• Title/Summary/Keyword: $^{18}FDG$ PET-CT

Search Result 350, Processing Time 0.031 seconds

CLINICAL STUDY OF POSITRON EMISSION TOMOGRAPHY WITH $[^{18}F]$-FLUORODEOXYGLUCOSE IN MAXILLOFACIAL TUMOR DIAGNOSIS (구강 악안면 영역의 암종 진단에 있어서 $[^{18}F]$-Fluorodeoxyglucose를 이용한 양전자방출 단층촬영의 임상적 연구)

  • Kim, Jae-Hwan;Kim, Kyung-Wook;Kim, Yong-Kack
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.462-469
    • /
    • 2000
  • Positron Emission Tomography(PET) is a new diagnostic method that can create functional images of the distribution of positron emitting radionuclides, which when administered intravenously in the body, makes possible anatomical and functional analysis by quantity of biochemical and physiological process. After genetic and biochemical changes in initial stage, malignant tumor undergoes functional changes before undergoing anatomical changes. So, early diagnosis of malignant tumors by functional analysis with PET can be achieved, replacing traditional anatomical analysis, such as computed tomography(CT) and magnetic resonance image(MRI), etc. Similarly, PET can identify malignant tumor without confusion with scar and fibrosis in follow up check. In the Korea Cancer Center Hospital(KCCH) from October 1997 to September 1999, clinical study was performed in 79 cases that underwent 89 times PET evaluation with [18F]-Fluorodeoxyglucose for diagnosis of oral and maxillofacial tumors, and the data was analysed by Bayesian $2{\times}2$ Classification Table. The results were as follows : Evaluation for initial diagnosis with FDG-PET (P<0.005) 1. Agreement rate or accuracy rate is 88.9%. 2. Sensitivity is 95.2%, and specificity 66.7%. 3. Positive predictive rate is 90.9%, and negative predictive rate 80.0%. 4. In consideration of tumor stage, diagnostic rate in less than stage II was 90% and in greater than stage III 100%. 5. In consideration of tumor size, diagnostic rate in less than T2 was 92.3% and in greater than T3 100%. After primary treatment, evaluation for follow up check with FDG-PET (P < 0.001) 1. Agreement rate or accuracy rate is 85.4%. 2. Sensitivity is 87.5%, and specificity 82.4%. 3. Positive predictive rate is 87.5%, and negative predictive rate 82.4%. 4. In 24 recurred cases, 6 had distant metastasis, and 5 of them were diagnosed with FDG-PET, resulting in diagnostic rate of FDG-PET of 83.3%. From the above results, Positron Emission Tomography with [18F]- Fluorodeoxyglucose appears to be more sensitive and accurate for detecting the presence of oral and maxillofacial tumors, and has various clinical applications such as early diagnosis of tumor in initial and follow up check and detection of distant metastasis.

  • PDF

Evaluation of the Apron Effectiveness during Handling Radiopharmaceuticals in PET/CT Work Environment (PET/CT 업무 환경에서 선원 취급 시 Apron의 실효성 평가)

  • Cho, Yong-In;Ye, Soo-Young;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.237-244
    • /
    • 2015
  • Health professionals in nuclear medicine were known that they get high radiation exposure. To reduce radiation exposure, using shielding materials is needed. In this study, we analyzed the shielding effect about apron during 18F-FDG treatment by using simulation based on Monte Carlo techniques and actual measurement. As a result, absorbed dose distribution of organ varies with handling position of the source. Dose reduction ratio by lead thickness of apron tended to decease, when handling position of the source come close to organ and away from radiation source for simulation. In the case of actual measurement with the dosimetry device, It showed that mean spatial dose distribution was different due to characteristics of dosimetry device. However, spatial dose rate was exponentially reduced according to distance with increasing lead content.

