• Title/Summary/Keyword: $^{60}Co$ 감마선

Search Result 195, Processing Time 0.029 seconds

The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구)

  • Ahn, Ki-Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.183-188
    • /
    • 2017
  • In recent years, the automatic remote control controller of the gamma ray irradiator malfunctions, and radiation workers are continuously exposed to radiation exposure accidents. In the non-destructive testing field, much time and resources are invested in establishing a radioactive source monitoring system in order to prevent potential incidents of radiation. In this study, the gamma-ray response properties of the lead monoxide-based radiation detector were estimated through monte carlo simulation as a previous study for the development of a radioactive source location monitoring system that can be applied universally to various non-destructive testing equipment. As a result of the study, the optimized thickness of the radiation detector varies according to the gamma-ray energy emitted from the radioactive source, and the optimized thickness gradually increases with increasing energy. In conclusion, the optimized thickness of the lead monoxide-based radiation detector was $200{\mu}m$ for the Ir-192, $150{\mu}m$ for the Se-75 and $300{\mu}m$ for the Co-60. Based on these results, the appropriate thickness of lead monoxide-based radiation detector considering secondary-electron equilibrium was evaluated to be $300{\mu}m$ for general application. These results can be used as a basic data for determining the appropriate thickness required in the radiation detector when developing a radiation source location monitoring system for universal application to various non-destructive testing equipment in the future.

Induction of Petal Color Mutants through Gamma Ray Irradiation in Rooted Cuttings of Rose (장미 삽목묘의 감마선 처리에 의한 화색 돌연변이체 유기)

  • Koh, Gab-Cheon;Kim, Min-Za;Kang, Si-Yong
    • Horticultural Science & Technology
    • /
    • v.28 no.5
    • /
    • pp.796-801
    • /
    • 2010
  • This study was carried out to establish a system for mutation breeding by irradiation of gamma-ray in $Rosa$ $hybrida$ Hort. The rooted cuttings of two roses, 'Spidella' and 'Cabernet' were irradiated with different gamma-ray doses (0, 30, 50, 70, 90, 110, 130, 150 and 170 Gy) from a $^{60}Co$ source to reveal an optimal dose for induction of mutants. The irradiated plants were planted in a greenhouse, and investigated on the appearance of petal color mutants and shoot growth by gamma ray dose. The 50% lethal doses ($LD_{50}$) of plant were 110 Gy for 'Spidella' and 150 Gy for 'Cabernet', respectively. The 50% decrease dose of shoot length was observed at 70-90 Gy dose for 'Spidella', and 110 Gy dose for 'Cabernet'. Solid, chimeric and mosaic petal mutants with various colors were induced from pink petal of 'Spidella' and red petal of 'Cabernet' when 30-170 Gy dose was irradiated. The mutants obtained from 'Spidella' had white, ivory, pinky ivory, light pink and deep pink petal colors. The mutants obtained from 'Cabernet' had pink, deep pink, purple red (magenta), orange red and purple petal colors. It was suitable to irradiate 70-90 Gy dose for 'Spidella' and 90-110 Gy dose for 'Cabernet' for the induction of various mutants considering plant survival rate, shoot growth and mutant occurrence rate.

Radiation Effects of Fiber Bragg Gratings on the High Temperature Annealing Condition (광섬유 브래그 격자의 고온 어닐링 조건에 따른 방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Im, Don-Sun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.785-787
    • /
    • 2016
  • In this study, we studied the gamma-radiation effect of fiber Bragg gratings on the high temperature annealing condition. The fiber Bragg gratings were exposed to gamma-radiation up to a dose of 30.8 kGy at the dose rate of 115 Gy/min. According to the experimental data and analysis results, the gratings that were stabilized at different temperatures have clearly shown that exposure to higher temperatures increases their radiation sensitivity.

