• Title/Summary/Keyword: ${\gamma}$-set

Search Result 291, Processing Time 0.024 seconds

Analytical method of New POPs in environmental samples (환경 중 신규 POPs 분석방법 고찰)

  • Shin, Sun-Kyoung;Park, Jin-Soo;Kang, Young-Yeul;Lee, Su-Young;Chun, Jin-Won;Kim, Dong-Hoon;Yeon, Jin-Mo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.128-137
    • /
    • 2010
  • The purpose of this study is to set up the analytical method of new persistent organic pollutants (POPs) such as chlordecone, endosulfan, ${\alpha}$-HCH, ${\beta}$-HCH, ${\gamma}$-HCH. The analytical methods for these compounds listed as new POPs by the Stockholm Convention need to be newly established. Therefore, we proposed the analytical method for 5 organic chlorinated pesticides (OCPs) and then applied the analytical method to environmental samples. To do this, the pre-treatment such as florisil and activated carbon cleanup process in the Korean official method for classic POPs had been reviewed. All of compounds except chlordecone were pre-treated simultaneously with reviewed cleanup process and detected by GC/MS and HRGC/HRMS respectively. There is a problem that chlordecone could not get a high sensitivity by GC analysis, but in this study GC/MS method was proposed.

Discrepancies between Calculated and Delivered Dose Distributions of Respiratory Gated IMRT Fields according to the Target Motion Ranges for Lung and Liver Cancer Patients (호흡연동방사선치료시 폐암과 간암환자의 병소 움직임 크기에 따른 선량분포 차이 분석)

  • Kim, Youngkuk;Lim, Sangwook;Choi, Ji Hoon;Ma, Sun Young;Jeung, Tae Sig;Ro, Tae Ik
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.242-247
    • /
    • 2014
  • To see the discrepancies between the calculated and the delivered dose distribution of IMRT fields for respiratory-induced moving target according to the motion ranges. Four IMRT plans in which there are five fields, for lung and liver patients were selected. The gantry angles were set to $0^{\circ}$ for every field and recalculated using TPS (Eclipse Ver 8.1, Varian Medical Systems, Inc., USA). The ion-chamber array detector (MatriXX, IBA Dosimetry, Germany) was placed on the respiratory simulating platform and made it to move with ranges of 1, 2, and 3 cm, respectively. The IMRT fields were delivered to the detector with 30~70% gating windows. The comparison was performed by gamma index with tolerance of 3 mm and 3%. The average pass rate was 98.63% when there's no motion. When 1.0, 2.0, 3.0 cm motion ranges were simulated, the average pass rate were 98.59%, 97.82%, and 95.84%, respectively. Therefore, ITV margin should be increased or gating windows should be decreased for targets with large motion ranges.

Horizontal Distributions and Their Ecotoxicological Implications Relating to PCBs, DDTs, HCHs, and HCB in Sediments in the West Nakdong River (서낙동강 수계 퇴적물 내 PCBs, DDTs, HCHs 및 HCB의 수평적 분포와 잠재적 생태독성 영향 평가)

  • We, Sung-Ug;Yoon, Cho-Hee;Min, Byung-Yun
    • Journal of Life Science
    • /
    • v.22 no.3
    • /
    • pp.332-339
    • /
    • 2012
  • Horizontal distributions and their ecotoxicological implications relating to organochlorine compounds (OCs) were determined in surface sediments sampled from the West Nakdong River. The concentrations of polychlorinated biphenyls (PCBs), dichlorodiphenyltrichloroethanes (DDTs), hexachlorocyclohexanes (HCHs), and hexachlorobenzene (HCB) in surface sediments were in the range of 0.57-3.68, 0.41-8.35, 0.63-1.65, and n.d.-0.56 ng/g, respectively. DDTs represent the major OC in the West Nakdong River. Concentrations of PCBs and DDTs correlate with the total organic carbon (PCBs: r=0.874, p<0.001, and DDTs: r=0.762, p<0.05, respectively), indicating that organic content in the sediments is one of the major factors for influencing horizontal distribution of the organochlorine compounds in this river. Examining the potential poisonous character of the surface sediments to benthic organisms according to the sediment quality guideline (SQG), set out by the Canadian Council of Ministers of the Environment (CCME) and the National Oceanic and Atmospheric Administration (NOAA), we found that the concentrations of total PCBs, p,p'-DDD, and ${\gamma}$-HCH were lower than the effects range-low (ER-L) and the probable effects level (PEL). As a result, it is considered that the effect of organochlorines in the region considered on benthic organisms is very low from the perspective of environmental toxicology. However, in terms of the Canadian SQC, p,p'-DDE, p,p'-DDT, and total DDTs, respectively, exceeded the interim sediment quality guidelines (ISQG) and the threshold effect level (TEL) in 30%, 17%, and 19%, respectively, of the sediment samples analyzed.

