• Title/Summary/Keyword: ${\delta}$-변환

Search Result 172, Processing Time 0.03 seconds

SUPERSTRUCTURES OF Bi-Sr-Ca-Cu-O SUPERCONDUTORS (Bi-Sr-Ca-Cu-O계열 초전도체의 초구조)

  • Nam, Gung-Chan;Lee, Sang-Yun
    • Korean Journal of Materials Research
    • /
    • v.4 no.3
    • /
    • pp.268-279
    • /
    • 1994
  • The x-ray powtler pattern of single phase $Bi_2S_2CaCu_2O_{8+x}$ has been identified and fullyindexed using a pseudotetragonal subcell with a= 5.408, c = 30.83 $\AA$ and an incommensurate supercellwith reciprocal lattice vector, X$q^*$, given by $q^*=0.211b^*-c^*$. The x -ray powder pattern of the Pb-free110K superconductor phase "$Bi_2S_2CaCu_2O_{10+x}$" has many lines which belong t.o an incommensuratesupercell. Using elect.ron d~ffraction pImt.ographs as a indexing guide, an indexing scheme for the powderpattern has been obtained. The unit cell has a geometrically orthorhombic subcell a=5.411, b= 5.420, c=37.29(2) $\AA$. Supercell reflections have indices that are derived from the subcell k, 1 indices by addition uf$\pm q^*$, where $\pm q^*=0.211b^*-0.78c^*$The incommensurate con~ponent In the b dwection, $\delta$, is the same for both phases but on going from2212 to 2223 phase, the superlattic component in the c direction changes from commensurate($\varepsilon$=1) toincommensurate($\varepsilon$=0.78).X>$\varepsilon$=0.78).

  • PDF

Organic Analysis of Charred Residues on the Pottery in the Proto-Three Kingdom from Joong-do Site, Chuncheon (춘천 중도 유적에서 출토된 원삼국시대 토기 탄착물에 대한 화학적 분석)

  • Kang, Soyeong;Jee, Sanghyun;Kim, Yun Ji;Chang, Hong Sun
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.437-444
    • /
    • 2013
  • We studied for the chemical characterizations of the charred residues obtained from the ancient potteries in the Proto-Three Kingdom period from archaeological sites in Joong-do, Chuncheon. Organic components of the charred residues were extracted and analysed using mass spectrometry and infrared spectroscopy. Lipid profiles from these samples were not identified in gas chromatography-mass spectrometry. Bulk stable isotope analyses of charred residues was used to infer an average values of the foods prepared. The average carbon isotope values (${\delta}^{13}C$) of the residues are $-14.7{\pm}2.8$‰ (ranging from -8.7‰ to -18.4‰, n=9), and nitrogen isotope values (${\delta}^{15}N$) are $6.2{\pm}1.1$‰ (ranging from -4.4‰ to -7.6‰, n=9). This is the first approach to analyse charred residues using stable isotopic method in Korea. Charred food residues on the interior surface of archaeological pottery can provide valuable information about pottery use and dietary habits of its population.

Design of a Holter Monitoring System with Flash Memory Card (플레쉬 메모리 카드를 이용한 홀터 심전계의 설계)

  • 송근국;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.251-260
    • /
    • 1998
  • The Holter monitoring system is a widely used noninvasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we design a high performance intelligent holter monitoring system which is characterized by the small-sized and the low-power consumption. The system hardware consists of one-chip microcontroller(68HC11E9), ECG preprocessing circuit, and flash memory card. ECG preprocessing circuit is made of ECG preamplifier with gain of 250, 500 and 1000, the bandpass filter with bandwidth of 0.05-100Hz, the auto-balancing circuit and the saturation-calibrating circuit to eliminate baseline wandering, ECG signal sampled at 240 samples/sec is converted to the digital signal. We use a linear recursive filter and preprocessing algorithm to detect the ECG parameters which are QRS complex, and Q-R-T points, ST-level, HR, QT interval. The long-term acquired ECG signals and diagnostic parameters are compressed by the MFan(Modified Fan) and the delta modulation method. To easily interface with the PC based analyzer program which is operated in DOS and Windows, the compressed data, that are compatible to FFS(flash file system) format, are stored at the flash memory card with SBF(symmetric block format).

  • PDF

The Availability of Automobile Catalytic Convert of Copper Based on the DFT Calculations of Cu-NO Complexes (Cu-NO 복합체에 대한 DFT 계산에 따른 Cu의 자동차 촉매변환기 적합성)

  • Ha, Kwanga;Lee, Min-Joo
    • Journal of the Korean Chemical Society
    • /
    • v.62 no.5
    • /
    • pp.358-363
    • /
    • 2018
  • The purpose of this study is to show the possibility of using Cu catalyst in removal of $NO_x$ from automobile exhaust which is regarded as the primary source of fine dust PM2.5. The energy and the bond lengths of the three possible structures of Cu-NO complex, which is formed by binding NO molecule to Cu, and the changes in IR and Raman spectra are calculated using MPW1PW91 method on the level of 6-311(+)G(d,p) of basis sets with Gaussian 09 program. As a result, the enthalpy of formation of the Cu-NO complexes are obtained as ${\Delta}H=104.89$, 91.98, -127.48 kJ/mol for the linear, bent, and bridging forms of them, respectively. And the bond lengths between N and O in NO complexes, which becomes longer than NO molecule, indicates that O is easily reduced from Cu-NO. In addition, the Cu-NO complexes using Cu catalyst can be easily measured by infrared or Raman spectroscopy because in the IR and Raman spectra of the NO and Cu-NO complexes the positon and the intensity of bands are definitely different in each vibration mode.

