• Title/Summary/Keyword: $^{99m}$Tc

Search Result 1,347, Processing Time 0.041 seconds

A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging (핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰)

  • Ji-Hyeon Kim;Jooyoung Lee;Hoon-Hee Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.57-69
    • /
    • 2024
  • Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source. Materials and Methods: A 99mTcO4- source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%). Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume. Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.

Prediction of Post-operative Cardiopulmonary Function By Perfusion Scan (폐관류 검사를 이용한 폐절제술 후 심폐운동기능의 예측)

  • Ryu, Jeong-Seon;Lee, Ji-Young;Seo, Dong-Bum;Cho, Jae-Hwa;Lee, Hong-Lyeol;Yoon, Yong-Han;Kim, Kwang-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.401-408
    • /
    • 2001
  • Background : Perfusion scans are accurate predictors of postoperative lung function. There are few previous studies aimed at predicting the postoperative exercise capacity using the perfusion scanning and those that did reported contradictory results. Method : We prospectively studied the preoperative spirometric, exercise tests and perfusion scans from in 49 consecutive patients who were admitted to Inha University Hospital with surgically resectable lung cancer from Jan. 1998 to Jun. 1999 29 patients who had any condition affecting the lung function and exercise capacity, or refused a surgical resection or a follow-up study were excluded. Spirometric and exercise tests were performed 6 months after operation in 20 patients. Results : The predicted postoperative $FEV_1$, FVC and TLC correlated well with the following corresponding postoperative values : $r_s$ and p value, 0.809 and 0.000 for the $FEV_1$ 0.895 and 0.000 for the FVC ; 0.741 and 0.006 for the TLC, respectively. The measured postoperative exercise values were slightly higher than the postoperative exercise values predicted, $VO_{2max}$ and $Wr_{max}$, were as 112% of $VO_{2max}$ predicted and 119% of $WR_{max}$ predicted. The change in $FEV_1$, FVC and TLC had a weak correlation with the change in $VO_{2max}$ and $WR_{max}$. Conclusion : The perfusion scan was a useful tool for predicting the postoperative exercise capacity. However, they had a tendency to underestimate the exercise capacity, especially in the patients who had a pneumonectomy. A weak correlation between the change in lung function and exercise capacity was observed.

  • PDF

Impact and Prevalence of Renin-angiotensin System Gene Polymorphism of Renal Anomalies in Turner Syndrome (터너 증후군에서 신기형의 발생에 미치는 레닌-안지오텐신계 유전자 다형성의 영향)

  • Park Ji-Kyoung;Chung Young-Hee;Lee Jeong-Nyeo;Chung Woo-Yeong
    • Childhood Kidney Diseases
    • /
    • v.7 no.1
    • /
    • pp.52-59
    • /
    • 2003
  • Purpose : The renin-angiotensin system(RAS) plays an important role in renal growth and development. We have studied the prevalence of renal anomalies and documented the association between karyotype and renal anomalies using IVP and ultrasonography. Furthermore, to investigate the impact of RAS gene polymorphism on renal anomaly in Turner syndrome, we examined the ACE I/D genotype, angiotensinogen(AGT) gene M235T, angiotensin receptor type 1(ATR) gene A1166C. Methods : Cytogenetic analysis was performed in 33 Turner syndrome patients on peripheral blood lymphocytes. Ultrasonography(US) of the kidneys and collecting system and intravenous pyelography(IVP) were perfomed in all patients. Nuclear scintigraphy{Tc 99m dimercaptosuccinic acid(DMSA) scan} was also performed for the definite renal diagnosis if indicated. And, ACE I/D genotype, angiotensinogen(AGT) gene M235T, angiotensin receptor type 1(ATR) gene A1166C were examined by PCR amplification of genomic DNA samples. Results : The prevalence of renal anolmalies in Turner syndrome was 36.4%(12/33). The Karyotype 45, X was observed in 18 of the 33 girls(54.5%), of whom 8(44.4%) had renal anomalies. Mosaic karyotypes were observed in 11(33.3%) and four(12.2%) had a non-mosaic structural aberration of the X chromosome. In this group 4(25.7%) had renal anomalies. More renal anomalies were associated with the 45, X karyotype than those with mosaic/structural abnormalities of X chromosome, but the difference was not statistically significant(P>0.05). And, there was no significant differences in the RAS gene polymorphism and allele frequencies between renal anomaly group and normal group in Turner syndrome. Conclusion : The prevalence of renal anolmalies in Turner syndrome was 36.4%. There is no significant differences in the RAS gene polymorphism and allele frequencies between the renal anomaly group and the normal group in Turner syndrome.