A Study on the Secondary Carcinogenesis Rate of Vestibular Schwannoma Disease using Glass Dosimeter (유리선량계를 이용한 청신경초종 질환의 2차 발암률에 관한 연구)

  • Joo-Ah Lee;Gi-Hong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.243-248
    • /
    • 2023
  • This study aims to analyze the secondary carcinogenesis rate caused by exposure of organs at risk of damage using a glass dosimeter during radiosurgery in vestibular schwannoma disease. Using a pediatric phantom of human tissue equivalent material, the volume of the tumor was set to a total of three volumes: 0.506 cm3, 1.008 cm3, and 2.032 cm3, and a radiosurgery plan was established with an average dose of 18.4 ± 3.4 Gy. After mounting the human body phantom on the table of surgical equipment, glass dosimeters were placed on the right eye, left eye, thyroid gland, thymus, right lung, and left lung to measure the exposure dose, respectively. In this study, the incidence of secondary cancer due to exposure to damaged organs during gamma knife radiosurgery in vestibular schwannoma disease with the largest tumor volume of 2.032 cm3 was measured with a glass dosimeter. This study studies the risk of secondary radiation exposure dose that can occur during stereotactic radiosurgery, and it is considered that it will be used as basic data in the field of radiation damage related to the stochastic effect of radiation in the future.

Radioactive Concentrations in Chemical Fertilizers

  • Gwang-Ho Kim;Jae-Hwan Cho
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.195-203
    • /
    • 2022
  • Background: The aim of the present study was to determine radioactive concentrations in fertilizers known to contain essential nutrients. Results of this study could be used as basic data to monitor the impact of chemical fertilizers on the environment and public health. Nitrogen fertilizers, calcium fertilizers, sulfur fertilizers, phosphate acid fertilizers, and potassium chloride fertilizers were used in this study. Materials and Methods: Five chemical fertilizers were pulverized, placed in polyethylene containers, and weighed. The time to measure each specimen was set to be 3,600 seconds for a scintillator-based gamma-ray spectroscopy system. Concentration of gamma radionuclide was analyzed based on obtained spectra. At the end of the measurement, the spectrum file was stored and used to calculate radioactive concentrations using a gamma-ray spectrometer software. Results and Discussion: In the nitrogen fertilizer, 3.49 ± 5.71 Bq/kg of 137Cs, 34.43 ± 7.61 Bq/kg of 134Cs, and 569.16 ± 91.15 of 40K were detected whereas 131I was not detected. In the calcium fertilizer, 5.74 ± 4.40 Bq/kg of 137Cs (the highest concentration among all fertilizers), 22.37 ± 5.39 Bq/kg of 134Cs, and 433.67 ± 64.24 Bq/kg of 40K were detected whereas 131I was not detected. In the sulfur fertilizer, 347.31 ± 55.73 Bq/kg of 40K, 19.42 ± 4.53 Bq/kg of 134Cs, 2.21 ± 3.49 of 137Cs, and 0.04 ± 0.22 Bq/Kg of 131I were detected. In the phosphoric acid fertilizer, 70,007.34 ± 844.18 Bq/kg of 40K (the highest concentration among all fertilizers) and 46.07 ± 70.40 Bq/kg of 134Cs were detected whereas neither 137Cs nor 131I was detected. In the potassium chloride fertilizer, 12,827.92 ± 1542.19 Bq/kg of 40K was and 94.76 ± 128.79 Bq/kg of 134Cs were detected whereas neither 137Cs nor 131I was detected. The present study examined inorganic fertilizers produced by a single manufacturer. There might be different results according to the country and area from which fertilizers are imported. Further studies about inorganic fertilizers in more detail are needed to create measures to reduce 40K. Conclusion: Measures are needed to reduce radiation exposure to 40K contained in fertilizers including phosphoric acid and potassium chloride fertilizers.

