• Title/Summary/Keyword: $^{99m}Tc$-MIBI Myocardial SPECT

Search Result 67, Processing Time 0.059 seconds

A Quantitative Method for the Assessment of Myocardial Function using the Polar Analysis of Tc-99m-MIBI Myocardial SPECT (Tc-99m-MIBI 심근 SPECT 극성지도 분석에 의한 심근 기능의 정량적 평가)

  • Kwark, Cheol-Eun;Lee, Dong-Soo;Yeo, Jung-Suk;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.172-176
    • /
    • 1994
  • As the Tc-99m-MIBI myocardial SPECT demonstrated wide application in the diagnosis of myocardial function, the quantitative and severity-dependent information is currently re quired. In this study, we proposed a computerized method for scoring the fixed defects in terms of extent-weighted severity and for identifying the reversibility in ischemic regions. At the first stage of this method, the transverse slices were reconstructed with 0.4 Nyquist freq. and order 5 Butterworth filter. From the oblique/sagittal slices, maximal count per pixel circumferential profiles were extracted for each sector, and then stress/redist. polar maps were normalized and plotted. For reversibility, the stress polar map was subtracted from the de-layed image and positive-valued pixels were categorized into three grades. The extent-weight-ed severity scores were calculated using the assigned grades and their number of pixels. This procedure was done automatically and the reversibility and severity scores were produced for each of the coronary territories (LAD, RCA, LCX) or any combination of these. Clinical ap-plication has shown that the changes In reversibility scores after PTCA were correlated linearly with the pre PTCA scores(r>0.8) in postinfarct cases as well as in angina, and severity scores of persistent defects in stress/rest SPECT study matched to the regional ejection fraction and visual analysis of regional wall motion of gated blood pool scan(r>0.6). We conclude that the computerized severity scoring method for the analysis of myocardial SPECT could be useful in the assessment of the myocardial ischemia and fixed defect.

  • PDF

Prediction of Improvement of Myocardial Wall Motion after Coronary Artery Bypass Surgery Using Rest T1-201/Dipyridamole Stress Gated Tc-99m-MIBI/24 Hour Delay T1-201 SPECT (휴식기 T1-201/디피리다몰 부하 게이트 Tc-99m-MIBI/24시간 지연 T1-201 SPECT를 이용한 관상동맥 우회로 수술 후 심근벽 운동 호전의 예측)

  • Lee, Dong-Soo;Lee, Won-Woo;Yeo, Jeong-Seok;Kim, Seok-Ki;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.497-508
    • /
    • 1998
  • Purpose: Using rest T1-201/dipyridamole stress gated Tc-99m-MIBI/ 24 hour delay T1-201 SPECT, we investigated the predictive values of the markers of the stress-rest reversibility (Rev), T1-201 rest perfusion (Rest), T1-201 24 hour redistribution (Del) and Tc-99m-MIBI gated systolic thickening (Thk) for wall motion improvement after coronary artery bypass surgery. Materials and Methods: In 39 patients (M;F= 34:5, age $58{\pm}8$), preoperative and postoperative (3 months) SPECT were compared. 24 hour delayed SPECT was done in 16 patients having perfusion defects at rest. Perfusion or wall motion was scored from 0 to 3 (0: normal to 3: defect or dyskinesia). Wall motion was abnormal in 142 segments among 585 segments of 99 artery territories which were surgically revascularized. Results: After bypass surgery, ejection fraction increased from $37.8{\pm}9.0%$ to $45.5{\pm}12.3%$ in 22 patients who had decreased ejection fraction preoperatively. Wall motion improved in 103 (72.5%) segments among 142 dysfunctional segments. Positive predictive values (PPV) of Rev, Rest, Del, and Thk were 83%, 76%, 43%, and 69% respectively. Negative predictive values (NPV) of Rev, Rest, Del, and Thk were 48%, 44%, 58%, and 21%, respectively. Rest/gated stress/delay SPECT had PPV of 74% and NPV of 46%. Though univariate logistic regression analysis revealed Rev (p=0.0008) and Rest (p=0.024) as significant predictors, stepwise multivariate test found Rev as the only good predictor (p=0.0008). Conclusion: Among independent predictors obtained by rest T1-201/ stress gated Tc-99m-MIBI/ delayed T1-201 myocardial SPECT for wall motion improvement after bypass surgery, stress-rest reversibility was the single most useful predictor.