  • PDF

Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom (Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가)

  • An, Byung Ho;Yeon, Joon Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 2015
  • Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. $^{99m}Tc-HDP$ source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

  • PDF

Applications of "High Definition Digital Climate Maps" in Restructuring of Korean Agriculture (한국농업의 구조조정과 전자기후도의 역할)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.1
    • /
    • pp.1-16
    • /
    • 2007
  • The use of information on natural resources is indispensable to most agricultural activities to avoid disasters, to improve input efficiency, and to increase lam income. Most information is prepared and managed at a spatial scale called the "Hydrologic Unit" (HU), which means watershed or small river basin, because virtually every environmental problem can be handled best within a single HU. South Korea consists of 840 such watersheds and, while other watershed-specific information is routinely managed by government organizations, there are none responsible for agricultural weather and climate. A joint research team of Kyung Hee University and the Agriculture, forestry and Fisheries Information Service has begun a 4-year project funded by the Ministry of Agriculture and forestry to establish a watershed-specific agricultural weather information service based on "high definition" digital climate maps (HD-DCMs) utilizing the state of the art geospatial climatological technology. For example, a daily minimum temperature model simulating the thermodynamic nature of cold air with the aid of raster GIS and microwave temperature profiling will quantify effects of cold air drainage on local temperature. By using these techniques and 30-year (1971-2000) synoptic observations, gridded climate data including temperature, solar irradiance, and precipitation will be prepared for each watershed at a 30m spacing. Together with the climatological normals, there will be 3-hourly near-real time meterological mapping using the Korea Meteorological Administration's digital forecasting products which are prepared at a 5 km by 5 km resolution. Resulting HD-DCM database and operational technology will be transferred to local governments, and they will be responsible for routine operations and applications in their region. This paper describes the project in detail and demonstrates some of the interim results.

Comparison Study between Myocardial Velocity obtained from Gated Myocardial SPECT and Myocardial Functional indices with a Focus on Myocardial Perfusion (게이트 심근 관류 SPECT에서 구한 심근 속도와 심근 관류를 중심으로 한 심근 기능 지표와의 비교연구)

  • Ha, Jung-Min;Jeong, Shin-Young;Bom, Hee-Seung;Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.386-394
    • /
    • 2009
  • Purpose: We aimed to assess the myocardial velocity on gated myocardial perfusion SPECT (gated MPS), to compare myocardial velocity between patients without coronary artery disease (CAD) and CAD patients and to assess the correlation of myocardial velocity and perfusion and wall thickening on CAD group. Materials and Methods: Seventeen patients without CAD (M:F=9:8, mean age $61.8{\pm}11.1$ yrs: group A) and thirty-nine patients with CAD (M:F=18:21, mean age $66.9{\pm}8.1$ yrs : group B) had undergone one-day adenosine stress gated MPS. In twenty segment model, 12 segments (except apical and basal segments) of each patient were included. We obtained systolic and diastolic gate ratio in left ventricular volume curve by eight frames per cardiac cycle on gated MPS. Using the systolic and diastolic gate ratio and R-R time of each patient, we obtained systolic and diastolic time ratio. The myocardial velocity was defined as wall thickening over systolic or diastolic time. Results: We presented normal range of myocardial velocities according segments and territories of coronary artery. The myocardial velocity of group B was significantly lower than group A (p=0.00). There was no significant difference between the myocardial velocity of group B with preserved EF and group A. The stress systolic velocity significantly correlated with regional myocardial perfusion in group B with preserved EF (p=0.00) as well as decreased EF (p=0.01). In group B, stress perfusion of segments which had decreased wall thickening and decreased myocardial velocity was significantly lower than segments which had decreased wall thickening and preserved myocardial velocity (p=0.01). Conclusion: The new functional index of velocity will be used as an useful of gated MPS.