Harmonic Reduction of Electric Propulsion System by Current Injection (전류주입에 의한 전기추진시스템의 고조파 저감)

  • Kim, Jong-Su;Han, Won-Hui;Seo, Dong-Hoan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.4
    • /
    • pp.360-364
    • /
    • 2012
  • AC to DC converter that consists of relatively simple diode rectifier devices has been widely used in the field of the electric propulsion system. Also, since this rectifier includes large harmonics in the input current, a variety of researches have been developed to reduce the harmonics. The proposed method of this paper is to reduce the harmonics included in the input current of rectifiers and propulsion motor by injecting the output current of diode rectifier into the input of them. In addition, the proposed method ensures electrical safety through the respective isolation of the injection current, the source, and the loads using the Wye-Delta insulating transformer applied in current injection device that is installed in the input circuit of rectifiers and propulsion motor. The proposed method is simulated by applying to the electric propulsion ship that is currently operating. We confirm the validity of the proposed method compared with conventional power conversion system.

Recognition of the emotional state through the EEG (뇌파를 통한 감정 상태 인식에 관한 연구)

  • Ji, Hoon;Lee, Chung-heon;Park, Mun-Kyu;An, Young-jun;Lee, Dong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.958-961
    • /
    • 2015
  • Emotional expression is universal and emotional state impacts important areas in our life. Until now, analyzing the acquired EEG signals under circumstances caused by invoked feelings and efforts to define their emotional state have been made mainly by psychologists based on the results. But, recently emotion-related information was released by research results that it is possible to identify mental activity through measuring and analyzing the brain EEG signals. So, this study has compared and analyzed emotional expressions of human by using brain waves. To get EEG difference for a particular emotion, we showed specific subject images to the people for changing emotions that peace, joy, sadness and stress, etc. After measured EEG signals were converged into frequence domain by FFT signal process, we have showed EEG changes in emotion as a result of the performance analyzing each respective power spectrum of delta, theta, alpha, beta and gamma waves.

  • PDF

Color Correction Using Polynomial Regression in Film Scanner (다항회귀를 이용한 필름 스캐너에서의 색보정)

  • 김태현;백중환
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.1
    • /
    • pp.43-50
    • /
    • 2003
  • Today, the demand of image acquisition systems grows as the multimedia applications go on increasing greatly. Among the systems, film scanner is one of the systems, which can acquire high quality and high resolution images. However due to the nonlinear characteristic of the light source and sensor, colors of the original film image do not correspond to the colors of the scanned image. Therefore color correction mr the scanned digital image is essential in the film scanner. In this paper, polynomial regression method is applied for the color correction to CIE $L^{*}$ $a^{*}$ $b^{*}$ color model data converted from RGB color model data. A1so a film scanner hardware with 12 bit color resolution for each R, G, B and 2400 dpi was implemented by using TMS320C32 DSP chip and high resolution line sensor. An experimental result shows that the average color difference ($\Delta$ $E^{*}$$_{ab}$ ) is reduced from13.48 to 8.46.6.6.6.6.

Function Embedding and Projective Measurement of Quantum Gate by Probability Amplitude Switch (확률진폭 스위치에 의한 양자게이트의 함수 임베딩과 투사측정)

  • Park, Dong-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1027-1034
    • /
    • 2017
  • In this paper, we propose a new function embedding method that can measure mathematical projections of probability amplitude, probability, average expectation and matrix elements of stationary-state unit matrix at all control operation points of quantum gates. The function embedding method in this paper is to embed orthogonal normalization condition of probability amplitude for each control operating point into a binary scalar operator by using Dirac symbol and Kronecker delta symbol. Such a function embedding method is a very effective means of controlling the arithmetic power function of a unitary gate in a unitary transformation which expresses a quantum gate function as a tensor product of a single quantum. We present the results of evolutionary operation and projective measurement when we apply the proposed function embedding method to the ternary 2-qutrit cNOT gate and compare it with the existing methods.

Design of a Wireless Self-Powered Temperature Sensor for UHF Sensor Tags (무선 전력 구동 센서 태그 내장형 온도센서의 설계)

  • Kim, Hyun-Sik;Cho, Jung-Hyun;Kim, Shi-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.10
    • /
    • pp.1-6
    • /
    • 2007
  • Wireless Self-Powered Temperature Sensor for UHF Sensor Tags which are basic device for construction of ubiquitous sensor network is proposed. The key parameters of the target specification are resolution of $0.1\;^{\circ}C$ per output bit, below 1.5 V of operating voltage and below 5 uW of power consumption during sensing operation. Temperature sensor circuit consists of PTAT current generator, band gap reference circuit generating both reference voltage and current, Sigma-Delta Converter, and Digital Counter. Simulated maximum resolution was $0.23\;^{\circ}C/bit$ in 11-bit output. The proposed temperature sensor was fabricated by using a 0.25 m CMOS process. The chip area is $0.32\;{\times}\;0.22\;mm$ and the operating frequency is 2 MHz. Measured resolution from fabricated temperature sensor was $4\;^{\circ}C/bit$ in 8-bit output for the temperature range from $10^{\circ}C$ to $80^{\circ}C$.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.