• 제목/요약/키워드: ${\mu}-TAS$

검색결과 37건 처리시간 0.022초

Oxytocin Ameliorates Remote Liver Injury Induced by Renal Ischemia-Reperfusion in Rats

  • Hekimoglu, Askin Tas;Toprak, Gulten;Akkoc, Hasan;Evliyaoglu, Osman;Ozekinci, Selver;Kelle, Ilker
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제17권2호
    • /
    • pp.169-173
    • /
    • 2013
  • Renal ischemia-reperfusion (IR) causes remote liver damage. Oxytocin has anti-inflammatory and antioxidant effects. The main purpose of this study was to evaluate the protective function of oxytocin (OT) in remote liver damage triggered by renal IR in rats. Twenty four rats were randomly divided into four different groups, each containing 8 rats. The groups were as follows: (1) Sham operated group; (2) Sham operated+OT group (3) Renal IR group; (4) Renal IR+OT group. OT ($500{\mu}g/kg$) was administered subcutaneously 12 and 24 hours before and immediately after ischemia. At the end of experimental procedure, the rats were sacrificed, and liver specimens were taken for histological assessment or determination of malondialdehyde (MDA), total oxidant status (TOS), total antioxidant status (TAS), paraoxonase (PON-1) activity and nitric oxide (NO). The results showed that renal IR injury constituted a notable elevation in MDA, TOS, Oxidative stress index (OSI) and significantly decreased TAS, PON-1 actvity and NO in liver tissue (p<0.05). Additionally renal IR provoked significant augmentation in hepatic microscopic damage scores. However, alterations in these biochemical and histopathological indices due to IR injury were attenuated by OT treatment (p<0.05). These findings show that OT ameliorates remote liver damage triggered by renal ischemia-reperfusion and this preservation involves suppression of inflammation and regulation of oxidant-antioxidant status.

마이크로믹서에의 응용을 위한 batch type 초음파믹서의 혼합 상태 가시화 (Visualization for the mixing state of a batch-type ultrasonic mixer for its application to the microdevice)

  • 허필우;윤의수;고광식
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.47-51
    • /
    • 2005
  • An active ${\mu}$-mixer is important in Bio-MEMS and ${\mu}$-TAS. The mixing state depends on some kinds of factors including the intensity of ultrasonic radiation. We have visualized the mixing state of the mixing chamber with radiation time and presented the influence of the driving voltage in this research. It will be possible to compare the performances of the ultrasonic radiation parts used in the active ${\mu}$-mixer using this method.

Synthesis and In Vitro Cytotoxicity of 1,3-Dioxoindan-2-Carboxylic Acid Arylamides

  • Jung, Jae-Kyung;Ryu, Jin-Hyeong;Yang, Sung-Il;Cho, Jung-Sook;Lee , Hee-Soon
    • Archives of Pharmacal Research
    • /
    • 제27권10호
    • /
    • pp.997-1000
    • /
    • 2004
  • A series of 1,3-dioxoindan-2-carboxylic acid arylamides were synthesized and evaluated for in vitro cytotoxicity against four human cancer cell lines (HOP62, SK-OV-3, MD-MB-468 and T- 47D). The most active was compound 3e (1.2 ${\mu}M$ against SK-OV-3 cell line) bearing a 4- methyl substituent.

3D 프린터를 이용한 마이크로 리액터 가공에 관한 연구 (Fabrication of Micro-reactor by 3D Printing Machine)

  • 최해운;윤성철;마재권;방대욱
    • 한국생산제조학회지
    • /
    • 제23권3호
    • /
    • pp.218-222
    • /
    • 2014
  • A 3D printer was used to fabricate a micro-TAS system for biomedical applications. A polymeric medical device fabrication based on a 3D printer can be performed at atmospheric conditions. A CAD- and CAM-based system is a flexible method to design medical components, and a 3D printer is a suitable device to perform this task. In this research, a 100-micron-wide fluidic channel was fabricated with a high-aspect ratio. A cross-sectional SEM image confirmed its possible usage in a micro-reactor using 3D printers. CNC-machined samples were compared to 3D printer-fabricated samples, and the advantages and disadvantages were discussed. Based on the SEM images, the surface roughness of the 3D printed reactor was not affected by wet or dry conditions due to its manufacturing principle. An aspect ratio of 5 to 1 was achievable with 100-${\mu}$ m-wide fluid channels. No melting was found, and the shape of channels was straight enough to be used for micro reactors.

절연층에 따른 액적의 전기습윤 특성 분석 (Characteristic Analysis of Electrowetting on Dielectric Layer)

  • 최진호;김규만
    • 한국기계가공학회지
    • /
    • 제18권8호
    • /
    • pp.38-43
    • /
    • 2019
  • Electrowetting on dielectric (EWOD) is a unique method of shape control of small-volume droplets in microfluidic biochips that relies on modification of surface wetting characteristics using electrical methods. In this study, the droplet shape control on various dielectric surfaces by the EWOD and the effect of droplets on the contact angle as well as the shape were investigated. The droplet used in the experiment was on a sample substrate with $5{\mu}l$ of de-ionized water (DIW) using a micropipette, and wettability was measured with a contact angle meter. This study is expected to be helpful for the development of various micro-total-analysis-systems (${\mu}TAS$) and microfluidic systems with MEMS technology.

