• Title/Summary/Keyword: ${\gamma}'$ 상

Search Result 481, Processing Time 0.035 seconds

Technical Details Imaging Axillary Lymph Nodes in Breast-Specific Gamma Imaging (유방특이감마영상검사에서 액와부 영상 획득 방법에 대한 연구)

  • Jang, Ji Yeon;Jung, Eun Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.115-119
    • /
    • 2012
  • Purpose : The initial Breast-Specific Gamma Imaging (BSGI) protocol included bilateral breast imaging with 2 views of each breast-craniocaudal (CC) and mediolateral oblique (MLO). Furthermore, Axillary lymph nodes view can be acquired easily. The most meaningful prognosis factor for prediction of breast cancer is whether or not the breast cancer has metastasized to the lymph nodes. However, axillary view doesn't conduct in clinical. This article collates a diverse data of BSGI and describes technical details to acquire optimal imaging. Materials and Methods : A retrospective review was performed on 343 patients who had undergone BSGI between May 2011 and March 2012. Patients who had undergone BSGI received intravenous injection of 740 MBq (20 mCi) $^{99m}Tc$-sestamibi. Results : The following contents are the technical details for optimal axillary imaging. $^{99m}Tc$-sestamibi should be administered using an indwelling venous catheter or scalp needle followed by 10 cc of saline to flush to reduce extravasation and vascular trapping. After administration, patients raise their arm over their head and exercise with stress ball for 1 full minute. A lead shield attached to the gamma camera is removed and patients axilla is placed as close as possible to the camera at a $90^{\circ}$ angle. A lead apron is placed across the shoulder to reduce background from other organs. Acquisition time is enough for 120 sec~180 sec. Conclusion : If patients undergo bilateral axillary imaging as a standard with CC, MLO views, it could improve cancer treatment. Result of this study could maximize efficiency axillary imaging of breast cancer patients.

  • PDF

The Catalytic Reduction of Sulfur Dioxide to Elemental Sulfur over Supported Cobalt Catalysts (담지 코발트 촉매를 이용한 SO2의 원소황으로의 환원반응 특성)

  • Park, Joon Hyo;Han, Jong Dae
    • Applied Chemistry for Engineering
    • /
    • v.10 no.8
    • /
    • pp.1129-1135
    • /
    • 1999
  • The reduction of $SO_2$ by CO over supported cobalt catalysts was investigated within the temperature range of $350{\sim}550^{\circ}C$, initial $SO_2$ concentration of 1000~10000 ppm, $CO/SO_2$ molar ratio of 1.0~3.0 and space velocity of $5000{\sim}15000h^{-1}$. Several types of supports such as ${\gamma}-Al_2O_3$, $TiO_2$ were tested. The $SO_2$ conversion and selectivity to elemental sulfur were investigated using a differential fixed bed reactor at atmospheric pressure. The catalyst prepared by wet impregration of 5 wt % cobalt on ${\gamma}-Al_2O_3$ showed $SO_2$ conversion higher than 90% and COS yield lower than 6% at temperature above $400^{\circ}C$. The optimum $CO/SO_2$ molar ratio was investigated as 2.0. At higher $CO/SO_2$ molar ratio, the $SO_2$ conversion became higher but the main product was COS. The effect of $SO_2$ concentration and space velocity over $SO_2$ conversion and COS yield was not appreciable in the experimental range. The activated cobalt phase was detected as $CoS_2$ and the $CoS_2$ phase unchanged even after reaction.

  • PDF

A Study of Electrical Anisotropy of n-type a-plane GaN films grown on $\gamma$-plane Sapphire Substrates ($\gamma$-plane 사파이어 기판 위에 성장한 무분극 ${alpha}$-plane GaN 층의 전기적 비등방성 연구)

  • Kim, Jae-Bum;Kim, Dong-Ho;Hwang, Sung-Min;Kim, Tae-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.1-6
    • /
    • 2010
  • We report on the electrical properties of Ti/Al/Ni/Au (20 nm/ 150 nm/ 30 nm/ 100 nm) Ohmic contacts and the anisotropic conductivity of n-type ${\alpha}$-plane ([11-20]) GaN grown on $\gamma$-plane ([1-102]) sapphire substrates. The Ti/Al/Ni/Au Ohmic contacts and their sheet resistances are characterized by using the transfer length method (TLM) as a function of azimuthal angles. It is found that the specific contact resistance does not depend on the axis orientation and there are significant electrical anisotropy in ${\alpha}$-plane GaN films on $\gamma$-plane sapphire substrates, and the sheet resistance varies with azimuthal angles. The sheet resistance values in the direction parallel to m-axis [1-100] are 25% ~ 75% lower than those parallel to c-axis [0001] directions. Thus, Basal stacking faults (BSFs) are offered as a feasible source of the anisotropic mobility in defected m-axis direction because the band-edge discontinuities owing to the differential band gap structure.

