• Title/Summary/Keyword: ${131}^I$

Search Result 1,086, Processing Time 0.03 seconds

Changes of Silk Fibroin Molecular Weight by Plastein Reaction (Plastein反應에 의한 絹피브로인의 分子量變化)

  • 김동건;판부막;소사효
    • Journal of Sericultural and Entomological Science
    • /
    • v.40 no.2
    • /
    • pp.131-135
    • /
    • 1998
  • Changes of silk fibroin molecular weight was studied by enzymatic proteolysis and reverse reaction of enzymatic proteolysis (plastein reaction) using chromatography, X-ray diffraction and thermal analysis methods. When the treatment of enzymatic proteolysis with $\alpha$-chymotripsin to silk fibroin solution, a precipitate of Fcp fractions was formed. And, this was dissolved in LiBr aqueous solution, the precipitate of PIFcp fractions was obtained again. Fcp and PIFcp fractions showed silk IIand silk Itype structure, respectively. Fcp fractions was about 6,900 in molecular weight, PIFcp fractions obtained by plastein reaction on the precipitate of Fcp fractions increased molecular weight to abort 15,000. The molecular weight of Fcp fractions was increased by plastein reaction, but Fcp fractions almost transited to silk I type crystal. The structure of silk I type of PIFcp fractions was steady identified by X-ray diffraction and thermal analysis. As molecular weight of Fcp fractions was gradually low, PIFcp fractions was become to macromolecule little by little.

  • PDF

Effect of Ginsenoside on Basal and Nitro-L-Arginine Suppressed Nitric Oxide Production in Rat Kidney

  • Kim, Hye-Young;Han, Sang-Won
    • Biomolecules & Therapeutics
    • /
    • v.2 no.2
    • /
    • pp.131-135
    • /
    • 1994
  • The effect of ginsenoside (GS) from Panax ginseng on basal and nitro-L-arginine suppressed nitric oxide (NO) production was studied in rat kidney. NO production was determined by conversion to [$^{14C}$]=L-citrulline from [$^{14C}$]-L-arginine both in whole kidney and three renal segments; glomerulus, cortex excluding glomerulus (cortex-) and medulla. Nitro-L-arginine (total dose of 30 mg/kg/3 days, i.p.) significantly reduced NO production in whole kidney, which was prevented by GS pretreatment (30 mg/kg/3 days, i.p.). Relative high dose of GS (120 mg/kg/4 days, i.p..) selectively increased NO production in glomerulus and cortex-. Protein content, on wet weight basis, in cortex- and glomerular DNA content were significantly reduced by GS. Our results confirm the existence of constitutive nitric oxide synthase in kidney and it seems that target nephron segment for volume expansion due to GS'NO-mediated vasodilation and for NO production stimulated by GS is cortex including glomerulus.lus.

  • PDF

A Blockchain Application for Personal health information: Focusing on Private Block Scheme (개인 의료정보 보호를 위한 블록체인 적용 방안: 프라이빗 블록 스킴을 중심으로)

  • Kwon, HyukJun;Kim, Hyeob;Choi, Jaewon
    • Knowledge Management Research
    • /
    • v.19 no.4
    • /
    • pp.119-131
    • /
    • 2018
  • In this paper, I research the issue of information security for medical information system of each parties. The outflow of the Personal medical information can lead to problems of medical systems and disadvantage to an individual. In this paper, we research the information security based on a blockchain. In addition, I have analyzed blockchain. I suggest a medical information system framework that can help to keep the privacy of patients by using a blockchain network. Also, In this paper try to explain using private blockchain for medical system. Blockchain can keep the integrity and transparency of the medical records. This research, shows how can build the private blockchain for medical records and how to get the integrity of Data from Private Blockchain and Distuributed Ledger Technology.