실리콘 v-groove를 이용한 광섬유-광검출기 어레이 모듈 제작 (Fabrication of the Optical Fiber-Photodiode Array Module Using Si v-groove)

  • 정종민;지윤규;박찬용;유지범;박경현;김홍만
    • 전자공학회논문지A
    • /
    • 제31A권6호
    • /
    • pp.88-97
    • /
    • 1994
  • We describe the design, fabrication, and performance of the optical fiber-photodiode 1$\times$12 arry module using mesa-type InS10.53T GaS10.47TAS/INP 1$\times$12 PIN photodiode array. We fabricated the PIN PD array for high-speed optical fiber parallel data link optimizing quantum efficiency, operating speed sensitivity from the PIN-FET structure, and electrical AC crosstalk. For each element of the array, the diameter of the photodetective area is 80 $\mu$m, the diameter of the p-metal pad is 90 $\mu$m, and the photodiode seperation is 250 $\mu$m to use Si v-groove. Ground conductor line is placed around diodes and p-metal pads are formed in zigzag to reduce Ac capacitance coupling between array elements. The dark current (IS1dT) is I nA and the capacitance(CS1pDT) is 0.9 pF at -5 V. No signifcant variations of IS1dT and CPD from element to element in the array were observed. We calulated the coupling efficiency for 10/125 SMF and 50/125 GI MMF, and measured the responsivity of the PD array at the wavelength is 1.55 $\mu$ m. Responsivities are 0.93 A/W for SMF and 0.96 A/W for MMF. The optical fiber-PD array module is useful in numerous high speed digital and analog photonic system applications.

  • PDF

열공압 방식으로 구동되는 매세 유체 제어 시스템의 제작 및 특성 (Fabrications and Characteristics of Microfluidic Systems Actuated by Thermopneumatic Method)

  • 유종철;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권2호
    • /
    • pp.88-92
    • /
    • 2006
  • We present a microfluidic system with microvalves and a micropump that are easily integrated on the same substrate using the same fabrication process. The fabricated microfluidic system is suitable for use as a disposable device and its characteristics are optimized for use as a micro chemical analysis system (micro-TAS) and lab-on-a-chip. The system is realized by means of a polydimethylsiloxane (PDMS)-glass chip and an indium tin oxide (ITO) heater. We demonstrate the integration of the micropump and microvalves using a new thermopneumatic-actuated PDMS-based microfluidic system. A maximum pumping rate of about 730 nl/min is observed at. a duty ratio of 1 $\%$ and a frequency of 2 Hz with a fixed power of 500 mW. The measured power at flow cut-off is 500 mW for the microvalve whose channel width, depth and membrane thickness were 400 $\mu$m, 110 $\mu$m, and 320 $\mu$m, respectively.

냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정 (Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement)

  • 류지명;홍광표;박승일;최영현;이기홍
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.21-29
    • /
    • 2014
  • 삼축분광장치는 물질을 이루고 있는 자성 원소들의 거동, 즉 스핀 동역학을 측정하는데 적합한 장치로, 연구용 원자로 '하나로'에는 국내 유일의 냉중성자 삼축분광장치가 최근 설치되었다. 삼축분광장치는 중성자 빔을 제어하는 중성자광학 부품과 중성자 빔으로 인해 발생하는 방사선에 대한 차폐체로 이루어지며 이러한 부품은 수십 톤 중량의 기계구조물을 이룬다. 방사선 차폐는 중성자 빔 경로 이외의 방향으로 진행하는 중성자와 감마선을 효과적으로 막아 신호대 잡음비를 향상시키는 역할을 하며 구조물 내부의 방사화된 부품으로부터 발생하는 감마선을 차폐하여 장치 이용자의 피폭선량을 최소화한다. 그런데 설치된 냉중성자 삼축분광장치의 차폐체 중 전면부의 고하중으로 인해 장치 운영상 여러 가지 문제점이 발생, 전면 세그먼트 차폐체의 하중을 줄이는 구조개선이 불가피하였다. 이에 MCNPX 모의계산을 통해 냉중성자 삼축분광장치의 차폐체 최적화에 필요한 개선방향을 검토하였다. 상부 차폐체의 폴리에틸렌과 납의 추가 설치를 통해 전면 블록 차폐체 하중을 줄일 수 있는 최적 길이를 확인하였다. 그 결과, 전면 블록 차폐체의 높이 20%가 제거된 경우, 구조변경 전 대비 차폐체 상부에서 70% 수준의 감마선속이 나타남을 확인하였다. 하지만 높이를 줄일수록 전면 블록 차폐체의 하중을 줄일 수 있기 때문에, 차폐블록을 추가 제거하고 이에 대한 차폐능을 보상해 줄 방안으로 상부 납 차폐체의 위치 변화에 따른 중성자속과 감마선속을 예측해 보았다. 전면 블록 차폐체 높이의 35% 제거하고 상부 납 차폐체를 최하단부에서 10 cm에 설치한 경우, 전면 블록 차폐체 상부에서 감마선속이 각각 25%, 18% 증가하였다. 증가한 감마선속의 영향을 파악하기 위해 MCNPX 모의계산을 통해 공간의 감마선속 분포를 가시화하였다. 증가한 감마선속은 상부로 향하는 방향성을 띄며 이동하면서 소멸하여 검출기에 이르기 전에 낮아져 검출기와 실험자의 위치에 영향을 끼칠 수 없다고 판단하였다. 그래서 중성자속 및 감마선속과 고하중 문제를 동시에 해결할 수 있는 최적화 조건으로 차폐체 높이가 35% 제거되고 상부 납 차폐체가 10 cm 위치에 있는 경우를 선정하였다. 이 결과를 바탕으로 구조개선 작업을 실시하였으며 열형광선량계를 이용하여 콘크리트 차폐블록 외부에서 중성자와 감마선량을 측정하였다. 측정된 중성자 선량은 0.21 ${\mu}Svhr^{-1}$, 감마선량은 3.69 ${\mu}Svhr^{-1}$로 설계기준을 만족하였으며 피폭으로부터 실험자의 안전성을 확인하였다.

