• Title/Summary/Keyword: $^{60}Co$ 감마선

Search Result 195, Processing Time 0.031 seconds

Combined Effect of Heat Treatment and Gamma Irradiation on the Shelf-Stability and Quality of Packaged Kimchi during Accelerated Storage Condition (가열 및 감마선 조사 병용처리가 가속저장 포장 김치의 저장안정성 및 품질에 미치는 영향)

  • Kim, Mi-Jung;Park, Jin-Gyu;Kim, Jae-Hun;Park, Jae-Nam;Lee, Hyun-Joo;Kim, Wang-Geun;Lee, Ju-Woon;Byun, Myung-Woo
    • Food Science and Preservation
    • /
    • v.13 no.5
    • /
    • pp.531-537
    • /
    • 2006
  • This study was conducted to evaluate the combined effect of heating and gamma irradiation on the shelf-stability and quality of kimchi during storage at $35^{\circ}C$. The optimum condition for heat treatment of kimchi was considered at $60^{\circ}C$ for 30 min. Irradiation after kent treatment was effective to inhibit the growth of microorganisms and prevent the quality change of kimchi during storage. In particular, microorganisms of kimchi co-treated with heat and 20 kGy-irradiation were not detected and sensory scores of that were the highest after storage at $35^{\circ}C$ for 14 days. Therefore, combination treatment of heat and irradiation was considered as the effective method to improve the shelf-stability of kimchi in the accelerated condition.

Shielding Effectiveness of Magnetite Heavy Concrete on Cobalt-60 Gamma-rays

  • Lim, Yong-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.65-75
    • /
    • 1971
  • The gamma-ray shielding effects of magnetite concretes have been measured using a broad beam Co-60 gamma-ray source. Mathematical formulae for a trans-mission ratio-to-shield thickness relation were derived from the attenuation curve obtained experimentally and are I (x) = I (ο) exp(-$\mu$X) exp(1.03$\times$10$^{-1}$ X-3.38$\times$10$^{-3}$ X$^2$+5.29$\times$10$^{-5}$ X$^3$) when X< 20 cm, I (x) =I (ο) exp(-$\mu$X) exp(4.66$\times$10$^{-2}$ X+2.12$\times$10$^{-1}$ ) when X>20 cm. Here I (x) is radiation intensity after passing through a thickness X of absorber, I(o) is the initial radiation intensity, $\mu$ is the linear attenuation coefficient of magnetite concrete and is given by (0.0532$\rho$+ 0.0083)$^{4)}$ $cm^{-1}$ / in accordance with an earlier study, and X is the thickness of absorber. In addition, a model shield which is a rectangular magnetite concrete box with walls of 8cm thickness walls and internal demensions of 40$\times$40$\times$40 cm was constructed and its shielding effect has been measured. The emergent radiation flux appears to be greater with this configuration than with a slab shield of equal thickness.

  • PDF

Characteristics of Antifungal Bacterium, Bacillus subtilis YS1 and It′s Mutant Induced by Gamma Radiation (온천수로부터 분리한 항진균세균의 특성 및 감마선$(Co^{60})$ 조사를 이용한 돌연변이체 유기)

  • 이영근;김재성;송인근;정혜영;장화형
    • Korean Journal of Microbiology
    • /
    • v.37 no.4
    • /
    • pp.305-311
    • /
    • 2001
  • Antifungal bacterium, Bacillus subtilis YS1 was isolated from Yusong hot spring showed broad antifungal spectrum against 12 kinds of plant pathogenic fungi and Candida albicans, animal pathogen. From the gamma($Co^{60}$) radiation sensitivity test, $D_10$ value was 2.08 kGy and it survived above 20 kGy of radiation dose. Several mutants were induced by gamma radiation. Among them, YS1-1009 mutant showed resistance against tebuconazole of herbicide, increased activity against Botryoshaeria dothidea and ligninase activity. YS67 mutant was antifungal deficient auxotrophic mutants(trp-pro-or arg-ura-). From this results, it suggested that gamma irradiation could be useful method for mutant induction.

