• Title/Summary/Keyword: ${\gamma}$-Ray radiation

Search Result 886, Processing Time 0.024 seconds

A Study on Radiation Hardening of a Infrared Detector (적외선 탐지소자의 내방사선화 연구)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.490-492
    • /
    • 2005
  • A study on radiation hardening of infrared(IR) detector, the chief component of IR camera was performed. The radiation test on IR sensor passivated with the ZnS by Co$^{60}$ gamma-ray over 1 Mrads showed the reduction in Ro by 1/100 which was related to the noise level. This effect that was caused by carrier trapping in the ZnS passivation layer increased the leakage current and resulted in degradation in the device performance. For the radiation hardening of IR devices we suggested the ones with CdTe passivation layer which had a tendency to reluctant to carrier trapping in its layer and developed test patterns. Radiation test to the patterns showed that the our CdTe passivated device could survived over 1 Mrad gamma-ray dose.

Comparison of Three Radiation Sources on Quality Properties of Three Dried Condiments (건조 향신료 3종에 대한 방사선종별 조사효과 비교)

  • Park, Kyung-Sook
    • Journal of Radiation Industry
    • /
    • v.8 no.2
    • /
    • pp.83-88
    • /
    • 2014
  • Application of X-ray irradiation of dried condiments was studied using commercially prepared dried garlic, onion and welsh onion flakes as model samples. Total load of aerobic microbes (TAM), color differences, and generation of off-flavor were quantified for samples individually irradiated with gamma rays, electrons, or X-rays. TAM load was decreased by irradiation in a dose-dependent manner. The three types of radiation did not differ in the extent of TAM reduction (P>0.05). The samples did not differ in color. Off-flavor was detected from 6 kGy-irradiated samples, regardless of radiation sources. The results indicated that X-ray irradiation could be used for irradiation of dried condiments with the same effects as gamma rays and an electron beam.

Influence of the Low Dose ${\gamma}$-ray Radiation on the Old Seed Germination and Growth of Chinese Cabbage (묵은 배추종자의 발아와 생육에 미치는 저선량 ${\gamma}$선 효과)

  • 김재성;이영근;백명화;이영복;박영선
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.1
    • /
    • pp.11-15
    • /
    • 1999
  • To investigate the stimulating effects of the low- dose radiation, the seeds of chinese cabbages (Brassica campestris L. cv. Hanyoreum and cv. Tropic emperor) were irradiated at the dose of 0.5 Gy~20 Gy with the ${\gamma}$-ray radition. In case of ‘Hanyoreum’cultivar, there were no significant promoting effects on the germination rate except the 0.5 Gy irradiated group. The increase in seedling height and fresh weight in 8 Gy and 12 Gy irradiated groups was 20% and 40%, respectively, which suggested the stimulating effect of the low-dose radiation on the early growth. In case of‘Tropic emperor’cultivar, the germination rate of 1 Gy irradiated group increased approximately 10% and the seedling height and fresh weight of 1 Gy and 12 Gy irradiated group in the greenhouse 20% on the average, and plant height and fresh weight of 0.5 Gy and 4 Gy irradiated group in the field increased 10% and 20% on the average, respectively.

  • PDF

Preparation and Characterization of Polyvinylpyrrolidone/${\kappa}$-Carrageenan/Hexanediol Hydrogel by Gamma-ray Irradiation (감마선을 이용한 폴리비닐피롤리돈/카파-카라기난/1,2-헥산디올 하이드로젤의 제조 및 특성)

  • Han, Il-Soo;Lim, Youn-Mook;Gwon, Hui-Jeong;Park, Jong-Seok;Nho, Young-Chang
    • Polymer(Korea)
    • /
    • v.35 no.1
    • /
    • pp.13-16
    • /
    • 2011
  • In this study, the hydrogels composed of polyvinylpyrrolidone (PVP), ${\kappa}$-carrageenan (${\kappa}C$), and 1,2-hexanediol (HD) were prepared by ${\gamma}$-ray irradiation. The radiation dose was 25 kGy and the concentration of ${\kappa}C$ was 3 wt%. The physical properties of the hydrogels were investigated as a function of the concentrations of PVP and HD. The gel content and the tensile strength increased with increasing PVP concentration due to the crosslinking between the pyrrolidone molecules and decreased with increasing HD concentration. The degree of swelling was inversely proportional to the gel content because the highly crosslinked hydrogels had a tighter structure, hence reducing their water absorption. The antibacterial tests indicated that the hydrogels containing HD had antibacterial activity.

