• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.032 seconds

Which Factors Related to the Renal Cortical Defects in Infants Under 3 Months of Age with Urinary Tract Infections?

  • An, Yu Kyung;Cho, Myung Hyun;Kim, Kyo Sun
    • Childhood Kidney Diseases
    • /
    • v.20 no.2
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: We used technetium-99m dimercaptosuccinic acid (DMSA) scintigraphy to identify factors predictive of renal cortical defects in infants <3 months of age with urinary tract infections (UTIs). Methods: We retrospectively reviewed data on infants <3 months of age with culture-proven UTIs treated at a single center from March 2010 to February 2016. Blood samples were obtained for laboratory evaluation prior to commencement of antibiotic therapy. The therapeutic delay time (TDT) and therapeutic response time (TRT) were recorded. All patients were divided into two groups depending on features of their DMSA scans. We compared the demographic, clinical, and laboratory characteristics of the two groups. Results: A total of 119 infants (94 males and 25 females; mean age, $56.9{\pm}21.3days$) were included. Cortical defects were evident in the DMSA scans of 47 cases (39.5%). In infants with such defects, the peak temperatures ($38.9{\pm}0.57^{\circ}C$ vs. $38.4{\pm}0.81^{\circ}C$, P=0.001), the absolute neutrophil counts ($8,920{\pm}4,460/mm$ vs. $7,290{\pm}4,090/mm$, P=0.043), and the C-reactive protein (CRP) levels ($6.49{\pm}4.33mg/dL$ vs. $3.21{\pm}2.81mg/dL$, P=0.001) were significantly higher than those in infants without cortical defects. The TDT was also longer in those with cortical defects (P=0.037). Conclusion: We found that a TDT ${\geq}8.5hr$ (odds ratio [OR] 5.81), a peak temperature ${\geq}38.3^{\circ}C$ (OR 6.19), and a CRP level ${\geq}4.96mg/dL$ (OR 7.26) predicted abnormal DMSA scan results in infants <3 months of age with UTIs.

The Preoperative Evaluation of the Carotid Artery in Head and Neck Surgery (두경부수술에서 경동맥 희생과 사전검사)

  • Kwon Tack-Kyun;Sung Myung-Whun;Kim Kwang-Hyun;Kim Jeong-Jun;Lee Chul-Hee;Min Yang-Gi
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.175-181
    • /
    • 1998
  • Objectives: The authors tried to analyze the results of carotid artery sacrifice with or without preoperative carotid evaluation. Materials and Methods: Thirteen patients undergone carotid sacrifice were evaluated. Carotid balloon occlusion test (BOT) and single-photon emission computed tomography (SPECT) with technetium-99m-labeled hexamethylpropyleneamineoxime ($^{99m}Tc-HMPAO$) were used for preoperative carotid evaluation. Results: The causes of carotid artery sacrifice consisted of the neck mass involving the carotid artery, spontaneous aneurysmal rupture, and traumatic pseudoaneurysm. Five patient had postoperative neurologic complications and two of them had permanent neurologic deficits. Conclusion: The authors stress that the preoperative evaluation in carotid artery sacrifice is imperable, and the BOT with SPECT can be used in selecting the method of treatment. But since these tests cannot predict the postoperative outcome perfectly, careful perioperative care of the patients should be exercised regardless of the results of the preoperative evaluation.

  • PDF

Early-Phase SPECT/CT for Diagnosing Osteomyelitis: A Retrospective Pilot Study

  • Soo Jin Lee;Kyoung Sook Won;Hyung Jin Choi;Yun Young Choi
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.604-611
    • /
    • 2021
  • Objective: The aim of this pilot study was to investigate the potential of early-phase single-photon emission computed tomography (SPECT)/computed tomography (CT) using technetium-99m methyl diphosphonate (99mTc-MDP) for diagnosing osteomyelitis (OM). Materials and Methods: Twenty-one patients with suspected OM were enrolled retrospectively. Three-phase bone scan (TPBS), early-phase SPECT/CT (immediately after blood pool planar imaging), and delayed-phase SPECT/CT (immediately after delayed planar imaging) were performed. The final diagnoses were established through surgery or clinical follow-up for over 6 months. We compared three diagnostic criteria based on (I) TPBS alone, (II) combined TPBS and delayed-phase SPECT/CT, and (III) early-phase SPECT/CT alone. Results: OM was diagnosed in 11 of 21 patients (nine surgically and two clinically). Of the 11 OM patients, criterion-I, criterion-II, and criterion-III were positive in six, seven, and 10 patients, respectively. Of the 10 non-OM patients, criterion-I, criterion-II, and criterion-III were negative in five, five, and seven patients, respectively. The sensitivity/specificity/accuracy of criterion-I, criterion-II, and criterion-III for diagnosing OM were 54.5%/50.0%/55.0%, 63.6%/50.0%/57.1%, and 90.9%/70.0%/87.5%, respectively. Conclusion: This pilot study demonstrated the potential of using the early-phase SPECT/CT to diagnose OM. Based on the results, prospective studies with a larger sample size should be conducted to confirm the efficacy of early-phase SPECT/CT.