A Study on the Improvement for Medical Service Using Video Promotion Materials for PET/CT Scans (PET/CT 검사에서 동영상 홍보물을 통한 의료서비스 향상에 관한 연구)

  • Kim, Woo Hyun;Kim, Jung Seon;Ko, Hyun Soo;Sung, Ji Hye;Lee, Jeoung Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Purpose: One of the current services, providing information to the patients and their guardians by using promotion materials induces positive responses and contributes to the improvement of the hospital reliability. Therefore, the objective of this study is to evaluate the effectiveness of audio visual materials, one of the means of promotion, as a way to give accurate medical information to resolve patient's curiosity about purpose and procedure of their examination and deplete complains about waiting which attributes negative effect to service quality assessment. Materials and Methods: 60 patients(mean age $53.97{\pm}12.24$, male : female = 26 : 34) who had $^{18}F-FDG PET/CT$ scan from July 2012 to August 2012 in Seoul Asan Medical Center were referred to the study. All of the patients having PET/CT scan were asked to watch an informative video material before the injection of radiopharmaceutical ($^{18}F-FDG$) and to fill in a questionnaire. Results: As a result of analyzing the contents of questionnaire, 52% of 60 patients had PET/CT scan for the first time and 72.4% of the patients read the PET/CT guidebook offered from their outpatient department or inpatient wards before their scan. After we searched the level of previous knowledge of the purpose and method of PET/CT scan, the patients answered 25.1% "know well", 34% "not sure", 40.9% "don't know" respectively. And 84.7% of the patients answered that watching the PET/CT guide video before the injection helps understanding what exam they were having and 15.3% of the patients did not. For the question asking ever the patients have experienced using our homepage or smart phone QR code to see the guide video before they visit out PET center, only 3.3% of them answered "yes". Lastly, the patients answered 60.1% "yes", 31.4% "so so" and 8.5% "no" respectively for the question asking whether watching the video makes the patients to fill the waiting time short. Conclusion: It is found that understanding of objective and method of the PET/CT scan and level of satisfaction was improved after the patients watched the guide video whether they had PET/CT scan before and read the PET/CT guidebook or not. Also, watching the video was effective for the reduction of perceptible waiting time. But while displaying the PET/CT guide video is useful for providing information about the scan and shortening the waiting time as one of the medical service, utilization of service was actually very poor because of the passive promotion and indifference of the patients about their examination. Therefore, from now on, it is necessary to construct the healthcare system which can be offered to more patients through the active promotion.

  • PDF

Anticancer Activity of Atractylodes lancea (Thunb.) DC in a Hamster Model and Application of PET-CT for Early Detection and Monitoring Progression of Cholangiocarcinoma

  • Plengsuriyakarn, Tullayakorn;Matsuda, Naoki;Karbwang, Juntra;Viyanant, Vithoon;Hirayama, Kenji;Na-Bangchang, Kesara
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6279-6284
    • /
    • 2015
  • Opisthorchis viverrini (OV)-induced cholangiocarcinoma (CCA) is an important cancer in the Great Mekong region, particularly in Thailand. Limitations of treatment options and the lack of an effective diagnostic tool for early detection of CCA are major concerns for the control of this type of cancer. The aim of the study was to investigate anti-CCA activity of the ethanolic extract of Atractylodes lancea (Thunb.) DC., and the applicability of positron emission tomography-computed tomography (PET-CT) as a tool for detection and monitoring the progression of CCA in Opisthorchis viverrini (OV)/dimethylnitrosamine (DMN)-induced CCA hamsters. Male Syrian hamsters were used for toxicity tests and anti-CCA activity evaluation. Development of CCA was induced by initial feeding of 50 metacercariae of OV, followed by drinking water containing 12.5 ppm of DMN in hamsters. The ethanolic extract of A. lancea (Thunb.) DC. was administered orally for 30 days. PET-CT was performed every 4 weeks after initiation of CCA using 18F-fluorodeoxyglucose ($^{18}F-FDG$). Results from the present study suggest that the ethanolic extract of A. lancea (Thunb.) DC. rhizome exhibited promising anti-CCA activity and safety profile in the OV/DMN-induced hamster model. To successfully apply PET-CT as a tool for early detection of tumor development and progression, modification of radiolabeling approach is required to improve its specificity for CCA cells.

