• 제목/요약/키워드: $\gamma$-measurements

검색결과 321건 처리시간 0.027초

중성자선과 감마선 동시측정이 가능한 휴대용 계측시스템 개발에 관한 연구 (Development of a Portable Detection System for Simultaneous Measurements of Neutrons and Gamma Rays)

  • 김희경;홍용호;정영석;김재현;박수연
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.481-487
    • /
    • 2020
  • Radiation measurement technology has steadily improved and its usage is expanding in various industries such as nuclear medicine, security search, satellite, nondestructive testing, environmental industries and the domain of nuclear power plants (NPPs). Especially, the simultaneous measurements of gamma rays and neutrons can be even more critical for nuclear safety management of spent nuclear fuel and monitoring of the nuclear material. A semiconductor detector comprising cadmium, zinc, and tellurium (CZT) enables to detect gamma-rays due to the significant atomic weight of the elements via immediate neutron and gamma-ray detection. Semiconductor sensors might be used for nuclear safety management by monitoring nuclear materials and spent nuclear fuel with high spatial resolution as well as providing real-time measurements. We aim to introduce a portable nuclide-analysis device that enables the simultaneous measurements of neutrons and gamma rays using a CZT sensor. The detector has a high density and wide energy band gap, and thus exhibits highly sensitive physical characteristics and characteristics are required for performing neutron and gamma-ray detection. Portable nuclide-analysis device is used on NPP-decommissioning sites or the purpose of nuclear nonproliferation, it will rapidly detect the nuclear material and provide radioactive-material information. Eventually, portable nuclide-analysis device can reduce measurement time and economic costs by providing a basis for rational decision making.

Gamma Evaluation with Portal Dosimetry for Volumetric Modulated Arc Therapy and Intensity-Modulated Radiation Therapy

  • Kim, Jung-in;Choi, Chang Heon;Park, So-Yeon;An, HyunJoon;Wu, Hong-Gyun;Park, Jong Min
    • 한국의학물리학회지:의학물리
    • /
    • 제28권2호
    • /
    • pp.61-66
    • /
    • 2017
  • The aim of this study is to investigate the characteristics of portal dosimetry in comparison with the MapCHECK2 measurments. In this study, a total of 65 treatment plans including both volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) were retrospectively selected and analyzed (45 VMAT plans and 20 IMRT plans). A total of 4 types of linac models (VitalBeam, Trilogy, Clinac 21EXS, and Clianc iX) were used for the comparison between portal dosimetry and the MapCHECK2 measurements. The VMAT plans were delivered with two VitalBeam linacs (VitalBeam1 and VitalBeam2) and one Trilogy while the IMRT plans were delivered with one Clinac 21EXS and one Clinacl iX. The global gamma passing rates of portal dosimetry and the MapCHECK2 measurements were analyzed with a gamma criterion of 3%/3 mm for IMRT while those were analyzed with a gamma criterion of 2%/2 mm for VMAT. Spearman's correlation coefficients (r) were calculated between the gamma passing rates of portal dosimetry and those of the MapCHECK2 measurements. For VMAT, the gamma passing rates of portal dosimetry with the VitalBeam1, VitalBeam2, and Trilogy were $97.3%{\pm}3.5%$, $97.1%{\pm}3.4%$, and $97.5%{\pm}1.9%$, respectively. Those of the MapCHECK2 measurements were $96.8%{\pm}2.5%$, $96.3%{\pm}2.7%$, and $97.4%{\pm}1.3%$, respectively. For IMRT, the gamma passing rates of portal dosimetry with Clinac 21EXS and Clinac iX were $99.7%{\pm}0.3%$ and $99.8%{\pm}0.2%$, respectively. Those of the MapCHECK2 measurements were $96.5%{\pm}3.3%$ and $97.7%{\pm}3.2%$, respectively. Except for the result with the Trilogy, no correlations were observed between the gamma passing rates of portal dosimetry and those of the MapCHECK2 measurements. Therefore, both the MapCHECK2 measurements and portal dosimetry can be used as an alternative to each other for patient-specific QA for both IMRT and VMAT.