  • PDF

Comparison of the Correction Methods for Gamma Ray Attenuation in the Radioactive Waste Drum Assay (방사성폐기물드럼 핵종분석에서 감마선 감쇠보정 방법들의 비교 평가)

  • Ji Young-Yong;Ryu Young-Gerl;Kwak Kyoung-Kil;Kang Duck-Won;Kim Ki-Hong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.275-284
    • /
    • 2006
  • In the measurement of gamma rays emitted from the nuclide in the radioactive waste drum, to analyze the nuclide concentration accurately, it is necessary to use the proper calibration standards and to correct for the attenuation of the gamma rays. Two drums having a different density were used to analyze the nuclide concentration inside the drum in this study. After carrying out the system calibration, we measured the gamma rays emitted from the standard source inside the model drum with changing the distance between the drum and the detector. The measured values were corrected with the three kinds of gamma attenuation correction methode, as a results, the error was less than 10 % in the low density drum and less than 25 % in the high density drum. The measured activity in the short distance was more accruable than in the long distance. The transmission correction for the mass attenuation showed good results(very Low error) compared to the mean density and the differential peak correction method.

  • PDF

Active Transport Characteristics of Anions through a Cell Membrane Model which Irradiated by γ-ray (감마선이 조사된 세포막모델을 통한 음이온의 능동 전달 특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.187-195
    • /
    • 2015
  • The active transport characteristics of anions of cell membrane model which irradiated by $^{60}Co\;{\gamma}-ray$ was investigated. The cell membrane model used in this experiment was a sulfonated copolymerized membrane of poly(1-methyl-4-vinylpyridiniumiodide-co-divinylbenzene : MeVP-DVBI). First, the initial flux of $OH^-$ and $Cl^-$, $Na^+$ of membrane which was not irradiated was decreased with increase of thickness of membrane $80-200{\mu}m$, increased with increase of NaOH concentration 0-0.5mol/L and MeVP-DVBI concentration 20-80% was increased with initial flux of $OH^-$ and $Cl^-$, decreased with initial flux of $Na^+$. Second, the initial flux of membrane which was irradiated was less than that. And the driving force of pH of irradiated membrane was significantly increased more than membrane which was not irradiated. The initial flux of the $OH^-$ ion was decreased with increase of $H^+$ ion concentration. As selective transport of $OH^-$ and $Cl^-$ of cell membrane model were abnormal, cell damages were appeared at cell.

Effect of Additives on Gamma Radiolysis of Methanol (메탄올의 감마선 분해에 대한 첨가물의 영향)

  • Choi, Sang-Up
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.3
    • /
    • pp.237-242
    • /
    • 1970
  • Effect of Added 1-hexene on the yield of hydrogen produced from Co-60 gamma radiolysis of methanol was investigated at room temperature. The results indicated that the yield of hydrogen decreased rapidly with increasing 1-hexene concentrations. Effect of added methyl borate on the radiolysis of methanol was also studied in the presence of oxygen. The results revealved that methyl borate acted as a less effective scavenger than oxygen towards the precursors of the radiolysis products. Experimental data previously obtained on the systems with oxygen added were treated more quantitatively to re-examine mechanism of the radiolysis of methanol in detail.

  • PDF

Radiation-Induced Graft Copolymerization of Hydrophilic Monomers to Polyester

  • Lee, Chong-Kwang;Park, Jae-Ho
    • Nuclear Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.90-101
    • /
    • 1972
  • Radiation grafting of acrylic acid to Polyester fabric has been studied by an impregnation method to render its surface more hydrophilic. Impregnated fabric was irradiated under nitrogen with gamma-ray from Co-60. The homopolymer formed usually could be extracted with water at 10$0^{\circ}C$. Graft-fabric exhibited a good acceptability to acid, basic or disperse dyes in conventional aqueous dye bath at moderate temperature.