  • PDF

Effects of Low-Dose Gamma Irradiation on Physicochemical Properties and Formation of Resistant Starch of Corn Starch (저선량 감마선 조사가 옥수수 녹말의 이화학 성질 및 저항전분 생성에 미치는 영향)

  • Kim, Sung-Kon;Kim, Jeong-Hee;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.378-384
    • /
    • 2006
  • Intrinsic viscosity of starch irradiated with Co-60 (0.25-9.1 kGy) significantly decreased, and swelling power and solubility measured at $80^{\circ}C$ linearly increased with increasing irradiated dose. Radiation treatment up to 1 kGy increased amylose content of starch. Water-binding capacity increased rapidly up to 3 kGy. Peak viscosity of irradiated starches by Rapid visco Analyser and Visco/amylo/Graph indicated that the decrease in peak viscosity was dose-dependent. Gamma irradiation showed no effect on endothermic temperatures of irradiated starches, but decreased endothermic enthalpy with increasing dose level. Viscosity of starch autoclaved at $120^{\circ}C$ and air-dried significantly decreased with increasing irradiation dose. Resistant starch content slightly decreased upon irradiation.

Radiation Effects on Fiber Bragg Grating Sensors Written in UV KrF Laser Process Condition (UV KrF 레이저 공정조건에 따른 FBG 센서의 방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.161-166
    • /
    • 2016
  • We studied the effect of $Co^{60}$ gamma-radiation on the FBGs by a variation of grating the fabrication parameters. The FBGs were fabricated in a different UV KrF laser intensity using the same boron co-doped photo-sensitive fiber and exposed to gamma-radiation up to a dose of 33.8 kGy. According to the experimental data and analysis results, We confirmed that the laser intensity for grating inscription has a highly effect on the radiation sensitivity of the FBGs and the radiation-induced Bragg wavelength shift by the change of laser process condition showed a difference more than about 30 %.

The Study of Radiation Sensitivity on Fiber Bragg Grating Written in Photo-sensitive Optical Fibers (광민감 광섬유로 제작한 광섬유 브래그 격자 센서의 방사선 민감도에 대한 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.2023-2028
    • /
    • 2014
  • In this study, we studied the effect of $Co^{60}$ gamma-radiation on the FBGs written in photo-sensitive and commercial Ge-doped single-mode optical fibers. The FBGs were exposed to gamma-radiation up to a dose of 17.8 kGy at the dose rate of 300 Gy/min. According to the experimental data and analysis results, the lowest Bragg wavelength shift (18 pm) was obtained by a grating written in photosensitive fiber without $H_2$-loading. Also, we confirmed that the H2 loading process has considerably more influence on the Bragg wavelength shift change under gamma radiation than $GeO_2$ contents in the fiber core.

Biological Activities of Extracts from Gamma-irradiated Aralia elata Cortex (감마선 조사한 총목피(Aralia elata Cortex) 추출물의 생리활성)

  • Park, Hye-Jin;Lee, Eun-Ho;Kim, Myung-Uk;Lee, Seon-Ho;An, Dong-Hyun;An, Bong-Jeun;Kwon, Joong-Ho;Cho, Young-Je
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.8
    • /
    • pp.1236-1247
    • /
    • 2014
  • Gamma irradiated-treatment of natural medicinal plants can be used to improve extraction transference number and for qualitative improvement of color when applied to functional material exploration. This study investigated the biological activities of Aralia elata cortex extracts upon gamma irradiation. In addition, different physical techniques [photostimulated luminescence (PSL) and thermoluminescence (TL)] were used for irradiation identification of Aralia elata cortex. In PSL analysis, non-irradiated (0 kGy) sample showed a negative result of 400 photon counts (PCs), whereas irradiated (5, 10, and 30 kGy) samples showed positive results of 90,100.00, 312,614.33, and 321,661.67 PCs, respectively. In the TL method, growth curve showed very unusual behaviors around $200^{\circ}C$ upon natural-irradiation of the non-irradiated (0 kGy) sample and around $150{\sim}250^{\circ}C$ for the irradiated (5, 10, and 30 kGy) samples. The TL ratio was 0.1 in non-irradiated samples at 0.011, whereas the values of irradiated samples (5, 10, and 30 kGy) were 0.1 at 1.105, 1.009, and 2.206, respectively. For phenolics of gamma-irradiated Aralia elata cortex, water and 50% ethanol extracts had the highest amounts, $17.30{\pm}0.40mg/g$ and $18.87{\pm}0.46mg/g$ at 10 kGy irradiation, respectively. The inhibitory activities of angiotensin-converting enzyme and xanthin oxidase were higher in both irradiated water and 50% ethanol extracts than in non-irradiated ones. For pancreatin ${\alpha}$-amylase and ${\alpha}$-glucosidase inhibitory activities, water and 50% ethanol extracts containing $200{\mu}g/mL$ of phenolics showed high inhibitory activities of 60~100% at all irradiation doses (0~30 kGy). This result confirmed that Aralia elata cortex extracts have greater anti-diabetic effects than acabose as a diabetic remedy. Gamma-irradiated Aralia elata cortex extracts are useful as a functional material with anti-diabetic effects. Thus, Aralia elata cortex extracts can be used as a functional material with various biological activities, and gamma-irradiation can be used to amplify biological activities in plants.