Direct Conversion of L-Selenomethionine into Methylselenol by Human Cystathionine ${\gamma}$-Lyase (인간 Cystathionine ${\gamma}$-Lyase에 의한 Selenomethionine의 Methylselenol로의 직접분해)

  • Cho, Hyun-Nam;Jhee, Kwang-Hwan
    • Microbiology and Biotechnology Letters
    • /
    • v.42 no.1
    • /
    • pp.11-17
    • /
    • 2014
  • Selenium is an essential trace element for mammals, but it is very toxic. Therefore, the control of selenium concentrations should be precisely and effectively monitored. Selenium is naturally obtained through foods and seleno-L-methionine (LSeMet) is a major form of selenium. It has been reported that L-SeMet is only converted into Se-adenosyl-L-SeMet. However, a recent study suggested that L-SeMet was directly metabolized into methylselenol ($CH_3SeH$) in mouse liver extract by the reaction of cystathionine ${\gamma}$-lyase (CGL). The canonical reaction of CGL was known to catalyze the cleavage of L-cystathionine to L-cysteine, ${\alpha}$-ketobutyrate and $NH_3$. In the present study, we found that L-SeMet could be directly converted to $CH_3SeH$ using purified homogenous human CGL instead of mouse liver cytosol. Authentic $CH_3SeH$ was prepared by reduction of dimethyldiselenide with sodium tetrahydroborate. The gaseous product of the enzymatic reaction with L-SeMet was analyzed by GC/MS spectrometry. The GC/MS data was identical to that of authentic dinitrophenyl selenoether. We also analyzed the kinetic parameters for the formation of $CH_3SeH$ from L-SeMet by human and mouse CGL. These results suggest that human CGL is a critical enzyme which is responsible for L-SeMet metabolism.

Comparison of tuberculin skin test with Interferon-γ assay for the diagnosis of bovine tuberculosis in Korean cattle (국내 우군에서 소 결핵 진단을 위한 피내검사법과 Interferon-γ 생성 검사의 비교)

  • Shin, Seung Won;Shin, Min Kyoung;Cha, Seung Bin;Woo, Jong Tae;Lee, Sung Mo;Ku, Bok Kyung;Cho, Yun Sang;Jung, Suk Chan;Yoo, Han Sang
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.2
    • /
    • pp.117-122
    • /
    • 2011
  • Bovine tuberculosis (bTB), caused primarily by Mycobacterium bovis, continues to exert an economic loss, even in countries with active control measures, and is one of zoonotic diseases enable to be transmitted to human. The control and eradication of bTB are mainly based on a test and slaughter policy and/or abattoir surveillance. Various factors including limitation of diagnostic tests have been considered as major constraints to eradication. Single intradermal test (SIT) is the official diagnostic test. New diagnostic methods are needed to be developed, because of limitations of the test. In the present study SIT was compared with single intradermal comparative cervical test (SICCT) and interferon (IFN)-${\gamma}$ assay. There was very low correlation between SIT and SICCT. However, high correlation was shown between SIT and IFN-${\gamma}$ assay while no correlation was observed between SICCT and IFN-${\gamma}$ assay. Therefore, our results suggest the possibility of replacement of SIT with IFN-${\gamma}$ assay for the diagnosis of bovine tuberculosis.

Quality Properties of Sausage Prepared with Gamma-Irradiated Natural Casing (감마선조사 천연케이싱의 사용이 소시지의 제조적성에 미치는 영향)

  • 조철훈;이주운;육홍선;김동호;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.1
    • /
    • pp.75-79
    • /
    • 2001
  • Quality changes in sausage stuffed into irradiated natural pork and lamb intestine were studied. Total aerobic bacteria of the sausage prepared with irradiated natural pork and lamb casing were significantly lower than those of nonirradiated casing and the $D_{10}$ value of those sausages were 1.71 and 1.58 kGy, respectively. The sausages in pork intestine vacuum-packaged and stored in a $4^{\circ}C$ refrigerator showed negligible change in the 2-thiobarbituric acid reactive substances (TBARS) value during storage except for 10-day when the TBARS value was higher than other storage days. Total working force for shear value of the sausages were lower with both irradiated casings but sensory evaluation showed no difference between treatments. As a results, the gamma irradiation was effective for sanitizing the natural pork and lamb casings, thereby preparing high quality sausages.

  • PDF

Steel Plate Thickness Gauge by means of Gamma-Ray Backscattering (감마선 빽스켓터링을 이용한 철판 두께 측정에 관하여)

  • 김덕진;김동훈
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.1
    • /
    • pp.18-23
    • /
    • 1966
  • An experimental study of a steel plate thickness gauge by means of the measurements of backscatered gamma-rays has been carried out. The difference between this and other methods is that this method does not include any shilding matterials in the detecting probe, because the primary radiations and the backscattered radiations are detected simultaneously by an NaI (TI) scintillating crystal, and the activity of the Co-60 source used is low enough. In this thickness gauge, the thickness of the steel plates can be read directly on the counting ratemeter scale. The optimum conditions in the source-to-detector distance, window width of the analyzer, energy and strength of the gamma-ray source were found experimentally. The results have shown that the accuracy of the gauge was about $\pm$3% in the range of 3 to 8mm thickness. This gauge can be used to detect the pits or corrosions on the inner walls of the steel pipes.

