• Title/Summary/Keyword: $^{14}C$ Radionuclide

Search Result 21, Processing Time 1.943 seconds

Gasification Characteristics to $^{14}CO_2\;of\;^{14}C$ Radionuclide Desorbed from Spent Resin by Phosphate Solutions (월성 원전발생 폐수지로부터 제거된 $^{14}C$ 핵종의 인산용액을 이용한 $^{14}CO_2$로의 기체화 특성)

  • Yang, Ho-Yeon;Won, Jang-Sik;Choi, Young-Ku;Park, Geun-Il;Kim, In-Tae;Kim, Kwang-Wook;Song, Kee-Chan;Park, Hwan-Seo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.311-320
    • /
    • 2006
  • Removal characteristics of $H^{14}CO_3$ ion from IRN-150 mixed resin contaminated with $^{14}C$ radionuclide and a gasification behavior of $^{14}C$ radionuclide to $^{14}CO_2$ were investigated. The stripping solutions used for the removal of $^{14}C$ from spent resin were $NaNO_3,\;Na_3PO_4,\;NH_4H_2PO_4,\;H_3PO_4$. The influence of stripping solution concentration on the desorption characteristics of inactive $HCO_3$ ion into stripping solution from IRN-150 mixed resin and the gasification of this ion to $CO_2$ was analyzed. The gasification behavior to $CO_2$ by using NaOH, $HNO_3$, HCl was also compared to that of phosphate solution. Real spent resin stored in Wolsung nuclear power plant was used to evaluate the gasification characteristics of $^{14}C$ radionuclide to $^{14}CO_2$. Gamma radionuclides such as $^{137}Cs,\;^{60}Co$ in residual striping solutions after desorption experiment were analyzed.

  • PDF

Ion Adsorption Characteristics of IRN-150 Mixed Resin and Removal Behavior of $^{14}C$ Radionuclide from Spent Resin by Stripping Solutions (IRN-150 혼상수지의 이온 흡착특성 및 폐수지로부터 탈착용액을 이용한 $^{14}C$ 핵종의 제거 특성)

  • Yang, Ho-Yeon;Won, Jang-Sik;Choi, Young-Ku;Park, Geun-Il;Kim, In-Tae;Kim, Kwang-Wook;Song, Kee-Chan;Park, Hwan-Seo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.373-384
    • /
    • 2006
  • Spent ion-exchanged resin generated from various purification systems in CANDU reactor was contaminated with high activity of $^{14}C$ radionuclide. This paper describes the results of fundamental study to develop the applicable technology for the treatment of this spent resin. Based on the adsorption capacity of inactive $HCO_3$ ion and other anions on IRN-150 mixed resin, the removal characteristics of $HCO_3$ ion adsorbed on to IRN-150 by various stripping solutions were evaluated. Maximum adsorption amount of the $HCO_3$ ion onto IRN-150 raw resin was about 11 mg-C/g-resin which agrees with the theoretical adsorption amount of this resin. Adsorption affinity of various anions such as $CS,\;CO,\;Na\;NH_4$ was analyzed in single and multi-component systems. From the results of removal characteristics of the $HCO_3$ ion adsorbed on IRN-150 by various stripping solutions, $NH_4H_2PO_4$ stripping solution is more effective than $NaNO_3,\;Na_3PO_3$ solutions for the complete removal of $^{14}C$ radionuclide from the IRN-150 spent resin.

  • PDF

A Study on the Radionuclide Cardiac Angiography in the Various Heart Diseases (각종(各種) 심질환(心疾患)에서 방사성(放射性) 동위원소(同位元素) 심혈관촬영술(心血管撮影術)에 관한 연구(硏究))