A Case of Pulmonary Paragonimiasis Presented as Solitary Pulmonary Nodule and Suspected as Lung Cancer on 18F-Fluorodeoxyglucose Positron Emission Tomography (양전자 방출 단층촬영에서 폐암으로 의심되었던 고립 폐 결절 형태의 폐흡충증 1예)

  • Moon, Jae Young;Jung, Ki Hwan;Kim, Je Hyeong;Park, Hyung Joo;Kim, Young Sik;Shin, Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.2
    • /
    • pp.133-137
    • /
    • 2008
  • Pulmonary paragonimiasis continues to be a diagnostically challenging parasitic disease, despite a drastically decreased prevalence in South Korea during the past decade. Pulmonary paragonimiasis is characterized by fever, chest pain, and chronic cough with hemoptysis. Numerous radiographic and computed tomographic findings including the presence of pneumothorax, pleural effusion, and parenchymal lesions such as nodular or infiltrative opacities have been reported. The clinical and radiological manifestations of paragonimiasis can resemble those of lung cancer, tuberculosis or a metastatic malignancy. Furthermore, this disease can mimic lung cancer as seen on $^{18}F$-fluorodeoxyglucose positron emission tomography (FDG-PET). We report a case of pulmonary paragonimiasis in a 48-year old man that presented with a solitary pulmonary nodule and was suspected as a lung cancer based on FDG-PET imaging.

Examination about Utility of Prone Position in PET/CT of Stomach Cancer Patient (위암 환자의 양전자 방출 컴퓨터 단층 검사에서 복와위(伏臥位) 촬영의 유용성에 대한 연구)

  • NamKoong, Hyuk;Park, Hoon-Hee;Oh, Shin-Hyun;Bahn, Yung-Kag;Kim, Jung-Yul;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.93-99
    • /
    • 2010
  • Purpose: Currently, PET/CT scan has been known to provide useful information to both preoperative and postoperative examination of cancer patients. Contracted stomach by the long fasting could cause difficulties of interpretation because of its size on reconstructed image data. To solve this problem, after the whole body PET/CT scan, patients were administrated in drinking 300 mL of water to expand stomach and performed additional scan on stomach region. Not only PET/CT scan but also CT performs this water-administration, and patients were take oral solution to make stomach expand for stomach cancer. When this scan performed, patients lay supine position. In this study, we evaluated the capacity of stomach through PET/CT scan with drinking water performed in supine and prone position so that we can distinguish exact location of cancer around pylorus and inferior wall of stomach. Furthermore, image data from supine and prone positions were analyzed the difference of volume of stomach through the change of standardized uptake values. Materials and Methods: From July 2009 to January 2010 in severance hospital, 30 patients who were diagnosed as early gastric cancer or advanced gastric cancer were chosen. All patients had PET/CT scan before the operation and have had follow-up PET/CT. The patients fast for at least 8 hours, and had an injection intravenously with $^{18}F$-FDG, 7.4 MBq (0.2 mCi/kg) per kilogram. They were rested for 60 minutes. Before the examination, all patients were administrated to drink water for 300 mL Patients had PET/CT scan with supine position around the region of stomach, whole body, and around the region of stomach with prone position after drinking another 300 mL of water respectively. Results: As a results of comparison between stomach capacity of 30 patients in supine and prone position, the study draw results that average capacity of stomach body was 460.29 $mm^2$ in supine position, and 641.39 $mm^2$ in prone position for 30 patients. The change of capacity shows 41.3% expanded in prone position. And there was no noticeable difference at maximum standardized uptake values in supine position and prone position. Conclusion: As results, stomach would have more expanded capacity in prone position than supine position. For patients who have physical disabilities to move freely, additional scan in prone position will be obstacle to perform. However, if additional scan in supine position add with the scan in prone position, it will be easier to diagnose stomach cancer. Moreover, we believe that this study will help the research for inventing support tools for patients who have physical disabilities in prone position.

