• Title/Summary/Keyword: ${\triangle}$-reduction

Search Result 36, Processing Time 0.019 seconds

△-CLOSURES OF IDEALS WITH RESPECT TO MODULES

  • Ansari-Toroghy, H.;Dorostkar, F.
    • Honam Mathematical Journal
    • /
    • v.30 no.1
    • /
    • pp.101-113
    • /
    • 2008
  • Let M be an arbitrary module over a commutative Noetherian ring R and let ${\triangle}$ be a multiplicatively closed set of non-zero ideals of R. In this paper, we will introduce the dual notion of ${\triangle}$-closure and ${\triangle}$-dependence of an ideal with respect to M and obtain some related results.

Biaxial creep property of ethylene tetrafluoroethylene (ETFE) foil

  • Li, Yintang;Wu, Minger
    • Structural Engineering and Mechanics
    • /
    • v.54 no.5
    • /
    • pp.973-986
    • /
    • 2015
  • Ethylene tetrafluoroethylene (ETFE) foil is a novel structural material which has being used in shell and spatial structures. This paper studies biaxial creep property of ETFE foil by creep tests and numerical simulation. Biaxial creep tests of cruciform specimens were performed using three stress ratios, 1:1, 2:1 and 1:2, which showed that creep coefficients in biaxial tension were much smaller than those in uniaxial one. Then, a reduction factor was introduced to take account of this biaxial effect, and relation between the reduction factor and stress ratio was established. Circular bubble creep test and triangle cushion creep test of ETFE foil were performed to verify the relation. Interpolation was adopted to consider creep stress and reduction factor was involved to take account of biaxial effect in numerical simulation. Simulation results of the bubble creep test embraced a good agreement with those measuring ones. In triangle cushion creep test, creep displacements from numerical simulation showed a good agreement with those from creep test at the center and lower foil measuring points.

Acoustic Resonance Reduction Technique in HID-lamps by the FM Driving Signal for the Inverter (인버터 구동신호의 주파수 변조에 의한 HID 램프의 음향 공명 감소 기법)

  • Park, Chong-Yun;Choe, Hyueon-Hui;Lim, Ki-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1981-1987
    • /
    • 2008
  • This paper proposed one of various acoustic resonance reduction technique for three kinds of ceramic lamps (CDM-150, HCI-150, CMH-150). To reduce the acoustic resonance in the HID lamps, the researched results showed that the frequency modulated signal with the triangle waveform is very effective in order to drive th LCC type half-bridge inverter for HID lamp. Experimental results proved that the acoustic resonance could be rejected, if the adequate switching frequency band is selected and the driving signal frequency is modulated with a triangle waveform.

Characteristics of Collected Sediments from Road Sweeping and Reduction in the Nonpoint Source Pollutants Loading (도로청소 수거퇴적물의 특성과 비점오염물질 저감효과)

  • Jeong, Kwon;Kang, Hee-Man;Ko, Seok-Oh
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • The stormwater runoff from road or expressway is known as one of important nonpoint pollution sources. To reduce the pollutants discharge from road or expressway, many best management practices(BMPs) have been applied and planned. Among the BMPs, road sweeping can be effective way to prevent pollutant washoff to environment. This study is performed to evaluate the characteristics of particles collected from the road by sweeping car. Size distribution and pollutant concentration of particles were analyzed. Based on the pollutant concentration and the specification of road such as length, width, and unit for pollutant generation, total amount of pollutant to be removed by road sweeping was estimated. Most of sediments collected by road sweeping was classified into sandy soil and fraction of fine grained soil was low. Although the concentrations of pollutants such as heavy metals in road sediments did not exceed the soil contamination criteria, washout of pollutants during sweeping work by spraying water might cause leaching of pollutants contained in sediments and thus resulted in low pollutant concentrations. Reduced amounts of pollutant by road sweeping showed 31.4% TSS reduction for ${\bigcirc}{\bigcirc}$ region and 7.7% TSS for ${\triangle}{\triangle}$ region. Other pollutants showed low reduction rate, because of their leaching by water spraying. Results from this study indicate that detailed and well-planned investigation for the road sweeping is necessary for the accurate estimation of pollutant reduction from road or expressway.

STRUCTURED CODEWORD SEARCH FOR VECTOR QUANTIZATION (백터양자화가의 구조적 코더 찾기)

  • 우홍체
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.467-470
    • /
    • 2000
  • Vector quantization (VQ) is widely used in many high-quality and high-rate data compression applications such as speech coding, audio coding, image coding and video coding. When the size of a VQ codebook is large, the computational complexity for the full codeword search method is a significant problem for many applications. A number of complexity reduction algorithms have been proposed and investigated using such properties of the codebook as the triangle inequality. This paper proposes a new structured VQ search algorithm that is based on a multi-stage structure for searching for the best codeword. Even using only two stages, a significant complexity reduction can be obtained without any loss of quality.