  • Chung, June-Key;Park, Sun-Yang;Ryu, Park-Young;Cho, Bo-Yeon;Kim, Byoung-Kuk;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.13 no.1_2
    • /
    • pp.7-14
    • /
    • 1979
  • Radionuclide cardiac angiography has distinct advantages in safety, patient comfort, cost and ease of performance. This method offers diagnostic accuracy equivalent to that of cardiac catheterization. By this method the qualitative and quantitative diagnosis of the cardiac shunts are available. Also for it is repeatable with ease and more physiologic, it has application in following pre- and post-operative shunt patients. We performed the radionuclide cardiac angiographies in 147 cases of heart diseases and 26 cases of normal group. 1. The detection of left-to-right shunt was possible in 22 of 24 patients, and 2 patients were not diagnosed due to small shunt amount. (Qp/Qs<1.3) In 21 patients of right-to-left shunt, all were diagnosed by radionuclide cardiac angiography. 2. With the pulmonary time-activity curve, $C_2/C_1$ ratio was calculated. In normal control group, a range of $C_2/C_1$ ratios of $21{\sim}38%$ was established with a mean value of $28.6{\pm}4.6%$. In patients with left-to-right shunts determined by catheterization data, the range of $C_2/C_1$ ratio was $33{\sim}90%$, with a mean value of $67.8{\pm}12.2%$. 3. In 8 cases of left-to-right shunt, $Q_p/Q_s$ ratios determined by radionuclide cardiac angiography were compaired with those of cardiac catheterization. The correlation coefficient was 0.907. (P<0.001) 4. Postoperative radionuclide cardiac angiographies were done in 21 cases. 3 of 13 patients with left-to-right shunts were found to have residual shunts. 8 patients with right-to-left shunts were confirmed to have no residual shunt.

  • PDF

Simulation of the Migration of 3H and 14C Radionuclides on the 2nd Phase Facility at the Wolsong LILW Disposal Center

  • Ha, Jaechul;Son, Yuhwa;Cho, Chunhyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.4
    • /
    • pp.439-455
    • /
    • 2020
  • Numerical model was developed that simulates radionuclide (3H and 14C) transport modeling at the 2nd phase facility at the Wolsong LILW Disposal Center. Four scenarios were simulated with different assumptions about the integrity of the components of the barrier system. For the design case, the multi-barrier system was shown to be effective in diverting infiltration water around the vaults containing radioactive waste. Nevertheless, the volatile radionuclide 14C migrates outside the containment system and through the unsaturated zone, driven by gas diffusion. 3H is largely contained within the vaults where it decays, with small amounts being flushed out in the liquid state. Various scenarios were examined in which the integrity of the cover barrier system or that of the concrete were compromised. In the absence of any engineered barriers, 3H is washed out to the water table within the first 20 years. The release of 14C by gas diffusion is suppressed if percolation fluxes through the facility are high after a cover failure. However, the high fluxes lead to advective transport of 14C dissolved in the liquid state. The concrete container is an effective barrier, with approximately the same effectiveness as the cover.

A STUDY ON ADSORPTION AND DESORPTION BEHAVIORS OF 14C FROM A MIXED BED RESIN

  • Park, Seung-Chul;Cho, Hang-Rae;Lee, Ji-Hoon;Yang, Ho-Yeon;Yang, O-Bong
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.847-856
    • /
    • 2014
  • Spent resin waste containing a high concentration of $^{14}C$ radionuclide cannot be disposed of directly. A fundamental study on selective $^{14}C$ stripping, especially from the IRN-150 mixed bed resin, was carried out. In single ion-exchange equilibrium isotherm experiments, the ion adsorption capacity of the fresh resin for non-radioactive $HCO_3{^-}$ ion, as the chemical form of $^{14}C$, was evaluated as 11mg-C/g-resin. Adsorption affinity of anions to the resin was derived in order of $NO_3{^-}$ > $HCO_3{^-}{\geq}H_2PO_4{^-}$. Thus the competitive adsorption affinity of $NO_3{^-}$ ion in binary systems appeared far higher than that of $HCO_3{^-}$ or $H_2PO_4{^-}$, and the selective desorption of $HCO_3{^-}$ from the resin was very effective. On one hand, the affinity of $Co^{2+}$ and $Cs^+$ for the resin remained relatively higher than that of other cations in the same stripping solution. Desorption of $Cs^+$ was minimized when the summation of the metal ions in the spent resin and the other cations in solution was near saturation and the pH value was maintained above 4.5. Among the various solutions tested, from the view-point of the simple second waste process, $NH_4H_2PO_4$ solution was preferable for the stripping of $^{14}C$ from the spent resin.