Using machine learning for anomaly detection on a system-on-chip under gamma radiation

  • Eduardo Weber Wachter ;Server Kasap ;Sefki Kolozali ;Xiaojun Zhai ;Shoaib Ehsan;Klaus D. McDonald-Maier
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.3985-3995
    • /
    • 2022
  • The emergence of new nanoscale technologies has imposed significant challenges to designing reliable electronic systems in radiation environments. A few types of radiation like Total Ionizing Dose (TID) can cause permanent damages on such nanoscale electronic devices, and current state-of-the-art technologies to tackle TID make use of expensive radiation-hardened devices. This paper focuses on a novel and different approach: using machine learning algorithms on consumer electronic level Field Programmable Gate Arrays (FPGAs) to tackle TID effects and monitor them to replace before they stop working. This condition has a research challenge to anticipate when the board results in a total failure due to TID effects. We observed internal measurements of FPGA boards under gamma radiation and used three different anomaly detection machine learning (ML) algorithms to detect anomalies in the sensor measurements in a gamma-radiated environment. The statistical results show a highly significant relationship between the gamma radiation exposure levels and the board measurements. Moreover, our anomaly detection results have shown that a One-Class SVM with Radial Basis Function Kernel has an average recall score of 0.95. Also, all anomalies can be detected before the boards are entirely inoperative, i.e. voltages drop to zero and confirmed with a sanity check.

Development of a DDA+PGA-combined non-destructive active interrogation system in "Active-N"

  • Kazuyoshi Furutaka;Akira Ohzu;Yosuke Toh
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4002-4018
    • /
    • 2023
  • An integrated neutron interrogation system has been developed for non-destructive assay of highly-radioactive special nuclear materials, to accumulate knowledge of the method through developing and using it. The system combines a differential die-away (DDA) measurement system for the quantification of nuclear materials and a prompt gamma-ray analysis (PGA) system for the detection of neutron poisons which disturb the DDA measurements; a common D-T neutron generator is used. A special care has been taken for the selection of materials to reduce the background gamma rays produced by the interrogation neutrons. A series of measurements were performed to test the basic performance of the system. The results show that the DDA system can quantify plutonium of as small as 20 mg and it is not affected by intense neutron background up to 1.57 × 107 s-1 and gamma ray of 4.43 × 1010 s-1. The gamma-ray background counting rate at the PGA detector was reduced down to 3.9 × 103 s-1 even with the use of the D-T neutron generator. The test measurements show that the PGA system is capable of detecting 0.783 g of boron and about 86.8 g of gadolinium in 30 min.

Silicon P-N Junction Diode에 대한 X-Ray 및 Gamma-Ray 의 Dose Ratec 측정 (Measurements of X-Ray and Gamma Ray Dosse Rate by the Silicon P-N Junction Diode)

  • 정만영;김덕진
    • 전기의세계
    • /
    • 제13권3호
    • /
    • pp.13-20
    • /
    • 1964
  • The measurements of X-ray and Gamma-ray Dose Rate have been successfully made by measuring the short circuit current of the Silicon P-N Junction Diode being irradiated. The short circuit current flows when a silicon P-N Junction Diode is irradiated by X-ray of Gammaray radiations due to photovoltaic effect. A brief analysis is given in order to verify the proportionality of a short circuit current to the Dose Rate. Using this method, measurements of X-ray Dose Rate were carried out in the range of 0.05-1600 r/m successfully. The calibration was made by comparing with Victoreen condenser r-meter. Some advantages in this Dose Rate meter over a condenser r-meter were found. One can measure a continous variation of X-ray Dose Rate with this rate meter at the control console of X-ray device.

  • PDF

Calculation and measurement of Al prompt capture gammas above water in a pool-type reactor

