• 제목/요약/키워드: ${\gamma}$-rays

검색결과 606건 처리시간 0.024초

GPS QUASARS AS SPECIAL BLAZARS

  • BAI J. M.;LEE MYUNG GYONG
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.125-128
    • /
    • 2005
  • In this paper, we argue that the gigahertz peaked spectrum (GPS) quasars are special blazars, blazars in dense and dusty gas enviornment. The ROSAT detection rate of GPS quasars is similar to that of flat spectrum radio quasars (FSRQs), suggesting that the relativistic jets in GPS quasars are oriented at small angle to the line of sight. Due to strong inverse Compton scattering off infrared photons from dense and dusty nuclear interstellar media in GPS quasars, most of them may have significant soft gamma-ray and X-ray emission, which is consistent with ASCA X-ray observations. Because Compton cooling in GPS quasars is stronger than that in FSRQs, synchrotron emission in GPS quasars may less dominate over thermal emission of the accretion disk and hot dust, hence most GPS quasars show low optical polarization and small variability, consistent with observations. We suggest that it is the significant radio emission of electron/positron pairs produced by the interaction of gamma-rays with the dense gas and dust grains in GPS quasars that makes GPS quasars show steep radio spectra, low radio polarization, and relatively faint VLBI/VLBA cores. Whether GPS quasars are special blazars can be tested by gamma-ray observations with GLAST in the near future, with the detection rate of GPS quasars being similar to that of FSRQs.

단일 보너구와 TLD-600 및 TLD-700을 이용한 Cf-252의 중성자 에너지 스펙트럼 평가 (Estimation of Neutron Energy Spectrum of Cf-252 using Single Bonner Sphere with TLD-600 and TLD-700)

  • 김성환;천종규;이재진;남욱원
    • 센서학회지
    • /
    • 제22권3호
    • /
    • pp.223-226
    • /
    • 2013
  • We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from $10^{-1}$ to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.

100-MeV 양성자 빔을 이용하여 169Tm(p,3n)167Yb 반응에 의해 생성된 167Yb 방사성동위원소에서 방출되는 감마선 스펙트럼 비교 연구 (A Comparative Study of Branching Ratio of 167Yb Radioactive Isotope from Gamma-ray Spectrum Produced by 169Tm(p,3n)167Yb Reaction with 100-MeV Proton Beam)

  • 이삼열
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.953-960
    • /
    • 2022
  • 양성자과학연구단의 100-MeV 양성자선형가속기의 양성자를 사용하여 천연 169Tm과 핵반응을 일으켜 167Yb 방사성동위원소를 생성하였다. 생성된 동위원소는 17.5분의 반감기를 가지며 167Tm로 붕괴한다. 이때 발생하는 감마선을 HPGe 검출시스템을 사용하여 측정하였다. 검출기의 에너지 교정 및 검출기의 효율 측정은 표준선원을 사용하여 결정하였다. 기존에 알려진 Table of Isotopes의 주요 감마선 에너지는 모두 측정되었다. 한편, 현재까지 알려진 발생되는 감마선의 강도에 대한 정보는 매우 부정확한 상황이다. 따라서 본 연구를 통하여 주요 감마선에 대한 붕괴 강도를 정확하게 측정하였다. 전체적으로 기존에 알려져 있던 결과들과 상이한 차이를 보였으며 특히 113.3 및 106.2 keV 감마선 같은 주 붕괴 감마선의 강도들이 과대평가 되었다는 사실을 알게 되었고 62.9, 116.7 및 143.56 keV의 감마선 들은 과소평가 된 감마선들임을 알게 되었다. 본 연구의 결과는 핵융합 연구, 천체 물리학 및 핵물리 분야에 있어서 중요한 정보가 될 것으로 생각된다.

CMOS 소자에서 과도방사선펄스에 의한 Dose-Rate Latchup 모의실험 (Simulation for Dose-Rate Latchup by Transient Radiation Pulse in CMOS Device)

  • 이현진;이남호;황영관
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1185-1186
    • /
    • 2008
  • A nuclear explosion emits a transient radiation pulse like gamma rays. Gamma rays have a high energy and cause unexpected effects in semiconductor devices. These effects are mainly referred to dose-rate latcup and dose-rate upset. By transient radiation pulse in CMOS devices, dose-rate latchup is simulated in this paper.

  • PDF

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.