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

Usefulness of Blood Pool Half Body in Three Phase Bone Scan in Patients with R/O Reflex Symphathetic Dystrophy Syndrome (반사성교감신경 이영양증후군 환자의 삼상 골 스캔 시 Half Body 혈액 풀 영상의 적용)

  • Lee, Moo-Seok;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.105-110
    • /
    • 2010
  • Purpose: Three phase bone scan was considered sensitive in Patients with Reflex Symphathetic Dystrophy Syndrome (RSDS). Generally, three phase bone scan in the RSDS patients shows increased uptake of one side extremity joint. But three phase bone scan has been performed with flow, blood pool and delayed scan. We performed blood pool half body scan in order to investigate its usefulness. Materials and Methods: From October 2007 to September 2009, three phase bone scan (flow, blood pool, half body blood pool, delayed) was performed after injection of 750 MBq of $^{99m}Tc$-DPD in diagnosed patients with RSDS (M:F=8:7, R:L=9:6). For quantitative analysis, we obtained the count ratios of bilateral hands by drawing a region of interest (ROI) in the three phase images and compared with the count ratios of shoulders in half body blood pool and delayed images. Results: In flow images, right/left ratios were $1.09{\pm}0.53$. In blood pool images, right/left ratios were $1.13{\pm}0.47$ (hand), $1.08{\pm}0.26$ (shoulder). In delayed images, right/left ratios were $1.24{\pm}0.75$ (hand), $1.11{\pm}0.31$ (shoulder). As a result, Log of right/left counts of the others and that of shoulder blood pool image were correlated well with statistical significance (Spearman's R, p<0.005 SPSS for windows ver.12.0). Conclusion: Half body blood pool scan may be helpful in the diagnosis of patients with RSDS. Moreover, Half body blood pool scan reduced false negative and false positive rates. In order to improve agreement on interpretation of RSDS, Blood pool half body scan should be established as common criteria.

  • PDF

Development of Geometric Calibration Method for Triple Head Pinhole SPECT System (삼중헤드 SPECT에서 기하학적 보정 기법의 개발)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Won-Woo;Park, So-Yeon;Son, Ji-Yeon;Kim, Yu-Kyeong;Kim, Sang-Eun;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Purpose: Micro-pinhole SPECT system with conventional multiple-head gamma cameras has the advantage of high magnification factor for imaging of rodents. However, several geometric factors should be calibrated to obtain the SPECT image with good image quality. We developed a simplified geometric calibration method for rotating triple-head pinhole SPECT system and assessed the effects of the calibration using several phantom and rodent imaging studies. Materials and Methods: Trionix Triad XLT9 triple-head SPECT scanner with 1.0 mm pinhole apertures were used for the experiments. Approximately centered point source was scanned to track the angle-dependent positioning errors. The centroid of point source was determined by the center of mass calculation. Axially departed two point sources were scanned to calibrate radius of rotation from pinhole to center of rotation. To verify the improvements by the geometric calibration, we compared the spatial resolution of the reconstructed image of Tc-99m point source with and without the calibration. SPECT image of micro performance phantom with hot rod inserts was acquired and several animal imaging studies were performed. Results: Exact sphere shape of the point source was obtained by applying the calibration and axial resolution was improved. Lesion detectibility and image quality was also much improved by the calibration in the phantom and animal studies. Conclusion: Serious degradation of micro-pinhole SPECT images due to the geometric errors could be corrected using a simplified calibration method using only one or two point sources.