Three Cases of Atopic Dermatitis (柱枝加黃기湯으로 치료한 소아 아토피 피부염의 한방치험 3례-삼출을 주증상으로 하는 환자를 대상으로)

  • Jung Jin-yiung;Kim Yoon-bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.17 no.2
    • /
    • pp.131-139
    • /
    • 2004
  • Background: Infantile atopic dermatitis involves the face, with erythematous weepy patches. This weeping eczema has severe itching and causes eczema secondarily. Also it has a profound effect on the quality of life. Many infantile AD patient and parent suffer troubles because of weeping eczema. Objective: The purpose of this study was to evaluate the efficacy of Gyejigahwanggitang(桂枝加黃?湯) in infantile AD patient with weeping eczema. Method: I treated them with Gyejigahwanggitang(桂枝加黃?湯) for balancing YoungWi(調和榮衛). I also used acupuncture therapy.

  • PDF

Radioimmunotherapy in Head and Neck Cancer (두경부암에서 방사면역치료의 역할)

  • Choi, Ik Joon
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.12
    • /
    • pp.637-643
    • /
    • 2018
  • Radioimmunotherapy (RIT) is a therapy that takes advantage of the "cross-fire" effect of emitted radiation by radionuclides conjugated to tumor-directed monoclonal antibodies (mAb) (including those fragments) or peptides. While RIT has been successfully employed for the treatment of lymphoma, mostly with radiolabeled antibodies against CD20 [$^{90}yttrium$ ($^{90}Y$)-ibritumomab tiuxetan; $Zevalin^{(R)}$ and $^{131}iodine$ ($^{131}I)-tositumomab$; $Bexxar^{(R)}$], its use in solid tumors is more challenging, so far. Immuno-PET, a tool for tracking and quantification of mAbs with PET in vivo, is an exciting novel option to improve diagnostic imaging and guide mAb-based therapy. RIT in solid tumors including head and neck cancer may be an alternative treatment with advances in various biological, chemical, and treatment procedures, and it may help to reduce unnecessary exposure and enhance the therapeutic efficacy. Also, immuno-PET based on RIT might play an important role in cancer staging, in patients or targets selection of targeted therapeutics and in monitoring the response of targeted therapeutics as precision medicine. In this review, fundamentals of RIT/immune-PET and current knowledge of the preclinical/clinical trials in RIT for solid tumor including head and neck cancer are reviewed.

A Study of Measuring the Surface Contamination for Patient's Clothes and Bedclothes after Ablation Therapy (방사성옥소 치료환자의 환의 및 침구류에 대한 표면오염 측정에 관한 고찰)

  • Moon, Jae-Seung;Park, Dae-Seong;Kim, Su-Keun;Jeong, Hee-Il
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.3-12
    • /
    • 2008
  • Purpose: Contaminated clothes and bedclothes of patients by mouth or with excrement are produced after Radioisotope $^{131}I$ treatment. In this paper, patient's clothes and bedclothes contaminated by radioactivity measured and radioactive waste wish to calculate optimum storage period. Material and Methods: The whole area of patients' clothes and bedclothes measured 70 patients, 12 males and 58 females, who had radioisotope $^{131}I$ therapy between August 2005 and February 2006. Assuming contamination is evenly distributed, the radioscope used to measure up to social toleration level at 7 day intervals. Results: Each optimum storage period of control group of 60 case and non control group of 10 case were average $44{\pm}16$ days and $32{\pm}13$ days. Decontamination effect of surface contamination for radioactive waste was average $83.66{\pm}15.15%$. Conclusion: It is important that classify radioactive waste according to difference of surface contamination. Result of this research, handling radioactive waste in optimum storage period may be useful.