양성자 에너지 변화에 따른 핵반응 생성핵종 분석 (Analysis of Proton Nuclear Reaction-Generated Nuclides for Different Proton Energy)

  • 이삼열
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.819-824
    • /
    • 2019
  • 본 연구에서 서로 다른 양성자 에너지를 사용하여 핵반응에 의해 생성된 감마선의 차이를 통해 고에너지 양성자 Pb(p, nx) 핵반응에서 생성된 동위원소를 식별하는 방법을 제안했다. 한국원자력연구원의 100-M eV 양성자 선형 가속기에서 생성된 고 에너지 양성자를 이용하여 실험을 수행 하였다. 양성자 핵반응을 통해 생성된 다양한 핵종에 의해 생성된 감마선은 HPGe 검출기로 구성된 감마선 분광법 시스템을 사용하여 측정되었습니다. 감마선 표준선원은 감마선 검출기의 정확한 에너지교정 및 효율측정을 위해 사용되었습니다. 제안한 방법을 위하여 동일한 천연 납 시료에 서로 다른 100 및 60 MeV 양성자 에너지빔을 사용하였다. 이 방법은 동일한 시료에서 발생되는 감마선들을 서로 비교함으로써 생성된 핵종들을 확인하는데 매우 효과적임을 알 수 있었다. 이 연구의 결과는 향후 다른 양성자 핵반응 결과를 얻는데도 매우 효과적으로 적용될 것이라 생각된다.

CHO 세포에서의 소핵시험을 이용한 감마선조사 생약재의 안전성에 관한 유전독성학적 평가 (Genotoxicological safety of the Gamma-Irradiated Medicinal Herbs in the Micronucleus Test Using CHO Cells In Vitro)

  • 조성기
    • 한국식품영양과학회지
    • /
    • 제26권5호
    • /
    • pp.952-957
    • /
    • 1997
  • The three medicinal herbs-Curcuman longa Linne, Paeonia japonica Miyabe, Scutellaria baikalensis George-irradiated with gamma rays were tested for their possible genotoxicity. The methanol-soluble and water-soluble fractions of the 10kGy gamma-irradiated herbs were examined in cultured Chinese hamster ovary(CHO) cells for their ability to induce micronuclei. No mutagenicity of each test material was detected in the assay with or without metabolic activation. The safety of the herbs irradiated with gamma rays at practical doses needs further investigations using in vivo genotoxicity and chronic and reproductive toxicity tests.

  • PDF

복귀돌연변이시험을 이용한 감마선조사 생약재의 안전성에 관한 유전독성학적 평가 (Genotoxicological Safety of the Gamma Irradiated Medicinal Herbs in the salmonella typhimurium Reversion Assay)

  • 조성기;육홍선;변명우
    • 한국식품영양과학회지
    • /
    • 제26권5호
    • /
    • pp.958-964
    • /
    • 1997
  • The three medicinal herbs-Curcuma longa Linne, Paeonia japonica Miyabe, Scutellaria baikalensis George-irradiated with gamma rays have been tested for their possible genotoxicity. The methanol-soluble and water-soluble fractions of the 10kGy gamma-iradiated herbs were examined in the Salmonella typhimurium histidine reversion assy(Ames test) using S. typhimurium TA98, TA100 and TA102 as tester strains. No mutabenicity was detected in this assay with or without metabolic activation. The safety of the herbs irradiated with gamma rays at practical doses needs to be evaluated in further tests of genotoxicity in vivo and chronic and reproductive toxicity.

  • PDF

감마선 조사 생약재의 안전성에 관한 유전독성학적 평가 (Genotoxicological Safety of the Gamma-Irradiated Medicinal Herbs)

  • 조성기
    • 한국식품위생안전성학회지
    • /
    • 제12권3호
    • /
    • pp.217-227
    • /
    • 1997
  • These experiments were performed to investigate the safety of the three medicinal herbs- Curcuma longa Linne, Paeonia japonica Miyabe, Scutellaria baikalensis George-irradiated with gamma rays in respect of genotoxicity. The methanol-soluble and water-soluble fractions of the methanol-water extracts of the 10 kGy gamma-irradiated herbs were examined in two short-term in vitro tests : (1) Salmonella typhimurium reversion assay (Ames test) in strain TA 98, TA 100 and TA 012 (2) Micronucleus test in cultured Chinese hamster ovary (CHO) cells. No mutagenicity was detected in the assays with or without metabolic activation. From these results, the safety of the herbs irradiated with gamma rays at practical doses could be revealed in further tests of genotoxicity in vivo, chronic and reproductive toxiceity.

  • PDF