  • PDF

Effects of Nitrogen Contents on the Nitriding Characteristics of the Micro-Pulse Plasma and Post Oxidation Treated SCM440 Steel (SCM440강의 마이크로 펄스 플라즈마 질화 및 후산화처리시 질소농도에 따른 특성변화)

  • Lee, S.K.;Chung, I.S.;Lee, J.S.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.2
    • /
    • pp.117-128
    • /
    • 1999
  • This study was carried out to investigate the surface characteristics of SCM440 steel nitrided with various nitrogen contents for 7 hours at $520^{\circ}C$ by using micro-pulse plasma nitriding apparatus of hot wall type. The effects of oxidation treatment was also investigated on plasma nitrided in 30% nitrogen and post oxidized SCM440 steel at $500^{\circ}C$ in $H_2O$ atmosphere. The ${\gamma}^{\prime}-Fe_4N$ and ${\varepsilon}-Fe_{2-3}N$ phases were detected in compound layer of the nitrided steel. As the content of nitrogen in plasma gas increased with 30, 50, 70% on the micro-pulse plasma nitriding for SCM440 steel, the thickness of compound, diffusion layer and the surface hardness were increased. From the wear test results, the best wear resistance was appeared in the condition of ductile ${\gamma}^{\prime}-Fe_4N$ phase formed specimen at 30% nitrogen, whereas that of the treated with 50% and 70% nitrogen decreased owing to the exfoliation of brittle ${\varepsilon}-Fe_{2-3}N$ phase in the compound layer. On the nitrided and subsequently oxidized SCM440 steel, the surface layer consisted of $Fe_3O_4$, ${\gamma}^{\prime}-Fe_4N$, and ${\varepsilon}-Fe_{2-3}N$ phases. In these treatments, the dissolution of nitrides affect hardness and hardening depth in compound and diffusion layers. For the nitrided in 30% nitrogen and post oxidized specimen at $500^{\circ}C$ for 1 hour, the wear resistance was lower than that of the only nitrided one in 30% nitrogen but higher than those of the nitrided ones in 50 and 70% nitrogen.

  • PDF

Effect of Whole-body gamma-Irradiation on Blood Picture in Mice (Cobalt-60 gamma선(線) 전신조사(全身照射)가 생쥐의 혈액상(血液像)에 미치는 영향(影響))

  • Sung, Jai Ki;Cheong, Chang Kook
    • Korean Journal of Veterinary Research
    • /
    • v.15 no.2
    • /
    • pp.153-159
    • /
    • 1975
  • In order to investigate the effect of cobalt-60 gamma irradiation on the blood picture, the mice were subjected to single whole-body gamma irradiation externally. In this experiment 42 of 12 weeks old white mice were used and animals were allotted to group of three. On of chose groups served as control and the others as test groups that were exposed to single dose of 370 Rads (group I) and 500 Rads (group II). The exposure dose rate were averaged 33 Rads per Minute. The results obtained in this experiment were as follows: 1. Erythrocyte counts in both test groups dropped to the lowest level at 4 weeks postirradiation, returning towards the control level, but in recovery, group I showed rather prumpt compared with group II. Erythrocyte count in group II was significantly lower than that of group I. 2. Total leukocyte counts dropped to the lowest loved at 2 weeks postirradiation and group I recovered to normal level at 4 weeks postirradiation. Recovery group II was very slow and it reached to the control level on 12 weeks postirradiation. Leukocyte count was significantly different between group I and II. 3. Neutrophil count was increased to the highest level at 2 weeks postirradiation, with recovery to normal value after 8 weeks in group I and 12 weeks in group II, respectively. Neutrophil count was significantly different between group I and II. 4. Lymphocyte count dropped to the lowest level at 2 weeks postirradiation, with recovery to normal average after 8 weeks in group I and 12 weeks in group II, respectively. Lymphocyte count was significantly different between group I and II. 5. The other leukocyte count was increased after the irradiation and recovered at 12 weeks postirradiation in both test groups. The other leukocyte count was significantly different between group I and II.

  • PDF

A New Aluminium Container for $\gamma$-Ray Spectrometry Analysis of Radium and Radon (라듐 및 라돈의 감마선 분광 분석을 위한 알루미늄 용기의 제작 및 특성 조사)

  • Lee, Kil Yong;Yoon, Yoon Yeol;Seo, Bum Kyoung
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.743-750
    • /
    • 2000
  • For the ${\gamma}$-ray spectrometry analysis of radium and radon in environmental samples, plastic Marinelli beakers have been usually used. But, there are two problems; one is the increment of background by adsorption of airborne radon daughters on the plastic beaker, and other is the incompleteness of radioactive equilibrium by the loss of gaseous radon produced during the radioactive equilibrium process. In order to solve these problems, we made aluminium counting container, and investigated its characteristics. We investigated radioactive equilibrium process using the aluminium container. We found that both solid and liquid samples reached at radioactive equilibrium state in the aluminium container without loss of gaseous radon. By the use of the aluminium container, we established radon and radium analysis method of solid and liquid samples using gamma-ray spectrometry.

  • PDF