Quantitative measures of thoroughness of FBD simulations for PLC-based digital I&C system

  • Lee, Dong-Ah;Kim, Eui-Sub;Yoo, Junbeom
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.131-141
    • /
    • 2021
  • Simulation is a widely used functional verification method for FBD programs of PLC-based digital I&C system in nuclear power plants. It is difficult, however, to estimate the thoroughness (i.e., effectiveness or quality) of a simulation in the absence of any clear measure for the estimation. This paper proposes two sets of structural coverage adequacy criteria for the FBD simulation, toggle coverage and modified condition/decision coverage, which can estimate the thoroughness of simulation scenarios for FBD programs, as recommended by international standards for functional safety. We developed two supporting tools to generate numerous simulation scenarios and to measure automatically the coverages of the scenarios. The results of our experiment on five FBD programs demonstrated that the measures and tools can help software engineers estimate the thoroughness and improve the simulation scenarios quantitatively.

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

A Study on $^{99m}Tc$-pertechnetate thyroid uptake in various thyroid diseases (각종(各種) 갑상선질환(甲狀腺疾患)의 $^{99m}Tc$-pertechnetate 갑상선섭취(甲狀腺攝取)에 관(關)한 연구(硏究))

  • Choi, Sung-Jae;Min, Hae-Sook;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.8 no.1_2
    • /
    • pp.29-37
    • /
    • 1974
  • The $^{99m}Tc$-pertechnetate thyroid uptake rates(20 min) were measured in 24 healthy normal subjects, 140 patients with nontoxic goiter and 98 patients with thyrotoxicosis who were treated at the Thyroid Clinic, Seoul National University Hospital, from August 1972 to August 1973. Diagnostic reliabilities and correlations between $^{99m}TcO_4$-thyroid uptake rate (20 min) and other thyroid function tests were evaluated. The observed results were as follows 1. The $^{99m}TcO_4$-thyroid uptake rates (20 min) in normal subjects, euthyroid group and hyperthyroid group were $4.1{\pm}0.9%,\;5.2{\pm}1.8%\;and\;29.7{\pm}10.6%$. There was a significant difference between the mean of the euthyroid group and the mean of the hyperthyroid group and so differentiation between them can be easy. 2. In the diagnosis of hyperthyroidism, the reliabilities of $^{99m}TcO_4$- thyroid uptake rate(20 min), $^{131}I$ thyroid uptake rate(24hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7\;were\;87.9{\sim}97.9%,\;81.2{\sim}94.4%,\;87.9{\sim}97.9%,\;90.5{\sim}99.3%\;and\;93.7{\sim}100%$. $^{99m}TcO_4$-thyroid uptake rate(20 min) is more accurate than $^{131}I$ thyroid uptake rate (24 hrs) in the diagnosis of hyperthyroidism. 3. $^{99m}TcO_4$-thyroid uptake rate (20 min) was well correlated with $^{131}I$ thyroid uptake rate (24 hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7$. Points in favor of $^{99m}Tc$ are that it gives a small radiation dose to the thyroid, that tests can be repeated at the short interval, the study can be completed at a single patient visit and it is particularly well suited for the assessment of thyroid function in patients being treated with an antithyroid drug.

  • PDF

Determination of Self-Disposal date by the Analysis of Radioactive Waste Contamination for 1131I Therapy Ward (131I 치료입원실 폐기물 방사능 오염도 분석 및 자체처분가능일자 산출)