  • PDF

Comparison between $180^{\circ}$ and $360^{\circ}$ Data Collection in $^{99m}Tc-MIBI$ Myocardial SPECT ($^{99m}Tc-MIBI$ 심근 SPECT에서 180도와 360도 데이터 집적의 비교)

  • Kang, Keon-Wook;Lee, Dong-Soo;Kwark, Cheol-Eun;Hyun, In-Young;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.478-483
    • /
    • 1995
  • We compared the influences of reconstruction methods using $180^{\circ}$ or $360^{\circ}$ data upon contrasts and discriminating capability and diagnostic accuracy in $^{99m}Tc-MIBI$ stress/rest myocardial SPECT. We reviewed SPECT images reconstructed only with $180^{\circ}$ projection data or with $360^{\circ}$ data in 18 patients and in 11 normal subjects. To compare counts of surface structures and deep structures, we measured ape# posterior wall ratios in 11 normal subjects. To compare the contrasts of images, we measured apex/ventricle ratios. To compare contrasts between normal and diseased myocardial segments, we measured count ratios of defect and normal segments in 4 patients who had single coronary artery diseases. To compare diagnostic accuracy, we scored SPECT images made with $180^{\circ}$ and $360^{\circ}$ data segmentally. Sensitivity and specificity for the diagnosis of coronary artery disease and for the revelation of diseased arteries with both $180^{\circ}$ and $360^{\circ}$ SPECT images. If involved coronary arteries had more narrowing than 50% In coronary angiogram, we considered them as diseased arteries Apex/posterior wall ratios were not different significantly in normal subjects. Apex/ ventricle ratios in normal subjects were different significantly between $180^{\circ}$ and $360^{\circ}$ SPECT images. Defect/normal ratios were different significantly between $180^{\circ}$ and $360^{\circ}$ SPECT images in single vessel disease patients. The overall diagnostic accurracy was the same between $180^{\circ}$ and $360^{\circ}$ data collection. Sensitivity was 94% and specificity was 91% for both types of data collection in this sample population. Sensitivity and specificity of each coronary artery territory were not significantly different between the images made with $180^{\circ}$ and $360^{\circ}$ data. The images made with $180^{\circ}$ data had better contrast between ventricle and myocardium and between hypoperfused and normal myocardium, though no difference was found between the ratios of the myocardial counts of surface and deep structures. However, diagnostic sensitivities of diseased artery territories were not different significantly and so were overall diagnostic accuracy between both methods of making images with $180^{\circ}$ and $360^{\circ}$ data.

  • PDF

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Nitroglycerin-Challenged Tc-99m MIBI Quantitative Gated SPECT to Predict Functional Recovery After Coronary Artery Bypass Surgery (니트로글리세린 투여 Tc-99m-MIBI 정량 게이트 심근SPECT를 이용한 관상동맥우회로술 후 심근 기능 회복 예측)

  • Lee, Dong-Soo;Kim, Yu-Kyeong;Cheon, Gi-Jeong;Paeng, Jin-Chul;Lee, Myoung-Mook;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.278-287
    • /
    • 2003
  • Purpose: The performance of nitroglycerin-challenged Tc-99m-MIBI quantitative gated SPECT for the detection of viable myocardium was compared with rest/24-hour redistribution Tl-201 SPECT Materials and Methods: In 22 patients with coronary artery disease, rest Tl-20l/ dipyridamole stress Tc-99m-MIBI gated/24-hour redistribution Tl-201 SPECT were peformed, and gated SPECT was repeated on-site after sublingual administration of nitroglycerin (0.6 mg). Follow-up gated SPECT was done 3 months after coronary artery bypass graft surgery. For 20 segments per patient, perfusion at rest and 24-hour redistribution, and wall motion and thickening at baseline and nitroglycerin-challenged state were quantified. Quantitative viability markers were evaluated and compared;(1) rest thallium uptake, (2) thallium uptake on 24-hour redistribution SPECT, (3) systolic wall thickening at baseline, and (4) systolic wall thickening with nitroglycerin-challenge. Results: Among 100 revascularized dysfunctional segments, wall motion improved in 66 segments (66%) on follow-up gated myocardial SPECT after bypass surgery. On receiver operating characteristic (ROC) curve analysis, the sensitivity and specificity of rest and 24-hour delayed redistribution Tl-201 SPECT were 79%, 44% and 82%, 44%, respectively, at the optimal cutoff value of 50% of Tl-201 uptake. The sensitivity and specificity of systolic wall thickening at baseline and nitroglycerin-challenge were 49%, 50% and 64%, 65% at the optimal cutoff value of 15% of systolic wall thickening. Area under the ROC curve of nitroglycerin-challenged systolic wall thickening was significantly larger than that of baseline systolic wall thickening (p=0.004). Conclusion: Nitroglycerin-challenged quantitative gated Tc-99m-MIBI SPECT was a useful method for predicting functional recovery of dysfunctional myocardium.