  • PDF

A Summary of Radiation Accidents in Atomic Energy Activities of Korea (우리나라의 원자력 연구 개발에 수반된 방사선 사고)

  • 이현덕;하정우
    • Nuclear Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.97-106
    • /
    • 1970
  • Radiation accidents which occured in the A.E.R.I. during last ten years are described (table 1). It seemed to the authors that some of these accidents were considered to be hazardous to man body and associated installations. This report deals with the following four major accidents involving body contamination incidents that our health physicists have been experienced. 1. Over-exposures (up to 130 rem) to the total body due to the mismanipulation in the Cobalt-60 gamma irradiation facility. 2. Floor surface contamination (up to 13 mrad/hr) and its spread out due to the mishandling of radioiodine contained in the bottle. 3. Body surface contamination and 0.36 uCi radioactivity accumulated in the thyroid gland of a worker due to the inhalation of gaseous iodine-131. 4. A void capsule due to the leakage out of the radium therapeutic source (3mg\ulcorner) These accidents were treated by definitely prompt action to protect the workers and associated installations from any radiation hazards and every possible efforts were made to confine the spread of radioactive contamination as small area as possible by means of elaborate decontamination work and monitoring.

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Long-Term Trend Analysis in Nuclear Medicine Examinations (핵의학 영상 검사의 중장기 추세 분석 - 서울 소재 일개 상급 종합병원을 중심으로 -)

  • Jung, Woo-Young;Shim, Dong-Oh;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.15-28
    • /
    • 2019
  • Purpose Nuclear medicine was initially introduced in Korea in 1969 and widely applied to treat hyperthyroidism with $^{131}I$. Also, gamma camera was adopted in 1969 in the first place and its application has been growing continually in many ways. We analyzed long-term trend in nuclear medicine examinations for the last 2 decades. The purpose of this paper is to make predictions and to set both plans and directions on the development of nuclear medicine. Materials and Methods We analyzed the performance of nuclear medicine examinations and therapies performed in Asan Medical Center from 1998 to 2017. Results Results from the last 20 years regarding Bone scan, Renal scan, MUGA scan and $^{18}F$-FPCIT, Bone Mineral Density were on a increase. And Myocardium perfusion SPECT, Thyroid scan, Lung scan were on a decrease while $^{18}F-FDG$ PET maintained on a steady course. Until 2010 there was a positive performance with the therapy but after the excessive medical care in thyroid examination performance is at status quo. Key events such as a medical strike(2000), Middle-East Respiratory Syndrome (2015) influenced the overall performance of the therapy. Conclusion In order to promote a long-term growth in nuclear medicine examination and therapy, it is inevitable to respond to the changes in current medical environment. Furthermore, it is strongly suggested to put efforts to maintain and develop new examinations and clinical indicators.

Determination of Self-Disposal date by the Analysis of Radioactive Waste Contamination for 1131I Therapy Ward (131I 치료입원실 폐기물 방사능 오염도 분석 및 자체처분가능일자 산출)

  • Kim, Gi-sub;Jung, Haijo;Park, Min-seok;Jeon, Gjin-seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.3-6
    • /
    • 2013
  • Purpose: The treatment of thyroid cancer patients was continuously increased. According to the increment of thyroid cancer patients, the establishment of iodine therapy site was also increased in each hospital. This treatment involves the administration of radioactive iodine, which will be given in the form of a capsule. Therefore, protections and managements for radioactive source pollution and radiation exposure should be necessary for radiation safety. Among the many problems, the problem of disposing the radioactive wastes was occurred. In this study, The date for self-disposal for radioactive wastes, which were contaminated in clothes, bedclothes and trash, were calculated. Materials and Methods: The number of iodine therapy ward was 15 in Korea Institute of Radiological Medical and Sciences. Recently, 8 therapy wards were operated for iodine therapy patients and others were on standby for emergency treatment ward of any radiation accidents. Radioactive wastes, which were occurred in therapy ward, were clothes, bedclothes, bath cover for patients washing water and food and drink which was leftover by patients. Each sample was hold into the marinelli beaker (clothes, bedclothes, bath covers) and 90 ml beaker (food, drink, and washing water). The activities of collected samples were measured by HpGe MCA device (Multi Channel Analysis, CANBERRA, USA) Results: The storage period for the each kind of radioactive wastes was calculated by equation of storage periods based on the measurement outcomes. The average storage period was 60 days for the case of clothes, and the maximum storage period was 93 days for patient bottoms. The average storage period and the maximum storage period for the trash were 69 days and 97 days, respectively. The leftover foods and drinks had short storage period (the average storage period was 25 days and maximum storage period was 39 days), compared with other wastes. Conclusion: The proper storage period for disposing the radioactive waste (clothes, bedclothes and bath cover) was 100 days by the regulation on self-disposal of radioactive waste. In addition, the storage period for disposing the liquid radioactive waste was 120 days. The current regulation for radioactive waste self-disposing was not suitable for the circumstances of each radioactive therapy facility. Therefore, it was necessary to reduce the leftover food and drinks by adequate table setting for patients, and improve the process and regulation for disposing the short-half life radioactive wastes.