  • PDF

Analysis of the whole body shape of old-old aged males -focused on 70-85 aged males-

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.5
    • /
    • pp.81-91
    • /
    • 2019
  • In this study, 3D measurement data of 70 to 85 years old men were analyzed to investigate the body shape characteristics. and the type of the whole body of older men. Through this study, we aimed to provide basic data necessary for making good clothes for elderly men. We analyzed the body shape of elderly males using Korea 's 2015 elderly anthropometric data by SPSS Ver. 24.0. The body shape of older males was classified into four types: 'thin & long inverted triangle with thick legs', 'thick & short inverted triangle with bird legs', 'thick & long triangle with thick legs', 'thick & short triangle with thick legs'. As the age increases, the shoulders are sagging, the progressive reduction of the spine leads to a decrease in height, and the backbone refraction causes a decrease in the anterior center length and an increase in the back length. In addition, as the age increases, the chest circumference decreases and the abdomen and waist circumference increase. Considering these physical changes, it is necessary to set the length of the garment to 2-3cm shorter in the case of the aged layer. Waist and abdomen area are increased, it is considered that it will be necessary to add more margin of 2cm than general silver clothing when setting the margin amount. When setting the length of the upper body, it is considered that the front center length should be reduced and the back length should be increased to keep the bottom level. In this study, only the elderly males aged 70-85 years were included in the analysis of the whole body type. It is significant that the studies so far have been extended to those older than 70 years. Future research will need to be applied to the development of silver clothing through comparison of older men 's body shape in their 60s and 70s.

Monochorionic Triamniotic Triplet Pregnancy Following Assisted Reproductive Technology and Radiofrequency Ablation for Selective Reduction

  • Lee, Jeong-Heon;Oh, Su-Hyun;Hong, Ah-Reum;Jeong, Young-Ju;Cho, Sung-Nam;Cho, Dong-Hyu
    • Perinatology
    • /
    • v.29 no.4
    • /
    • pp.180-184
    • /
    • 2018
  • In assisted reproductive techniques, monozygotic twinning is not influenced by the trial of reducing the number of embryos transferred. We present extremely rare case of monochorionic triamniotic triplet pregnancy following in vitro fertilization and two-embryo transfer. During the first trimester, the crucial ultrasound findings of monochorionic triamniotic triplet pregnancy are three distinct amniotic sacs forming a triangle or ipsilon zone within a single chorionic cavity. After prudential counseling about the potential risk of a monochorionic triamniotic triplet pregnancy with the patient, selective reduction of two fetuses via radiofrequency ablation was performed. We report a case of selective reduction for monochorionic triamniotic triplet pregnancy using radiofrequency ablation at 12 weeks' gestation and obstetric progression after radiofrequency ablation was uneventful until 20 weeks' gestation.

SIMULINK Modeling for Induction Mortor Drive System using SV_PWM (SV_PWM을 이용한 유도전동기구동시스템의 SIMULINK 모델링)

  • Lee, Hak-Ju;Kim, Min-Tae;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2143-2145
    • /
    • 1997
  • SV_PWM inverter for Induction motor drive system was designed at SIMULINK environment in MATLAB. This paper was performed the analysis of output current harmonics using DSP blockset. It was roved in this paper that SV_PWM method has been ore effective than triangle comparison PWM method on harmonic reduction at steady state.

  • PDF

Noise Reduction Technique by Three-Points Ensemble Averaging in Uroflowmetry (삼점 신호 평균기법에 의한 요속신호의 잡음 축소 기법)

  • Choi, Seong-Su;Lee, In-Kwang;Lee, Sang-Bong;Park, Jun-Oh;Lee, Su-Ok;Cha, Eun-Jong;Kim, Kyung-Ah
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1638-1643
    • /
    • 2009
  • Uroflowmetry is a convenient clinical test to screen the benign prostatic hyperplasia(BPH) common in the aged men. A load cell is located beneath the urine container to measure the weight of urine. However, it is sensitive to the impact applied on the bottom of the container by the urine stream, which could be a noise source lowering the reliability of the system. With this aim, our study proposed a noise reduction technique by computing ensemble average of the weighted signals that were acquired from three-load cells forming a regular triangle beneath the urine container. Simulated urination experiment was performed with three different collection methods, all of which demonstrated significant noise reduction by ensemble averaging. Furthermore, the best results can be obtained without any special urine collection devices. Thus, our novel method can be usefully applied to uroflowmetry for enhancing measurement in terms of accuracy and reliability.

Analysis of ELF Magnetic Field Reduction Factor of Electric Power Transmission Line (송전 선로 극저주파 자기장 저감지수(FRF) 특성 해석)

  • Myung, Sung-Ho;Cho, Yeon-Gyu;Lee, Dong-Il;Lim, Yun-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1132-1142
    • /
    • 2006
  • This paper examined electric power transmission line models of reducing ELF(Extremely Low Frequency) magnetic field and analyzed the effects about models. In this research, FRF(Field Reduction Factor) of various models reducing magnetic field were analyzed compared to the horizontal 154 kV transmission line. As a result, the reduction ratio of magnetic field was almost proportioned to the compaction of phase-to-phase distance, and in case of diamond model and transposed model, magnetic field was able to be reduced nearly 50 %. It was analyzed that the magnetic field reduction ratio of triangle model was about 33 % and the magnetic field reduction ratio of split model was able to be reduced to 50 %. Especially, the magnetic field reduction ratio of multi split model could be reduced to 80 %.