How about IRMA Curve (IRMA 법 Curve에 관하여)

  • Chang, Hyunyeong;Sin, Sunyoung;Lee, Hyunju;Woo, Jearyong;Lee, Hoyoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose : IRMA method for the experimental reagents, as set out in the manual settings for doing and reporting the test results should, in principle. But many of the reagents allows for the setting of the plot does not have a lot of information. Depending on the angle setting of the table make a difference in test results and what settings are best suited to investigate. Materials and Methods : The hospital has Boramae DREAM10, Cobra, SR-300's using the Immunotech TSH reagents have been compared with the measurements. Since then there using EXCEL calculation of the equipment compared with the measurement. Results : In the comparison between each piece of equipment 1.SR-300: DREAM 10 y = 1.1376x - 0.046 (LOG-LOGIT), 2.SR-300: COBRA y = 1.0985x + 0.042 (LOG-LOG) 3.DREAM10: COBRA y = 0.965x + 0.0887 (LOG-LOG) was the result. In all charts the same X, Y axis, X values were good in general when you have. Linear-Logit value of Cobra Dream10 and Excel tends to match the calculated values provided. Conclusion : Is to guide the B / max, B / Total Logit Y axis of the chart is set to draw a look at the value equation when the X-axis LOG a high concentration are disadvantages rising urgently toward the slope. Linear-Logit plots close to the straight line has a curve. If you have a chart to guide on setting AS setting and therefore, set to guide the absence of information on the need to set up the experiment are thought to pass through.

  • PDF

Development and Performance Estimation of Wide-ranged Fine Current Module for NPP Instrumentation (원전 계측용 광범위 미세전류모듈의 개발 및 성능평가)

  • Kim, Jong-ho;Chang, Hong-ki;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.5
    • /
    • pp.482-489
    • /
    • 2016
  • Detection of gamma ray can be available using optical fiber scintillator under radiation environment. It monitors the transfer energies of these ions by photodiodes and then convertes into currents. The module which converts those currents into voltages and processes signals is named fine current module TIA, and it is essentially important to convert currents into voltages with high linearity. We have studied and developed the TIA, improving converting linearity and minimizing noises and off-set voltages. Also, we have made efforts to develop precise and accurate current module in compliance with concerned requirements. First of all, we established developing theory, developed related circuits, and then made the current module. And, we confirmed its stability and linearity to be more excellent than any other equipment proposed by other references. We tested the developed fine current modules in the real radiation environment under authorized supervising, confirmed them to meet related requirements.

Panax ginseng Extract as Protectant in Mercuric Chloride Induced Alterations in Protein Biochemistry in the Serum of Albino Rats

  • Mahour, K.;Saxena, Prabhu-N.;Kumar, Ashok
    • Journal of Ginseng Research
    • /
    • v.30 no.3
    • /
    • pp.106-111
    • /
    • 2006
  • Adverse changes in individual's biochemistry under heavy metal stress are directly linked with its metabolic activity and health status. The present investigation highlights the differences in protecting role of Panax ginseng extract against mercuric chloride induced alterations in serum proteins. The assessment was based on dividing fifty albino rats into two sets, one for acute and the other for sub-acute study. All the sets had five groups with five albino rats in each i.e. control group, mercuric chloride treated group, Panax ginseng extract treated group, mercuric chloride followed by Panax ginseng extract treated group and Panax ginseng extract followed by mercuric chloride treated group. Mercuric chloride was given orally 0.926 mg/kg body weight for acute set and 0.044 mg/kg body weight for sub-acute set after LD50 (9.26 mg/kg body weight) determination by probitt analysis. 10 mg/kg body weight Panax ginseng extract was given in both acute and sub-acute sets after incorporating safety trials. The control group received tween-20 and distilled water only. The result exhibited significantly reduction (P<0.01) in serum protein, albumin and globulin following mercuric chloride intoxication whereas significant (P<0.01) enhancement in other groups with Panax ginseng extract as an ingredient confirming its protective role. All serum samples were also electrophoresed in 10% SDS with standard marker using discontinuous buffering system. Gradual disappearance of alpha-2 and beta-1 globulin bands from electrophoretic pattern was observed, while a single sharp band was observed between beta-2 and gamma globulin in serum protein pattern of acutely mercuric chloride treated rats. However, this band could not be visualized in sub-acute studies. Panax ginseng extract exhibits a better protection after acute intoxication.