The Evaluation of Clinical Usefulness on Application of Myocardial Extract in Quantitative Perfusion SPECT (QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가)

  • Yun, Jong-Jun;Lim, Yeong-Hyeon;Lee, Mu-Seok;Song, Hyeon-Seok;Jeong, Ji-Uk;Park, Se-Yun;Kim, Jae-Hwan;Kim, Jeong-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2011
  • Purpose: As to analytical method of data, the AutoQUANT software in which it is used quantitative rating of the myocardial perfusion SPECT are reported that there is a difference. Therefore the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made data of the same patient. The purpose of this study is to offer the comparative analysis of myocardial extract method in Quantitative Perfusion SPECT. Materials and methods: We analyzed the 51 patients who were examined by Tc-99m MIBI gated myocardial SPECT in nuclear medicine department of Pusan National University Hospital from June to December 2010(34 men, 17 women, mean age $66.5{\pm}9.9$). We acquired the extracted image in myocardial extract protocol. QPS program that uses the AutoQUANT software measured TID(Transient Ischemic Dilation), ESD(Extent of Stress Defect), SSS(Summed Stress Score). Then analyzed the results. Results: The correlation of appyling myocardial extract is TID(r=0.98), ESD(r=0.99), SSS(r=0.99). In the 95% confidence limit, there was no satistically significant difference(TID p=0.78, ESD p=0.31, SSS p=0.19). After blinding test with a physician for making a qualitative analysis, there was no difference. Conclusion: Quantitative indices in QPS program showed good correlation and the results showed no statistically signigicant difference. The variance between method was small. therefore, the functional parameters by each method can be used interchangeably. Also, we expect patient's satisfaction.

  • PDF

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.

New Synthesis of Sestamibi and Comparison of Stability of Its Formulation (Sestamibi의 신규합성과 제제화에 따른 안정성 비교)

  • Son, Mi-Won;Lim, Joong-In;Chang, Young-Soo;Jung, Mi-Young;Jeong, Lak-Shin;Kim, Soon-Hoe;Kim, Won-Bae;Jeong, Jae-Min
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.5
    • /
    • pp.334-341
    • /
    • 2001
  • Purpose: Ascorbic acid us known to act as an antioxidant. Therefore, it can be used in increasing the efficiency of radiochemical labeling of Technetium-99m setamibi by inhibition of oxidation of $Sn^{2+}$ at low concentration. We intended to estimate the efficiency of radiochemical labeling and the stability of the newly formed formulation when ascorbic acid was added to a commercial kit. Materials and Methods: Synthesis of sestamibi was performed according to Dong-A's patent procedure (No.10-2001-0012877). First, we undertook a study to evaluate the efficiency of radiochemical labeling of sestamibi containing ascorbic acid. The stability of the vials was assessed using either $7.5{\mu}g\;or\;75{\mu}g$ of ascorbic acid, added to commercial vials under the accelerated condition(Temp : $40^{\circ}C{\pm}2^{\circ}C$, Relative humidity : $75{\pm}5%$). Results: Sestamibi was synthesized in overall 35-40% yield over 5 steps from a commercially available methallyl chloride as a starling material. When ascorbic acid was added, the efficiency of radiochemical labeling was maintained compared to the vial with no ascorbic acid. The accelerated test showed that the addition of ascorbic acid inhibited the oxidation of $Sn^{2+}$ ion by antioxidation mechanism. Also, the efficiency of radiochemical labeling of this vial after 9 months was nearly the same as the starting point. Therefore, the storage period of the kit is likely to be extended. Taken together, it suggests that the addition of ascorbic acid as a stabilizer is desirable. Conclusion: To increase the stability of a sestamibi cold kit, it is desirable to add ascorbic acid as a stabilizer to the commercial formulation.

  • PDF

The Effect of Sympathectomy on Bone: -Evaluation with Quantitative Bone Scintigraphy- (흰쥐에서 교감신경절제술이 골에 미치는 영향 : -정량적 골스캔을 이용한 평가-)