  • Kim, Gi-sub;Jung, Haijo;Park, Min-seok;Jeon, Gjin-seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.3-6
    • /
    • 2013
  • Purpose: The treatment of thyroid cancer patients was continuously increased. According to the increment of thyroid cancer patients, the establishment of iodine therapy site was also increased in each hospital. This treatment involves the administration of radioactive iodine, which will be given in the form of a capsule. Therefore, protections and managements for radioactive source pollution and radiation exposure should be necessary for radiation safety. Among the many problems, the problem of disposing the radioactive wastes was occurred. In this study, The date for self-disposal for radioactive wastes, which were contaminated in clothes, bedclothes and trash, were calculated. Materials and Methods: The number of iodine therapy ward was 15 in Korea Institute of Radiological Medical and Sciences. Recently, 8 therapy wards were operated for iodine therapy patients and others were on standby for emergency treatment ward of any radiation accidents. Radioactive wastes, which were occurred in therapy ward, were clothes, bedclothes, bath cover for patients washing water and food and drink which was leftover by patients. Each sample was hold into the marinelli beaker (clothes, bedclothes, bath covers) and 90 ml beaker (food, drink, and washing water). The activities of collected samples were measured by HpGe MCA device (Multi Channel Analysis, CANBERRA, USA) Results: The storage period for the each kind of radioactive wastes was calculated by equation of storage periods based on the measurement outcomes. The average storage period was 60 days for the case of clothes, and the maximum storage period was 93 days for patient bottoms. The average storage period and the maximum storage period for the trash were 69 days and 97 days, respectively. The leftover foods and drinks had short storage period (the average storage period was 25 days and maximum storage period was 39 days), compared with other wastes. Conclusion: The proper storage period for disposing the radioactive waste (clothes, bedclothes and bath cover) was 100 days by the regulation on self-disposal of radioactive waste. In addition, the storage period for disposing the liquid radioactive waste was 120 days. The current regulation for radioactive waste self-disposing was not suitable for the circumstances of each radioactive therapy facility. Therefore, it was necessary to reduce the leftover food and drinks by adequate table setting for patients, and improve the process and regulation for disposing the short-half life radioactive wastes.

  • PDF

The Significance of Serum Thyroid Peroxidase as a New Tumor Marker in Papillary Thyroid Carcinoma after Thyroidectomy (유두상 갑상선암의 수술후 재발예측인자로서 혈청 Thyroid Peroxidase의 의의)

  • Chang Hang-Seok;Na Jae-Wung;Chung Woong-Youn;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.1
    • /
    • pp.46-51
    • /
    • 1999
  • Background: Total thyroidectomy and postoperative radiodiodine ablation therapy in differentiated thyroid carcinomas enhance the reliability of serum thyroglobulin(Tg) levels and radioiodine scan in detecting recurrence or distant metastasis. There have been, however, some limitations in using these methods under certain conditions. Recently, several reports have indicated that thyroid peroxidase(TPO) could be used as an alternative tumor marker. We aimed to estimate the significance of serum TPO levels in differentiated thyroid carcinoma. Materials and Methods: Forty-eight patients who had undergone total thyroidectomy due to papillary thyroid carcinomas and who had been followed-up for at least 3 years were classified into two groups: 27 patients without any evidence of recurrence in group 1; and 20 patients with recurrence or distant metastasis in group 2. All patients were examined by radioiodine scans. Serum Tg, TSH, antithyroglobulin antibody, and TPO were measured and the relationships were statistically analyzed. The sensitivity and specificity of $^{131}I$ scan, serum Tg, and serum TPO were evaluated. Results: Serum Tg levels were $3.81{\pm}5.16ng/mL$ in group 1 and $147.02{\pm}193.75ng/mL$ in group 2. Only 2 patients in group 1 showed Tg levels exceeding 10ng/mL. In contrast, 4 patients in group 2 were under 10ng/mL. Serum antithyroglobulin antibody and TSH levels showed no statistical difference between the two groups. In group 1, 16 patients showed negative serum TPO results, and 4 patients in group 2 showed negative results. There was no correlation among serum Tg levels, antithyroglobulin antibody titers, and serum TPO levels in each group. In group 2, 4 patients with negative serum Tg levels showed positive TPO results and positive whole body scans. Two cases with false negative $^{131}I$ scans showed positive serum TPO and Tg results. In 4 cases showing false negative serum TPO levels, serum Tg levels and $^{131}I$ scans were positive. Conclusion: Serum Tg levels, radioiodine scans, and serum TPO levels can be clinically used as complementary methods in the diagnosis of recurrent or metastatic thyroid carcinomas. Serum TPO levels may be helpful when other methods fail to detect recurrences or distant metastasis in highly suspected patients.