  • PDF

Distinguishing between Thymic Epithelial Tumors and Benign Cysts via Computed Tomography

  • Sang Hyup Lee;Soon Ho Yoon;Ju Gang Nam;Hyung Jin Kim;Su Yeon Ahn;Hee Kyung Kim;Hyun Ju Lee;Hwan Hee Lee;Gi Jeong Cheon;Jin Mo Goo
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.671-682
    • /
    • 2019
  • Objective: To investigate whether computed tomography (CT) and fluorine-18-labeled fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) may be applied to distinguish thymic epithelial tumors (TETs) from benign cysts in the anterior mediastinum. Materials and Methods: We included 262 consecutive patients with pathologically proven TETs and benign cysts 5 cm or smaller who underwent preoperative CT scans. In addition to conventional morphological and ancillary CT findings, the relationship between the lesion and the adjacent mediastinal pleura was evaluated qualitatively and quantitatively. Mean lesion attenuation was measured on CT images. The maximum standardized uptake value (SUVmax) was obtained with FDG-PET scans in 40 patients. CT predictors for TETs were identified with multivariate logistic regression analysis. For validation, we assessed the diagnostic accuracy and inter-observer agreement between four radiologists in a size-matched set of 24 cysts and 24 TETs using a receiver operating characteristic curve before and after being informed of the study findings. Results: The multivariate analysis showed that post-contrast attenuation of 60 Hounsfield unit or higher (odds ratio [OR], 12.734; 95% confidence interval [CI], 2.506-64.705; p = 0.002) and the presence of protrusion from the mediastinal pleura (OR, 9.855; 95% CI, 1.749-55.535; p = 0.009) were the strongest CT predictors for TETs. SUVmax was significantly higher in TETs than in cysts (5.3 ± 2.4 vs. 1.1 ± 0.3; p < 0.001). After being informed of the study findings, the readers' area under the curve improved from 0.872-0.955 to 0.949-0.999 (p = 0.066-0.149). Inter-observer kappa values for protrusion were 0.630-0.941. Conclusion: Post-contrast CT attenuation, protrusion from the mediastinal pleura, and SUVmax were useful imaging features for distinguishing TETs from cysts in the anterior mediastinum.

Evaluation of SUV Which was Estimated Using Mini PACS by PET/CT Scanners (PET/CT 장비 별 mini PACS에서 측정한 표준섭취계수(SUV)의 유용성 평가)

  • Park, Seung-Yong;Ko, Hyun-Soo;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.47-52
    • /
    • 2011
  • Purpose: Facilities use own sever or mini PACS system for storage and analysis of the PET/CT data. Mini PACS can storage scan data as well as measuring SUV. Therefore, the study was performed to confirm whether or not measured SUV on mini PACS is measured equally on PET/CT workstation. Materials and Methods: In February 2011, 30 patients who were performed $^{18}F$-FDG wholebody PET/CT scan in Biograph 16, Biograph 40 and Discovery Ste 8 were enrolled. First, using each workstation, SUV in liver and aorta of mediastinum level was measured. Second, using mini PACS, SUV was measured by same method. Result: The correlation coefficient of SUV in liver between PET/CT scanner and min PACS in Biograph 16, Biograph 40, Discovery Ste 8 was 0.99, 0.98, 0.64 respectably, the correlation coefficient of SUV in aorta was 0.98, 0.98, 0.66, and these were showed positive correlation coefficient. Difference of SUV between Biograph workstation and mini PACS was not showed statistical significant difference at 5% level of significance. Difference of SUV between Discovery Ste 8 workstation and mini PACS was showed statistical significant difference at 5% level of significance. Conclusion: In case that patient was scanned by the other scanner, if the correction of SUV formula in mini PACS for each scanners is performed, mini PACS will be usefully used to provide consistently quantitative assessment.