Calculation of Tissue-Air Ratios(TAR) in Irregularly shaped Field for Co-60 Gamma Radiation (CO-60 감마선에 대한 부정형조사면의 조직공중선량비 (TAR) 계산)

  • Ji Young-Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.3 no.1
    • /
    • pp.27-36
    • /
    • 1989
  • In order to calculate the dose on each interest point in five types of irregularly shaped fields used commonly in radiotherapy, the tissue-air ratios (TAR) in these fields for Go-60 gamma radiation were calculated using the newly devised SAR-chart. The TARs calculated from newly method of using the SAR-chart, computer method and approximation method at the interest point were compared to the TARs obtained from measurement. The result are as follows; In case of the interest points on central axis the calculated TARs in irregularly shaped fields by the above mentioned methods were well agreed within the error of $1\%$, whereas for the interest points on off-axis the calculated TARs were resulted in the maximum errors of $2.4\%,\;2.3\%$ and $8.8\%$ respectively. From these results, the accuracy of calculation method of using the SAR-chart was comfirmed.

  • PDF

SIMULATION OF SHIELDING EFFECTS ON THE TOTAL DOSE OBSERVED IN TDE OF KITSAT-1 (KITSAT-1 TDE의 차폐 효과에 의한 총 축적 방사능양 변화에 대한 연구)

  • 김성준;신영훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.71-80
    • /
    • 2001
  • The threshold voltage shift observed in TDE (Total Dose Experiment) on board the KITAT-1 is converted into dose (rad($SiO_2$)) using the result of laboratory calibration with Co-60 gamma ray source in KAERI (Korea Atomic Energy Research Institute). Simulation using the NASA radiation model of geomagnetosphere verifies that the dose difference between RADFET1 and RADFET3 observed on KITSAT-1 comes from the difference in shielding thickness at the position of these RADFETs.

  • PDF

The Experimental Study of the Effective Point of Measurement for Cylindrical Ion Chamber -For Medical Electron Beams- (원통형 전리함의 유효 측정점에 관한 실험적 연구 -의료용 전자선을 중심으로-)

  • 이병용;최은경;장혜숙;홍석민;이명자;전하정
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.155-160
    • /
    • 1991
  • We have studied the effective point of measurement for cylindrical ion chamber in water phantom for medical electron beams. Markus parallel plate chamber water phantom are used for the measurement of depth dose to determine the depth of the effective point of measurement for various energies(for electron 6MeV, 9MeV, 12MeV, 16MeV, and 20MeV; Co-60; for photon 6MV, 15MV). Cylindrical ion chambes(PTW233643 with r=2.75mm, PR-05P with r=2mm, and PM30 wiht r=15mm are used for the measurement of depth dose by same mtethod and the values of d$\_$50/ and R$\_$p/ obtained by three cylindrical chambers were compared with those of a flat chamber. From this we could evaluate the effective measuring points of cylindrical ion chamber. The effective point of measurement was estimated as 0.4~0.6r shifted toward surface from the center of the chamber for electron beam, 0.3~0.7r for $\^$60/Co X-ray.

  • PDF