Generation of Gamma-Ray Streaming Kernels Through Cylindrical Ducts Via Monte Carlo Method (몬테칼로 방법을 이용한 원통형 관통부의 감마선 스트리밍 커널의 산출)

  • Kim, Dong-Su;Cho, Nam-Zin
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.80-90
    • /
    • 1993
  • Radiation streaming through penetrations has been of great concern in radiation shielding design and analysis. This study developed a Monte Carlo method and constructed a data library of results calculated by the Monte Carlo method for radiation streaming through a straight cylindrical duct in concrete walls of a broad, mono-directional, mono-energetic gamma-ray beam of unit intensity. It was demonstrated that average dose rate due to an isotropic point source at arbitrary positions can be well approximated using the library with acceptable error. Thus, the library can be used for efficient analysis of radiation streaming due to arbitrary distributions of gamma-ray sources.

  • PDF

Region-wise evaluation of gamma-ray exposure dose in decontamination operation after a nuclear accident

  • Jeong, Hae Sun;Hwang, Won Tae;Han, Moon Hee;Kim, Eun Han;Lee, Jo Eun;Lee, Cheol Woo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2652-2660
    • /
    • 2021
  • The gamma-ray exposure doses in decontamination operation after a nuclear accident were evaluated with a consideration of various geometrical conditions and specific gamma-ray energies. The calculation domain is organized with three residence types and each form is divided into two kinds of geometrical arrangements. The position-wise air KERMA values were calculated with an assumption of evenly distributed gamma-ray source based on Monte Carlo radiation transport analysis using the MCNP code. The radioactivity is initially set to be unity to be multiplied by the deposition value measured in the actual accident condition. The workforce data set depending on the target object was determined by modifying the Fukushima report. The external exposure doses for decontamination workers were derived from the calculated KERMA values and the workforce analysis. These results can be used to efficiently determine the workforce required by the characteristics of the area and the structure to be decontaminated within the dose limits.

Radio-quiet Gamma-ray Pulsars

  • Lin, Lupin Chun-Che
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.147-166
    • /
    • 2016
  • A radio-quiet γ-ray pulsar is a neutron star that has significant γ-ray pulsation but without observed radio emission or only limited emission detected by high sensitivity radio surveys. The launch of the Fermi spacecraft in 2008 opened a new epoch to study the population of these pulsars. In the 2nd Fermi Large Area Telescope catalog of γ-ray pulsars, there are 35 (30 % of the 117 pulsars in the catalog) known samples classified as radio-quiet γ-ray pulsars with radio flux density (S1400) of less than 30 μJy. Accompanying the observations obtained in various wavelengths, astronomers not only have the opportunity to study the emitting nature of radio-quiet γ-ray pulsars but also have proposed different models to explain their radiation mechanism. This article will review the history of the discovery, the emission properties, and the previous efforts to study pulsars in this population. Some particular cases known as Geminga-like pulsars (e.g., PSR J0633+1746, PSR J0007+7303, PSR J2021+4026, and so on) are also specified to discuss their common and specific features.

Effect of γ-ray Irradiation on THMs Formation and Water Quality Characteristics in the Chlorination of Humic Acid Contaming Water (감마선 조사가 휴민산 염소화에 의한 THMs 생성능 및 수질특성에 미치는 영향)

  • Kang, Chul-ho;Lim, Hyun-woo;Jung, Sung-woon;Choi, Jong-hyuk;Kim, Jong-hoon;Choi, Yong-wook;Lee, Myun-joo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1034-1039
    • /
    • 2010
  • Variation of formation potential of THM (THMFP) by chlorination of humic acid and characteristics of water quality with ${\gamma}$-ray irradiation were investigated, which were divided into two categories by the order of ${\gamma}$-ray irradiation and chlorination in water treatment process. The group A consisted of the ${\gamma}$-ray irradiation followed by chlorination process of humic acid, and the group B consisted of the chlorination followed by ${\gamma}$-ray irradiation process. The pH, ORP, $UV_{254}$, and DOC decreased rapidly with an increase in ${\gamma}$-ray irradiation of 3 kGy. while conductivity was little changed. Maximum degradation ratio of chloroform in THMs of group A was 82%, while that in group B was 69%. No brominated THMs were detected at high irradiation (>3 kGy). We found that group A water treatment process was more effective in lowering the THMFP than that of group B.

A Study of Tissue-equivalent Compensator for 10MV X-ray and Co-60 Gamma-ray (고에너지 방사선치료용 조직등가보상체에 관한 고찰)

  • CHOI Tae Jin;HONG Young Rak;LIM Charn Soo;JEUNG Ho Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 1985
  • Authors describe some useful data when constructing tissue-equivalent compensators which would compensate tissue deficit in the treatment field of high energy electromagnetic radiation Tissue equivalent compensator is made of lucite. The ratio of compensator thickness to the thickness of tissue deficit depends on radiation energy, field size and the distance from the compensator to patient skin. When the compensator is separated from skin surface, the thickness ratio is always smaller than 1.0. This means that the larger the separation, the contribution to the total dose by means of scattered radiation from a tissue equivalent compensator is smaller. Authors propose that the thickness of lucite as tissue equivalent compensator is 0.57 times tissue deficit and the separation between compensator and skin is at least 15m for Co-60 gamma ray and 25cm for 10MV X-ray.

  • PDF