  • Kim, Hak-Hee;Yang, Woo-Jin;Lee, Seong-Yong;Chung, Soo-Kyo;Park, Jang-Sang;Yim, Jung-Ik;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.85-88
    • /
    • 1994
  • 근래 골조직에 있어서 자율신경의 기능에 대하여 많은 연구가 이루어지고 있으며, 골내의 자율신경의 해부학적 분포는 많이 알려져 있다. 그러나 임상적으로 반사적 교감신경 이상이나 레이노드 현상등과 같은 교감신경의 기능이상증에서나, 버거씨병 등의 치료 목적으로 시행되고 있는 교감신경 절제술 후, 자율신경기능의 변화가 사지골의 혈류나 골대사에 미치는 영향에 대하여는 아직도 논란의 여지가 있다. 저자들은 교감신경절제술 후 시간 경과에 따른 골에 미치는 영향을 알아보기 위하여 흰쥐에서 골대사와 혈류상태를 비교적 충실히 반영하는 정량적 골스캔을 시행하였다. 체중 $300{\sim}400g$의 수컷 흰쥐 10마리에서 복강을 통한 편측 요추부 교감신경절제술을 시행하였고, 수술 전과 후 1일, 3일, 1주, 2주, 3주, 4주에 양측 하지에서 각각 골스캔을 시행하고 교감신경 절제측 하지와 정상 하지에 대칭적으로 관심구역을 정하여 양측의 골스캔상 섭취계수를 비교하였다. 측정부위는 각 하지의 대퇴골간, 경골간 및 중족골로 하였다. 교감신경 절제술을 시행한 하지에서는 골스캔 소견상 수술 후 1일 또는 3일부터 동위원소 집적이 유의하게 증가되었으며 원위부로 갈수록 더욱 증가되었다. 그러나 3주 이후에는 정상측 수준으로 환원되었다. 교감신경절제술 후 골스캔상 동위원소집적이 증가되는 것은 골자체의 혈류가 증가되기 때문이며 이차적으로 골의 흡수를 유발하여 골밀도가 감소하는 것으로 생각되는데 이러한 변화는 시술 후 1일 째부터 관찰되어 사지골이 교감신경 절제에 매우 민감하게 반응하는 것을 알 수 있었다.9m}Tc$-MAA를 이용한 간 동맥 혈류 검사는 간암에서 색전술의 효과를 정확히 평가할 수 있는 유용한 검사법으로 이용될 수 있으리라 생각한다. 활성화 과정을 알아볼 수 있었으며 위상영상히스토그램을 통하여 이를 정량화하여 심실내 전기적 활성의 비동시성 여부를 추적관찰 할 수 있는 비관혈적검사임을 확인하였다.며, 3. $^{99m}Tc$으로 표지된 avidin과 streptavidin은 먼저 간으로 흡수된 후 대사된 다음 신장으로 배설된다는 사실을 알았다.damole에 의한 부작용은 흉통, 두통, 복통 등의 순이었고 전예에서 호전되었으며 생명에 위험을 초래할 수 있는 정도의 심장마비나 심부정맥은 한 예에서도 없었다. 결론적으로 dipyridamole은 약물부하 심근 SPECT 검사에 안전하게 사용할 수 있는 약물로 사료된다. 미소핵 빈도수가 증가하는 경향을 보였으나, 각 군간에 통계학적으로 유의한 차이는 없었다(p>0.05). 결론 : 임상적으로 치료를 중단하게 되는 1000mCi/60 Kg(16.67 mCi/Kg)를 투여한 군에서도 생쥐 골수내 미소핵이 발현되지 않는 것으로 보아, 방사성옥소는 비교적 안심하고 치료에 사용할 수 있는 제제로 사료되었다.반드시 비례하지만은 않아서 시간경과에 따른 추후 검사가 필요하리라 생각된다. 또한 방광요관역류가 있는 환아에서 DMSA 섭취율로 신기능을 평가할 때, 특히 영유아에서 연령에 따른 고려가 있어야 할 것으로 보인다.었다. 4) $^{99m}Tc-DISIDA$ hepatobiliary scintigram 음성율을

  • PDF

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

The Parathyroid Gland: An Overall Review of the Hidden Organ for Radiologists (부갑상선: 부갑상선 영상에 익숙하지 않은 영상의학과 의사들을 위한 전반적인 검토)

  • Suho Kim;Jung Hee Shin;Soo Yeon Hahn;Haejung Kim;Myoung Kyoung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.327-344
    • /
    • 2024
  • Parathyroid glands are small endocrine glands that regulate calcium metabolism by producing parathyroid hormone (PTH). These are located at the back of the thyroid gland. Typically, four glands comprise the parathyroid glands, although their numbers may vary among individuals. Parathyroid diseases are related to parathyroid gland dysfunction and can be caused by problems with the parathyroid gland itself or abnormal serum calcium levels arising from renal disease. In recent years, as comprehensive health checkups have become more common, abnormal serum calcium levels are often found incidentally in blood tests, after which several additional tests, including a PTH test, ultrasonography (US), technetium-99m sestamibi parathyroid scan, single-photon-emission CT (SPECT)/CT, four-dimensional CT (4D-CT), and PET/CT, are performed for further evaluation. However, the parathyroid gland remains an organ less familiar to radiologists. Therefore, the normal anatomy, pathophysiology, imaging, and clinical findings of the parathyroid gland and its associated diseases are discussed here.