Radionuclide Diffusion in Compacted Domestic Bentonite (압축 국산 벤토나이트 내에서 방사성 핵종의 확산이동)

  • Choi, Jong-Won;Lee, Byung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.27-39
    • /
    • 1991
  • The diffusion of Sr-85, Cs-137, Co-60 and Am-241 in compacted domestic bentonite was studied, using a diffusion cell unit in which diffusion took place axially from the center of cylindrical bentonite sample body. The effects of compaction density and heat-treated bentonite on diffusion were analysed. And the diffusion mechanism of radionuclide was also analysed by evaluating the measured diffusivity of anion Cl-36. The apparent diffusivities obtained for Sr-85, Cs-137, Co-60 and Am-241 were $l.07{\times}10^{-11},\;6.705{\times}10^{-13},\;l.226{\times}10^{-13}\;and\; l.310{\times}10^{-14}m^2/sec$, respectively. When the as-pressed density of bentonite increased from $1.8\;to\;2.0g/cm^3$, the apparent diffusivity of Cs-137 decreased by quarter. In the case of bentonite heat-treated to $150^{\circ}C$, no significant change in diffusivity was observed, which showed the possibility that the domestic bentonite could be used as a chemical barrier to retard the radionuclide migration at below $150^{\circ}C$. From the calculated pore and surface diffusivity, the surface diffusion due to the concentration gradient of radionuclide sorbed on the solid phase was found to dominate greatly in total transport process.

  • PDF

Radionuclide identification method for NaI low-count gamma-ray spectra using artificial neural network

  • Qi, Sheng;Wang, Shanqiang;Chen, Ye;Zhang, Kun;Ai, Xianyun;Li, Jinglun;Fan, Haijun;Zhao, Hui
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.269-274
    • /
    • 2022
  • An artificial neural network (ANN) that identifies radionuclides from low-count gamma spectra of a NaI scintillator is proposed. The ANN was trained and tested using simulated spectra. 14 target nuclides were considered corresponding to the requisite radionuclide library of a radionuclide identification device mentioned in IEC 62327-2017. The network shows an average identification accuracy of 98.63% on the validation dataset, with the gross counts in each spectrum Nc = 100~10000 and the signal to noise ratio SNR = 0.05-1. Most of the false predictions come from nuclides with low branching ratio and/or similar decay energies. If the Nc>1000 and SNR>0.3, which is defined as the minimum identifiable condition, the averaged identification accuracy is 99.87%. Even when the source and the detector are covered with lead bricks and the response function of the detector thus varies, the ANN which was trained using non-shielding spectra still shows high accuracy as long as the minimum identifiable condition is satisfied. Among all the considered nuclides, only the identification accuracy of 235U is seriously affected by the shielding. Identification of other nuclides shows high accuracy even the shielding condition is changed, which indicates that the ANN has good generalization performance.

Desorption Characteristics of $H^{14}CO_3$ ion from Spent Ion Exchanged Resin by Solution Stripping Technology

  • Park Geun-IL;Kim In-Tae;Kim Kwang-Wook;Lee Jung-Won;Won Jang-Sik;Yang Ho-Yeon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.214-221
    • /
    • 2005
  • Spent ion-exchanged resin generated from various purification systems in CANDU reactor is causing concern due to a limited storage capacity and safe disposal. As a suggestion for a proper treatment technology for the spent ion-exchanged resin containing a high activity of C­14 radionuclide which would be classified as Class A and C wastes, a fundamental study for the development of C-14 removal technology from a spent resin was performed. The adsorption characteristics of the inactive $HCO_3^-$ ion and other ions in a stripping solution on IRN-150 mixed resin was evaluated and the removal technology of the $HCO_3^-$ ion adsorbed on IRN-150 by an alkaline stripping method was proposed.