성인여성의 체지방률에 따른 영양소섭취, 렙틴, 아디포넥틴, 코티졸 및 인슐린농도 (Nutrient Intake, the Concentrations of Leptin, Adiponectin, Cotisol & Insulin by the Body Fat Content of Women)

  • 이순례;배현숙
    • 대한지역사회영양학회지
    • /
    • 제17권6호
    • /
    • pp.714-723
    • /
    • 2012
  • The aim of this study was to compare nutrient intakes, serum hormones (leptin, adiponectin, insulin), salivary cortisol and ${\alpha}$-amylase of middle-aged women by the percentage of body fat (% fat). Subjects were assigned to 3 groups by body fat (%) group I (27.5%), group II (32.5%), group III (37.7%). WHR of group II (0.97) was significantly higher than of group I, III (0.95) (p < 0.05). Nutrient intakes were not different among 3 groups. Serum leptin levels of group III ($16.53{\mu}g/ml$) were higher than in group I ($10.07{\mu}g/ml$), group II ($12.24{\mu}g/ml$) (p < 0.05). Salivary cortisol levels of group II ($0.39{\mu}g/dl$) were higher than in group I ($0.17{\mu}g/dl$) and group III ($0.15{\mu}g/dl$) (p < 0.05). Adiponectin concentrations were negatively correlated with TAS (r = -0.29) and positively correlated with HDL cholesterol (r = 0.27). Insulin levels were negatively correlated with total cholesterol (r = -0.33), Zn intake (r = -0.31) and positively correlated with WHR (r = 0.31). The overall anthropometric indices showed positive relations with leptin levels. Salivary cortisol levels were positively corelated with WHR (r = 0.28), total cholesterol (r = 0.31), MDA (r = 0.29) and intakes of SFA (r = 0.35) and MUFA (r = 0.3). Salivary amylase levels were positively correlated with overall nutrient intakes (energy, CHO, fat, cholesterol. Fe, SFA, MUFA, Zn, Na, vitamin $B_2$, r = 0.24-0.5) and was negatively correlated with HDL cholesterol (r = -0.34). These results suggested that 1) WHR would be a helpful index in the assessment of metabolic risk diseases. 2) Understanding of individual stress exposure should be considered in developing strategies for prevention and treatment of obesity.

다양한 동작신호의 사용에 따른 연동형 마이크로 펌프의 성능 향상 (Performance Improvement of Peristaltic Micropump Using Various Actuating Signal)

  • 홍표환;정동건;표대승;이종현;조찬섭;김봉환
    • 센서학회지
    • /
    • 제22권6호
    • /
    • pp.428-432
    • /
    • 2013
  • This paper described the development of electrostatically driven peristaltic micropump. The proposed micropump consists of a flexible membrane and a single chamber which electrodes are inserted. The single chamber is divided into smaller cells by the electrodes. The fabricated micropump was operated with four electrodes in the membrane and a various phase sequencing actuation. We studied the changes in the flow rate corresponding to the actuating signal applied to the micropump under the zero hydraulic pressure difference between lnlet port and outlet port. The pump was operated from 60 to 130 V. Whereas the maximum flow rate in basic actuating signal is about 83 ${\mu}1/min$ at 15 Hz, the maximum flow rate in optimized actuating signal is about 114 ${\mu}l/min$ at 10 Hz.