Lung Uptake of $^{99m}Tc-sestamibi$ during Routine Gated Exercise SPECT Imaging : Comparison with Left Ventricular Ejection Fraction and Severity of Perfusion Defect (일상적인 운동 부하 게이트 심근 관류 SPECT에서 $^{99m}Tc-sestamibi$ 폐섭취 : 좌심실 구혈률과 관류 결손 정도와의 비교)

  • Jeong, Shin-Young;Lee, Jae-Tae;Bae, Jin-Ho;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.83-93
    • /
    • 2003
  • Background: Lung-to-heart uptake ratio (LHR) in $^{201}Tl-chloride$ myocardial perfusion scan is believed to be a reliable marker for left ventricular (LV) dysfunction, but the clinical value of LHR is controversial for $^{99m}Tc-MIBI$ imaging. Furthermore, most of results suggesting lung uptake of $^{99m}Tc-MIBI$ as a potential marker for LV dysfunction used immediate post-stress images, instead of routine images acquired 1 hour after tracer injection. The goal of our study was to investigate whether LHR evaluated with routine gated $^{99m}Tc-MIBI$ imaging can reflect the degree of perfusion defect or left ventricular performance. Subjects and Methods: 241 patients underwent exercise $^{99m}Tc-MIBI$ myocardial SPECT were classified into normal myocardial perfusion (NP, n=135) and abnormal myocardial perfusion (AP, n=106) group according to the presence of perfusion defect. LHR was calculated from anterior projection image taken at 1-hour after injection. Two legions of interest (ROIs) were placed on left lung above LV and on myocardium showing the highest radioactivity. Subjects were classified by left ventricular ejection fraction (LVEF), as Gr-I: >50%, Gr-II: 36-50%, Gr-III: <36% and by summed stress score (SSS), as Gr-A: <4, Gr-B: 4-8, Gr-C: 9-13, Gr-D: >13, LHR was compared among these groups. Results: In NP group(n=135), LHR, were higher in men than women ($men:\;0.311{\pm}0.03,\;women:\;0.296{\pm}0.03,\;p<0.05$). Significant difference, in LHR were found between NP and AP groups both for men and women ($men:\;0.311{\pm}0.03\;vs\;.\;0.331{\pm}0.06,\;women:\;0.296{\pm}0.03\;vs.\;0.321{\pm}0.07.\;p<0.05$). There were weak negative correlation between LHR and LVEF (r=-0.342, p<0.05) and weak positive correlation between LHR and SSS (r=0.478, p<0.05) in men, but not in women (LVEF: r=-0.279, p=0.100, SSS: r=0.276, p=0.103). Increased LHR was defined when for more than mean + 2SD value ($men{\geq}0.38,\;women{\geq}0.37$) of the LHR of the subject with normal perfusion. Increased LHR were observed more frequently in subjects with lower LVEF (Gr-I: 11.1%, Gr-II: 27.0%, Gr-III: 35.4%, p<0.05) and higher SSS(Gr-A: 14.0%, Gr-B: 5.7%, Gr-C: 18.2%, Gr-D: 40.7%, p<0.05). Conclusions: LHRs obtained from routine $^{99m}Tc-MIBI$ gated SPECT images were weakly correlated with LVEF and perfusion defect. Although significant overlaps were observed between normal and abnormal perfusion group, LHRs could be used as an indirect marker of severe perfusion defect or reduced left ventricular function.

Transient Prolonged Stunning by Dipyridamole Stress Proved by Post-stress(1 hour) and 24 hour Tc-99m-MIBI Gated SPECT (반복 게이트 심근 Tc-99m-MIBI SPECT로 확인한 디피리다몰 부하에 의한 일과성 심근기절현상)