The Evaluation of Lateral Scatter Ray of Gamma Camera (Gamma Camera에 있어 측면 선란선의 영향에 대한 평가)

  • Kim, Jae-Il;Lee, Eun-Byeol;Cho, Seong-Wook;Noh, Kyeong-Woon;Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.46-50
    • /
    • 2018
  • Purpose Generally, a collimator that installed in front of detector set a direction of gamma ray and remove a scatter ray. By the way, a lateral or oblique scatter ray is detected into crystal through collimator. At this study, we will evaluate a mount of count and spectrums of lateral scatter ray. Materials and Methods We used the SKY LITE (philips, netherlands) as a gamma camera, and $^{99m}Tc$, 1.11 GBq point source as a phantom. we put this point source at backside 50 cm of detector. After acquiring this for 1 min, we turned a detector next 10 degrees. Likely this, we acquired images at every 10 degrees from $0^{\circ}$ to $360^{\circ}$, analyzed images and spectrums. In case of patient study, we choose a 3 phase bone scan patient who had a hand disease, because scatter rays from body would detect on crystal. After acquiring blood flow and blood pool images, we analyzed images and spectrums. Additional, we put a lead gown on patient's hand, body. And then we compared and evaluated 3 type blood pool images (non lead gown, lead gown on a hand and on body). Results In case of phantom study, scatter ray counts at backside ($270^{\circ}-90^{\circ}$) are same with a background count. By the way, counts of scatter ray of oblique side ($0^{\circ}-50^{\circ}$, $220^{\circ}-270^{\circ}$) are 100-600 cps, furthermore, counts at frontside are over 4 Mcps. In case of patient study, a counts of hand blood pool scan are 1510 cps. But counts of hand with lead gown on hands and on body are each 1554 cps, 1299 cps. Conclusion Therefore, even though there is a collimator in front of detector, lateral scatter rays detect on crystal and affect to images and spectrums. Especially, if there is a high activity source at outside of detector when we examine low activity organs like hands or foot, we have to shield and remove the source at outside for a good image.

Effectiveness of the neutron-shield nanocomposites for a dual-purpose cask of Bushehr's Water-Water Energetic Reactor (VVER) 1000 nuclear-power-plant spent fuels

  • Rezaeian, Mahdi;Kamali, Jamshid;Ahmadi, Seyed Javad;Kiani, Mohammad Amin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1563-1570
    • /
    • 2017
  • In order to perform dry interim storage and transportation of the spent-fuel assemblies of the Bushehr Nuclear Power Plant, dual-purpose casks can be utilized. The effectiveness of different neutron-shield materials for the dual-purpose cask was analyzed through a set of calculations carried out using the Monte Carlo N-Particle (MCNP) code. The dose rate for the dual-purpose cask utilizing the recently developed materials of $epoxy/clay/B_4C$ and $epoxy/clay/B_4C/carbon$ fiber was less than the allowable radiation level of 2 mSv/h at any point and 0.1 mSv/h at 2 m from the external surface of the cask. By utilization of $epoxy/clay/B_4C$ instead of an ethylene glycol/water mixture, the dose rates on the side surface of the cask due to neutron sources and consequent secondary gamma rays will be reduced by 17.5% and 10%, respectively. The overall dose rate in this case will be reduced by 11%.