  • PDF

Radiochemical Analysis of Filters Used During the Decommissioning of Research Reactors for Disposal

  • Kyungwon Suh;Jung Bo Yoo;Kwang-Soon Choi;Gi Yong Kim;Simon Oh;Kanghyun Yoo;Kwang Eun Lee;Shinkyoung Lee;Young Sang Lee;Hyeju Lee;Junhyuck Kim;Kyunghun Jung;Sora Choi;Tae-Hong Park
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.489-500
    • /
    • 2022
  • The decommissioning of nuclear facilities produces various types of radiologically contaminated waste. In addition, dismantlement activities, including cutting, packing, and clean-up at the facility site, result in secondary radioactive waste such as filters, resin, plastic, and clothing. Determining of the radionuclide content of this waste is an important step for the determination of a suitable management strategy including classification and disposal. In this work, we radiochemically characterized the radionuclide activities of filters used during the decommissioning of Korea Research Reactors (KRRs) 1 and 2. The results indicate that the filter samples contained mainly 3H (500-3,600 Bq·g-1), 14C (7.5-29 Bq·g-1), 55Fe (1.1- 7.1 Bq·g-1), 59Ni (0.60-1.0 Bq·g-1), 60Co (0.74-70 Bq·g-1), 63Ni (0.60-94 Bq·g-1), 90Sr (0.25-5.0 Bq·g-1), 137Cs (0.64-8.7 Bq·g-1), and 152Eu (0.19-2.9) Bq·g-1. In addition, the gross alpha radioactivity of the samples was measured to be between 0.32-1.1 Bq·g-1. The radionuclide concentrations were below the concentration limit stated in the low- and intermediatelevel waste acceptance criteria of the Nuclear Safety and Security Commission, and used for the disposal of the KRRs waste drums to a repository site.

The Evaluation of Difference according to Image Scan Duration in PET Scan using Short Half-Lived Radionuclide (단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가)

  • Hong, Gun-Chul;Cha, Eun-Sun;Kwak, In-Suk;Lee, Hyuk;Park, Hoon;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.102-107
    • /
    • 2012
  • Purpose : Because of the rapid physical decay of the short half-lived radionuclide, counting of event for image is very limited. In this reason, long scan duration is applied for more accurate quantitative analysis in the relatively low sensitive examination. The aim of this study was to evaluate the difference according to scan duration and investigate the resonable scan duration using the radionuclide of 11C and 18F in PET scan. Materials and Methods : 1994-NEMA Phantom was filled with 11C of $30.08{\pm}4.22MBq$ and 18F of $40.08{\pm}8.29MBq$ diluted with distilled water. Dynamic images were acquired 20frames/1minute and static image was acquired for 20minutes with 11C. And dynamic images were acquired 20frames/2.5minutes and static image was acquired for 50minutes with 18F. All of data were applied with same reconstruction method and time decay correction. Region of interest (ROI) was set on the image, maximum radioactivity concentration (maxRC, kBq/mL) was compared. We compared maxRC with acquired dynamic image which was summed one bye one to increase the total scan duration. Results : maxRC over time of 11C was $3.85{\pm}0.45{\sim}5.15{\pm}0.50kBq/mL$ in dynamic image, and static image was $2.15{\pm}0.26kBq/mL$. In case of 18F, the maxRC was $9.09{\pm}0.42{\sim}9.48{\pm}0.31kBq/mL$ in dynamic image and $7.24{\pm}0.14kBq/mL$ in static. In summed image of 11C, as total scan duration was increased to 5, 10, 15, 20minutes, the maxRC were $2.47{\pm}0.4$, $2.22{\pm}0.37$, $2.08{\pm}0.42$, $1.95{\pm}0.55kBq/mL$ respectively. In case of 18F, the total scan duration was increased to 12.5, 25, 37.5, and 50minutes, the maxRC were $7.89{\pm}0.27$, $7.61{\pm}0.23$, $7.36{\pm}0.21$, $7.31{\pm}0.23kBq/mL$. Conclusion : As elapsed time was increased after completion of injection, the maxRC was increased by 33% and 4% in dynamic study of 11C and 18F respectively. Also the total scan duration was increased, the maxRC was reduced by 50% and 20% in summed image of 11C and 18F respectively. The percentage difference of each result is more larger in study using relatively shorter half-lived radionuclide. It appears that the accuracy of decay correction declined not only increment of scan duration but also increment of elapsed time from a starting point of acquisition. In study using 18F, there was no big difference so it's not necessary to consider error of quantitative evaluation according to elapsed time. It's recommended to apply additional decay correction method considering decay correction the error concerning elapsed time or to set the scan duration of static image less than 5minutes corresponding 25% of half life in study using shorter half-lived radionuclide as 11C.

  • PDF