• Title/Summary/Keyword: $^{252}Cf$ 중성자선원

Search Result 23, Processing Time 0.026 seconds

Radioactive Neutron Source Calibration at the Korea Standards Research Institute (K-SRI 에서의 방사성 중성자 선원교정)

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.67-73
    • /
    • 1985
  • The manganous sulfate bath method for neutron source calibrations at the K-SRI is described together with the measurement of neutron emission rate of a source and the corrections applied for capture by competing nuclei of neutrons, and thermal neutron leakage, neutron absorption in the source itself. The commercially available neutron sources (Am-Be, $^{252}Cf$) for the calibration checks of neutron radiation instruments in the MeV range are considered in this paper.

  • PDF

Evaluation of Neutron Detection Efficiency of the Unified Non-Destructive Assay Using MCNPX Code (MCNPX 코드를 이용한 통합비파괴측정장치의 중성자 검출 효율 평가)

  • Won, Byung-Hee;Seo, Hee;Lee, Seung Kyu;Park, Se Hwan;Kim, Ho Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.172-178
    • /
    • 2013
  • In this study, neutron detection efficiency of the UNDA system, which has been developed for study on nuclear material accountancy in a future pyro-process facility, was evaluated by using the MCNPX code. The detection efficiency was evaluated as a function of (1) positions of $^{252}Cf$ neutron source in the axial and radial directions, and (2) thicknesses and locations of the container filled with the depleted uranium materials for two different designs of the UNDA. In the case of $^{252}Cf$ source positions, detection efficiency was distributed from 6.83% to 13.35%. As $^{252}Cf$ source was positioned at upper part in the axial direction, detection efficiency was decreased after a slight increase. On the other hands, as $^{252}Cf$ source was positioned at outer part in the radial direction, detection efficiency was increased. In the case of container thickness, there was a slight decline when the thickness was increased. As the container was located at upper part, detection efficiency was decreased and as the container was located at outer part, detection efficiency was increased. Detection efficiency was varied from 10.31% to 13.61%. These values were higher than that of $^{252}Cf$ source case. The UNDA with polyethylene cover has about 2% higher detection efficiency than the UNDA without the cover.

Anisotropy and Dose Equivalents Conversion Factors for the Unmoderated $^{252}Cf$ Source (비감속 $^{252}Cf$ 중성자선원에 대한 비등방성교정인자 및 선량당량환산인자)

  • Jeong, Deok-Yeon;Chang, Si-Young;Yoon, Suk-Chul;Kim, Jong-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 1993
  • Form the pure Maxwellian distribution(kT= 1.42MeV), the effects upon calibration factors of encapsulating a $^{252}Cf$ spontaneous fission neutron source were investigated to establish a standard neutron field in the Secondary Standard Dosimetry Laboratory at Korea Atomic Energy Research Institute(KAERI). A Monte Carlo code MCNP was used in simulating the encapsulation SR-Cf-100 and SR-Cf-1273 to be real conditions. The anisotropy(FI) and fluence-to-dose equivalents conversion factors$(H/{\Phi})$ were evaluated and compared with other results. As the results, the FI was determined to be 1.061 at ${\theta}=90^{\circ}$ with ${\pm}0.2%$ statistical error and the $(H/{\Phi})$ was evaluated to be $333.9 [pSv\;cm^2]\;with\;{\pm}0.5%$ statistical error, which is lower by 1.8% than that recommended by the ISO 8529. This means physically that the neutron spectrum of the unmoderated $^{252}Cf$ source in KAERI is a little more softened than that by the ISO.

  • PDF

Standard Neutron Irradiation Facility for Calibration of Radiation Protection Instruments by Radioactive Neutron Sources (방사성 중성자선원에 의한 방사선방어측정기의 교정을 위한 표준 중성자 조사장치 연구)

  • Choi, Kil-Oung;Lee, Kyung-Ju;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.66-70
    • /
    • 1989
  • In routine testing, the radioactive neutron sources are particularly suitable for producing standard. neutron fields. The ISO TC-85 has proposed neutron reference radiation for the calibration of neutron measuring devices used for radiation protection purposes. Radiation laboratory of KSRI has installed a standard irradiation facility using $^{252}Cf$ and $^{241}Am-Be$ sources for calibrating personal dosimeters according to the recommendations given in ISO TC-85. In this study, correction factors for calibration related to neutron scattering and anisotropy are obtained by experiments with commercial rem meter for demonstration purposes.

  • PDF

Comparison Study of Experimental Neutron Room Scattering Corrections with Theoretical Corrections in RCL's Calibration Facility at KAERI (한국원자력연구소 중성자교정실에 대한 중성자산란보정인자 결정연구)

  • Yoon, Suk-Chul;Chang, Si-Young;Kim, Jong-Soo;Kim, Jang-Lyul;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.1
    • /
    • pp.29-33
    • /
    • 1997
  • Neutron room scattering corrections that should be made when neutron detectors are calibrated with a $D_2O$ moderated $^{252}Cf$ neutron source in the center of a calibration room are considered. Such room scattering corrections are dependent on specific neutron source type, detector type, calibration distance, and calibration room configuration. Room scattering corrections for the responses of a thermoluminescence dosimeter and two different types of spherical detectors to neutron source in the Radiation Calibration Laboratory(RCL) neutron calibration facility at the Korea Atomic Energy Research Institute(KAERI) were experimentally determined and are presented. The measured room scattering results are then compared with theoretical results calculated by predicting room scattering effects in terms of parameters related to the specific configuration. Agreement between measured and calculated scattering correction is generally about 10% for three kinds of detectors in the calibration facility.

  • PDF

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.

Neutron Dose Measurements Using TLDs in a 252Cf Neutron Field (252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정)

  • Chang, Insu;Kim, Sang In;Lee, Jung Il;Kim, Jang Lyurl;Kim, Bong Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • In case of neutron dose measurement using TLDs (thermo-luminescence dosimeters), because the neutron energy dependence of the TLD is very high, the calibration of the energy response according to the characteristics of the neutron spectrum of workplace is required. In the present study, the ambient dose equivalent rates inside and around the Long-Counter (neutron detector) with narrow and complex inside in the neutron field of $^{252}Cf$ were evaluated. The calibration factors to account for the neutron energy dependence of TLDs were established for both the bare and $D_2O$ modulated $^{252}Cf$ neutron beams, respectively. The values of the TLD's measurement were compared with the computational results of the MCNPX (Monte Carlo N-Particles transport code). When using the two calibration factors of the TLD than a single calibration factor, the measured and the calculated values at the point of verification outside and inside the Long-Counter were in more good agreement. This results show that TLD should be calibrated in the reference neutron field similar to workplace situation.

성토다짐의 밀도 및 수분 측정에 관한 연구

  • 김기준
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.38-46
    • /
    • 2002
  • 본 연구에서는 성토 다짐용 밀도 및 수분의 측정을 위하여 중성자 검출기는 2개 이상 그리고 감마선 검출기는 5개 이상 사용하여 함을 알 수 있었고, 또한 방사능 대비 방사선 방출수가 다른 선원에 비하여 우수한 Co-60 감마선원과 Cf-252 중성자 선원을 본 계기에 이용하는 것이 정밀도를 향상시키기 위하여 유리하다는 것을 알 수 있었다. 본 연구에서 설계하고 제작한 성토 다짐용관리용 밀도 및 수분 함량 측정기는 국내의 도로 공사 현장에서 성토의 다짐관리를 위하여 이용될 수 있을것으로 사료된다.

  • PDF