  • PDF

Efficacy of Positron Emission Tomography in Diagnosing Pulmonary Tumor and Staging of Lung Cancer : Comparing to Computed Tomography (폐종양과 폐암의 병기결정에 대한 양전자단층촬영(PET)의 유용성 -전산화단층촬영 (CT)과의 비교-)

  • 김오곤;조중행;성숙환
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Diagnosing and determining the stage of lung cancer by means of positron emission tomography (PET) ha.. been proven valuable because of the limitations of diagnosis by computed tomography (CT). We compared the efficacy of PET with that of CT in diagnosing pulmonary tumor and staging of lung cancer Material and Method: We performed F-18 FDG PET to determine the malignancy and the staging on patients who have been suspicious or were diagnosed as lung cancer by chest X-ray and CT. The findings of PET and of CT of 41 patients (male, 29: female, 12: mean age, 59) were compared with pathologic findings obtained from a mediastinoscopy and thoracotomy. Result: Out of 41 patients, 35 patients had malignant lesions (squamous cell carcinonla 19 cases, adenocarcinoma 14 cases, adenosquamous cell carcinoma 2 cases) and 6 patients had benign lesions. Diagnosing of lung cancer, the sensitivity, specificity and accuracy of CT and PET were the same for two method and the numbers were 100%, 50%, and 92.7% respectively. Eighteen LN groups out of 108 mediastinal LN groups who recieved histologic examination proved to be malignant. Pathologic lymph node (LN) stage was N0-Nl 31 cases, N2 8 cases, N3 2 cases. The correct identification of the nodal staging with CT, PET scans were 31 cases (75.6%), 28 cases (68.3%) respectively. The LN group was underestimated in each 6 cases of CT and PET. In 4 cases of CT and 7 cases of PET, they were overestimated in compare to histologic diagnosis. In the detection of mediastinal LN groups invasion, the sensitivity, specificity and accuracy of CT were 39.8 %, 93.3 %, and 84.3 % respectively. For PET, they were 61.1 %, 90.0 %, and 85.2 %. When two methods considered together (CT+PET), they were increased to 77.8 %, 93.3 %, and 90.7 % respectively. Conclusion: PET appears to be similar to CT in the diagnosis and the nodal taging of pulmonary tumor. Two tests may stage patients with lung cancer more accurately than CT alone.

Metal artifact SUV estimation by using attenuation correction image and non attenuation correction image in PET-CT (PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰)

  • Kim, June;Kim, Jae-II;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.21-26
    • /
    • 2016
  • Purpose Because of many advantages, PET-CT Scanners generally use CT Data for attenuation correction. By using CT based attenuation correction, we can get anatomical information, reduce scan time and make more accurate correction of attenuation. However in case metal artifact occurred during CT scan, CT-based attenuation correction can induce artifacts and quantitative errors that can affect the PET images. Therefore this study infers true SUV of metal artifact region from attenuation corrected image count -to- non attenuation corrected image count ratio. Materials and Methods Micro phantom inserted $^{18}F-FDG$ 4mCi was used for phantom test and Biograph mCT S(40) is used for medical test equipment. We generated metal artifact in micro phantom by using metal. Then we acquired both metal artifact region of correction factor and non metal artifact region of correction factor by using attenuation correction image count -to- non attenuation correction image count ratio. In case of clinical image, we reconstructed both attenuation corrected images and non attenuation corrected images of 10 normal patient($66{\pm}15age$) who examined PET-CT scan in SNUH. After that, we standardize several organs of correction factor by using attenuation corrected image count -to- non attenuation corrected count ratio. Then we figured out metal artifact region of correction factor by using metal artifact region of attenuation corrected image count -to- non attenuation corrected count ratio And we compared standard organs correction factor with metal artifact region correction factor. Results according to phantom test results, metal artifact induce overestimation of correction factor so metal artifact region of correction factors are 12% bigger than the non metal artifact region of correction factors. in case of clinical test, correction factor of organs with high CT number(>1000) is $8{\pm}0.5%$, correction factor of organs with CT number similar to soft tissue is $6{\pm}2%$ and correction factor of organs with low CT number(-100>) is $3{\pm}1%$. Also metal artifact correction factors are 20% bigger than soft tissue correction factors which didn't happened metal artifact. Conclusion metal artifact lead to overestimation of attenuation coefficient. because of that, SUV of metal artifact region is overestimated. Thus for more accurate quantitative evaluation, using attenuation correction image count -to-non attenuation correction image count ratio is one of the methods to reduce metal artifact affect.

  • PDF