  • PDF

Assessment of Environmental Radioactivity Surveillance Results around Korean Nuclear Power Utilization Facilities in 2017

  • Kim, Cheol-Su;Lee, Sang-Kuk;Lee, Dong-Myung;Choi, Seok-Won
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.118-126
    • /
    • 2019
  • Background: Government conducts environmental radioactivity surveillance for verification purpose around nuclear facilities based on the Nuclear Safety Law and issues a surveillance report every year. This study aims to evaluate the short and the long-term fluctuation of radionuclides detected above MDC and their origins using concentration ratios between these radionuclides. Materials and Methods: Sample media for verification surveillance are air, rainwater, groundwater, soil, and milk for terrestrial samples, and seawater, marine sediment, fish, and seaweed for marine samples. Gamma-emitting radionuclides including $^{137}Cs$, $^{90}Sr$, Pu, $^3H$, and $^{14}C$ are evaluated in these samples. Results and Discussion: According to the result of the environmental radioactivity verification surveillance in the vicinity of nuclear power facilities in 2017, the anthropogenic radionuclides were not detected in most of the environmental samples except for the detection of a trace level of $^{137}Cs$, $^{90}Sr$, Pu, and $^{131}I$ in some samples. Radioactivity concentration ratios between the anthropogenic radionuclides ($^{137}Cs/^{90}Sr$, $^{137}Cs/^{239+240}Pu$, $^{90}Sr/^{239+240}Pu$) were similar to those reported in the environmental samples, which were affected by the global fallout of the past nuclear weapon test, and Pu atomic ratios ($^{240}Pu/^{239}Pu$) in the terrestrial sample and marine sample showed significant differences due to the different input pathway and the Pu source. Radioactive iodine ($^{131}I$) was detected at the range of < $5.6-190mBq{\cdot}kg-fresh^{-1}$ in the gulfweed and sea trumpet collected from the area of Kori and Wolsong intake and discharge. A high level of $^3H$ was observed in the air (Sangbong: $0.688{\pm}0.841Bq{\cdot}m^{-3}$) and the precipitation (Meteorology Post: $199{\pm}126Bq{\cdot}L^{-1}$) samples of the Wolsong nuclear power plant (NPP). $^3H$ concentration in the precipitation and pine needle samples showed typical variation pattern with the distance and the wind direction from the stack due to the gaseous release of $^3H$ in Wolsong NPP. Conclusion: Except for the detection of a trace level of $^{137}Cs$, $^{90}Sr$, Pu, and $^{131}I$ in some samples, anthropogenic radionuclides were below MDC in most of the environmental samples. Overall, no unusual radionuclides and abnormal concentration were detected in the 2017's surveillance result for verification. This research will be available in the assessment of environment around nuclear facilities in the event of radioactive material release.

Evaluation of Caregivers' Exposed Dose and Patients' External Dose Rate for Radioactive Iodine (I-131) Therapy Administration in Isolated Ward (방사성요오드(I-131) 격리병실 치료 관리를 위한 환자의 체외방사선량률과 상주 보호자의 피폭선량평가)

  • Kang, Seok-Jin;Lee, Doo-Hyeon;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.347-353
    • /
    • 2022
  • In this study, the radiation dose rate was measured by time and distance and evaluated whether radiation dose rate was suitable for domestic and international discharge criteria. In addition, the radiation dose emitted from the patient was measured with a glass dosimeter to evaluate the exposure dose if the caregiver stays in the isolated ward by placing a humanoid phantom instead of the caregiver at a distance of 1 m from the patient, on the second day of treatment. After 23 hours of isolation, the radiation dose rates at a distance of 1 m were 20.54 ± 6.21 µSv/h at 2.96 GBq administration and 27.94 ± 12.33 µSv/h at 3.70 GBq administration. The radiation dose rates at a distance of 1 m were 25.90 ± 2.21 µSv/h when 2.96 GBq was administered and 34.22 ± 10.06 µSv/h when 3.70 GBq was administered after 18 hours of isolation. However, if the isolation period is short may cause unnecessary radiation exposure to the third person. The reading of the attached dosimeter from the morning of the second day of treatment until removal was 0.01 to 0.95 mSv, which is a surface dose determined by the International Commission on Radiation Units and Measurements. And the depth dose was 0.01 to 0.99 mSv. On the second day of treatment, even if the patient caregivers stayed in the isolation ward, the exposure dose of the patient family did not exceed the effective dose limit of 5 mSv recommended by the ICRP and NCRP.