectors and readout circuitry which are built on a substrate. Without the photomultiplier tubes this camera is light weight, hence can be made portable. To predict the characteristics and the performance of this new gamma camera we did Monte Carlo simulations. In the simulations 128${\times}$128 imaging array of various pixel sixes were used. $\^$99m/Tc(140keV)and $\^$201/Tl(70keV) were used as radiation sources. From the simulations we could obtain the resolution of the camera and ther overall system, and the blurring effects due to scattering in the phantom. Using the Wiener filter for image processing, restoration of the blurred image could be achieved. Simulation results of a-Si : H based gamma camera were compared with those of a conwentional gamma camera.

  • PDF