  • PDF

Evaluation of Dosimetric Characteristics of Reproducibility, Linearity and Dose Dependence of Optically Stimulated Luminescence Dosimeters in Co-60 Gamma-rays (Co-60 감마선을 이용한 광자극발광선량계의 재현성, 선형성, 선량의존성에 대한 특성평가)

  • Han, Su Chul;Choi, Sang Hyoun;Park, Seungwoo;Kim, Chul Hang;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Chan Hyeong;Ji, Young Hoon;Yi, Chul Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • We aimed to evaluate the dosimetric characteristics of reproducibility, linearity and dose dependence of optical stimulated luminance dosimeter (OSLD) in the Co-60 Gamma-rays and to analyze with a precedent study in field of the diagnostic radiography and radiotherapy. The reproducibility was 0.76% of the coefficient of variation, the homogeneity was within 1.5% of the coefficient of variation and OSLD had supra-linear response more than 3 Gy. So the correlation between dose and count was fitted by quadratic function. The count depletion by repeated reading was 0.04% per reading regardless of the irradiated dose. And the half time of decay curve according to the irradiated dose was 0.68 min. with 1 Gy, 1.04 min. with 5 Gy, and 1.10 min. with 10 Gy, respectively. In case of annealing for 30 min, the removal rate was 88% with 1 Gy, 90% with 5 Gy, and 92% with 10 Gy, respectively and 99% in case of annealing time for 4 hour. It is feasible to use OSLDs for dose evaluation in Co-60 Gamma-rays when considering the uncertainty on the procedure according to the irradiated dose.

Effect of High Dose ${\gamma}-irradiation$ on the Physicochemical Properties of Shell Eggs during Storage (고선량 감마선 조사가 신선란의 저장 중 이화학적 특성에 미치는 영향)

  • Moon, Sun-Ae;Song, Kyung-Bin
    • Applied Biological Chemistry
    • /
    • v.43 no.4
    • /
    • pp.260-265
    • /
    • 2000
  • To determine the quality change of the irradiated eggs during storage, fresh shell eggs were irradiated using $^{60}Co$ at 0, 1, 5, 10, 30 kGy and stored for 30 days. The york index, color, pH, viscosity, egg weight, and SDS-PAGE profile of the irradiated eggs were examined. During storage, york index values of the irradiated eggs and the control were decreased and the increase of dose decreased yolk index. However, the yolk index values were increased temporarily at 10 kGy and 30 kGy. The yolk color had a bright yellow with increases in dose level and there was no significant change during storage. The albumen viscosities were decreased with increases in dosage and were decreased during storage. Also, the albumen pH values of the irradiated eggs were higher than that of the control and were increased during storage. The weight losses of eggs were increased during storage and there were no significant changes by dose level. SDS-PAGE profile of the egg white proteins of the shell eggs showed the change in molecular weight distribution and had aggregation pattern as well as degradation. CD and fluorescence spectroscopy study showed changes in the secondary and tertiary structure of egg white proteins by ${\gamma}-irradiation$. Therefore, this study clearly indicates that irradiation dose of eggs should be appropriate to prevent the loss of egg qualities.

  • PDF

The Calculation of Response Matrix of 2-Dimensional Radiation Monitoring System Using EGS4 Simulation (EGS4 simulation을 이용한 2차원 방사선준위 분포측정 시스템의 Response Matrix 계산)

  • Kim, S.H.;Han, S.H.;Kang, H.D.;Kim, J.C.;Park, I.K.;Choi, Y.S.;Lee, Y.B.;Lee, J.M.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.127-133
    • /
    • 1997
  • In this study an EGS4 simulation code was used to calculate real energy spectrum from measured ${\gamma}$-ray energy spectrum obtained using 2-dimensional radiation monitoring system. As a result, the $39{\times}39$ response matrix was calculated the energy range of 0.1 to 2 MeV which energy interval of 50 keV The real energy spectrum for Co-60 radioisotope was calculated using inverse of response matrix. It was confirmed that the calculated response matrix was useful to the analysis of the measured energy spectrum for the radiation monitoring system.

  • PDF