  • PDF

Evaluation of Caregivers' Exposed Dose and Patients' External Dose Rate for Radioactive Iodine (I-131) Therapy Administration in Isolated Ward (방사성요오드(I-131) 격리병실 치료 관리를 위한 환자의 체외방사선량률과 상주 보호자의 피폭선량평가)

  • Kang, Seok-Jin;Lee, Doo-Hyeon;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.347-353
    • /
    • 2022
  • In this study, the radiation dose rate was measured by time and distance and evaluated whether radiation dose rate was suitable for domestic and international discharge criteria. In addition, the radiation dose emitted from the patient was measured with a glass dosimeter to evaluate the exposure dose if the caregiver stays in the isolated ward by placing a humanoid phantom instead of the caregiver at a distance of 1 m from the patient, on the second day of treatment. After 23 hours of isolation, the radiation dose rates at a distance of 1 m were 20.54 ± 6.21 µSv/h at 2.96 GBq administration and 27.94 ± 12.33 µSv/h at 3.70 GBq administration. The radiation dose rates at a distance of 1 m were 25.90 ± 2.21 µSv/h when 2.96 GBq was administered and 34.22 ± 10.06 µSv/h when 3.70 GBq was administered after 18 hours of isolation. However, if the isolation period is short may cause unnecessary radiation exposure to the third person. The reading of the attached dosimeter from the morning of the second day of treatment until removal was 0.01 to 0.95 mSv, which is a surface dose determined by the International Commission on Radiation Units and Measurements. And the depth dose was 0.01 to 0.99 mSv. On the second day of treatment, even if the patient caregivers stayed in the isolation ward, the exposure dose of the patient family did not exceed the effective dose limit of 5 mSv recommended by the ICRP and NCRP.

Effects of Albizziae Cortex Pharmacopuncture Extracts on the Collagenase Activity and Procollagen Synthesis in HS68 Human Fibroblasts and Tyrosinase Activity (합환피(合歡皮) 약침액(藥鍼液)의 사람 피부아세포의 콜라게나제 활성 및 프로콜라겐 합성과 티로시나제 활성에 미치는 영향)

  • Leem, Kang-Hyun
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • 목적 : 본 연구는 합환피약침액(合歡皮藥鍼液)이 사람 피부 섬유아세포의 콜라게나제 활성 및 프로콜라겐 합성에 미치는 영항과 티로시나제 활성에 미치는 효과를 측정하고자 실시하였다. 방법 : HS68 사람 정상 섬유아세포에 UVB 조사 후 합환피(合歡皮) 약침액(藥鍼液)가 type I procollagen 생성과 콜라게나제 효소활성에 미치는 효능과 티로시나제 효소활성에 미치는 효능을 평가하였다. 결과 : 합환피약침액(合歡皮藥鍼液)은 UVB 조사된 세포의 콜라게나제 효소활성을 통계적으로 유의하게 억제하였고, 티로시나제 활성을 통계적으로 유의하게 억제하였다. 그러나 티로시나제 억제활성의 정도는 미백효능으로 활용하기에 약간 약한 경향이 있었다. 결론 : 합환피약침액(合歡皮藥鍼液)의 콜라게나제 억제효능은 주름개선 약침치료에 활용이 가능할 것으로 생각된다.