  • Lee, Dong-Soo;Yoon, Seok-Nam;Lee, Won-Woo;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.57-66
    • /
    • 1997
  • We performed 1st day Tc-99m-sestamibi gated SPECT with dipyridamole/rest T1-201 SPECT and 2nd day 24 hour delay T1-201 SPECT/rest Tc-99m-sestamibi gated SPECT in 27 patients with coronary artery disease(24) or having chest pain(3). Stress and rest Tc-99m-sestamibi gated SPECT was acquired at 60min post-injection. A 4-point scoring system(0 to 3 for normal to absent tracer uptake) for 17 segments was used. Wall motion was scored on another 4 point scale(0 to 3 for normal to dyskinesia) in the 1st day post-stress gated and the 2nd day rest gated SPECT. Post-stress gated SPECT showed wall motion abnormality in 94 segments(20%). Fifty-five segments among these 94 showed the same wall motion between post-stress and rest gated SPECT: i.e. 1-1 23 segments, 2-2: 29 segments, 3-3: 3 segments. Remaining 39 segments(41.5%) showed different wall motion between post- stress and rest Tc-99m-sestamibi gated SPECT. Twenty one segments with wall motion abnormality had normal perfusion(rest : 15 segments, 24 hour delay: 6 segments) at either rest or 24 hour delay. Fifteen among these 21 segments showed persistent post-stress and the 2nd day rest wall motion abnormality(persistent stunning). However, in 6 segments with pro-longed (1 hour after stress) stunning, abnormal wall motion did improve in the 2nd day rest Tc-99m-sestamibi gated SPECT(transient prolonged stunning). These 6 segments had normal perfusion at rest(n=4) or at 24 hour delay(n=2). Post stress wall motions showed significantly higher scores in persistent stunning than in prolonged transient stunning(P value<0.05). It was concluded that we could find stunned myocardium with gated Tc-99m-sestamibi SPECT at either post-stress or rest and that some myocardial walls of post-stress 1 hour gated SPECT did not show truly rest wall motion. So, we should be cautious if we use post-stress Tc-99m-sestamibi wall motion to assess rest wall motion.

  • PDF

The Usefulness of Myocardial SPECT for the Preoperative Cardiac Risk Evaluation in Noncardiac Surgery (비심장 수술 환자에서 수술 전후 심장사건의 위험도 평가를 위한 심근관류 SPECT의 유용성)

  • Lim, Seok-Tae;Lee, Dong-Soo;Kang, Won-Jun;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.273-281
    • /
    • 1999
  • Purpose: We investigated whether myocardial SPECT had additional usefulness to clinical, functional or surgical indices for the preoperative evaluation of cardiac risks in noncardiac surgery. Materials and Methods: 118 patients (M: F=66: 52, $62.7{\pm}10.5$ years) were studied retrospectively. Eighteen underwent vascular surgeries and 100 nonvascular surgeries. Rest T1-20l/ stress Tc-99m-MIBI SPECT was performed before operation and cardiac events (hard event: cardiac death and myocardial infarction; soft event: ischemic ECG change, congestive heart failure and unstable angina) were surveyed through perioperative periods ($14.6{\pm}5.6$ days). Clinical risk indices, functional capacity, surgery procedures and SPECT findings were tested for their predictive values of perioperative cardiac events. Results: Perioperative cardiac events occurred in 25 patients (3 hard events and 22 soft events). Clinical risk indices, surgical procedure risks and SPECT findings but functional capacity were predictive of cardiac events. Reversible perfusion decrease was a better predictor than persistent decrease, Multivariate analysis sorted out surgical procedure risk (p=0.0018) and SPECT findings (p=0.0001) as significant risk factors. SPECT could re-stratify perioperative cardiac risks in patients ranked with surgical procedures. Conclusion : We conclude that myocardial SPECT provides additional predictive value to surgical type risks as well as clinical indexes or functional capacity for the prediction of preoperative cardiac events in noncardiac surgery.

  • PDF

A study of 99mTc-sestamibi labeling condition using radio-chromatography

  • Moon, Sung-Hyun;Lee, Yun-Sang;Lee, Dong Soo;Chung, June-Key;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.38-43
    • /
    • 2017
  • Tc-99m labeled sestamibi ($^{99m}Tc$-MIBI) is one of most widely used radiopharmaceuticals for myocardial SPECT imaging. Radiolabeling of $^{99m}Tc$-MIBI is recommended by heating in $100^{\circ}C$ water bath for 15 min. However, the water bath might be a source of contamination. Thus, if radiolabeling of $^{99m}Tc$-sestamibi can be performed at room temperature, then it would be more convenient to use in clinical application. In this study, we performed the radiolabeling of $^{99m}Tc$-MIBI in different temperature conditions or using different instruments to find out the efficient labeling condition. We studied the $^{99m}Tc$-MIBI labeling at room temperature or $100^{\circ}C$ heating block, and checked the labelling yields every 1 min for 10 min using radio-TLC with 2 different eluents-saline and acetone. From the experiment, we confirmed that the $^{99m}Tc$-MIBI can be labeled over 90% yield but not completed at room temperature. However, the $^{99m}Tc$-MIBI labeling was completed when it was performed in the $100^{\circ}C$ heating block. Finally, we proved that heating is essential for complete $^{99m}Tc$-MIBI labelling, furthermore using heating block is also possible instead of water bath.