  • Czakoj, Tomas;Kostal, Michal;Losa, Evzen;Matej, Zdenek;Simon, Jan;Mravec, Filip;Cvachovec, Frantisek
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3824-3832
    • /
    • 2022
  • Prompt capture gammas are an important part of the fission reactor gamma field. Because some of the structural materials after neutron capture can emit photons with high energies forming the dominant component of the gamma spectrum in the high energy region, the following study of the high energy capture gamma was carried out. High energy gamma radiation may play a major role in areas of the radiation sciences as reactor dosimetry. The HPGe measurements and calculations of the high-energy aluminum capture gamma were performed at two moderator levels in the VR-1 pool-type reactor. The result comparison for nominal levels was within two sigma uncertainties for the major 7.724 MeV peak. A larger discrepancy of 60% was found for the 7.693 MeV peak. The spectra were also measured using a stilbene detector, and a good agreement between HPGe and stilbene was observed. This confirms the validity of stilbene measurements of gamma flux. Additionally, agreement of the wide peak measurement in 7-9.2 MeV by stilbene detector shows the possibility of using the organic scintillators as an independent power monitor. This fact is valid in these reactor types because power is proportional to the thermal neutron flux, which is also proportional to the production of capture gammas forming the wide peak.

Full spectrum estimation of helicopter background and cosmic gamma-ray contribution for airborne measurements

  • Lukas Kotik;Marcel Ohera
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1052-1060
    • /
    • 2023
  • The airborne radiation monitoring has been used in geophysics for more than forty years and now it also has its important role in emergency monitoring. The aircraft background and the cosmic gamma-rays contribute to the measured gamma spectrum on the aircraft board. This adverse effect should be eliminated before the data processing. The paper describes two semiparametric methods to estimate the full spectrum aircraft background and cosmic gamma-ray contribution from spectra measured at altitudes where terrestrial contribution is negligible. The methods only assume to know possible peak positions in spectra and their full width at half maximum, that can be easily obtained e.g. from terrestrial measurement. The methods were applied to real experimental data acquired on Mi-17 and Bell 412 helicopter boards. The IRIS airborne gamma-ray spectrometer, with 4×4 L NaI(Tl) crystals, produced by Pico Envirotec Inc., Canada, was used on helicopters' boards. To obtain valid estimate of the aircraft background and the cosmic contribution, the measurements over sea and large water areas were carried out. However, the satisfactory results over inland were also achieved comparing with those acquired over large water areas.

갑산층 석회암지역에서의 코어물성과 검층물성 비교 (Comparison of Physical Properties obtained from Geophysical Well Log and Core Property Measurements in Gabsan Formation)

  • 김영화;김기주
    • 지질공학
    • /
    • 제9권3호
    • /
    • pp.253-265
    • /
    • 1999
  • 충청북도 제천 지역에 있는 갑산층 퇴적암을 대상으로 지구물리검층과 실내 코어물성 측정에 의한 물성 반응 특성을 연구하였다. 자연감마와 전기비저항 및 밀도를 대상으로 하여 지구물리검층과 실내 코어물성 사이에 나타나는 유사성과 차이점을 비교하는데 초점이 모아졌으며 특히 물리검층과 실내 코어물성 사이에 나타나는 차이점 분석 과정을 통하여 검층밀도 결정에 있어서 자연감마의 영향을 분석하였다. 자연감마의 영향 보정에 의하여 두 물성간의 상관성이 개선되고 검층해석 결과에서 신뢰도가 크게 향상되었다. 물성 값중에서는 갑산층 셰일의 밀도가 주변의 치밀질 석회암보다도 높게 나타나고 있음이 주목되었다.

  • PDF

Co-60과 Cs-134의 연발감마선에 대한 방향 및 편극상관 측정 (Measurements of the Direction and Polarization Correlation for Cascade Gamma-rays of Co-60 and Cs-134)

  • Hyung-Ju Woo;Kie-Hyung Chung;Hae-Ill Bak
    • Nuclear Engineering and Technology
    • /
    • 제14권2호
    • /
    • pp.64-69
    • /
    • 1982
  • 동시섬광분석기를 써서, 각도범위 90$^{\circ}$에서 180$^{\circ}$에 대하여, Co-60 및 Cs-134 감마선의 방향상관을 측정하였다. 그리고, 방향-편극상관의 측정에는 컴프턴산란효과를 응용한 감마선 편광분광기를 병용하였다. 이론적인 배경과 더불어 실험방법이 기술되었으며, 측정값이 이론적인 개산치와 일치함을 보이기위해 실험결과를 도식적으로 나타내었다.

  • PDF

Detection of voluminous gamma-ray source with a collimation beam geometry and comparison with peak efficiency calculations of EXVol

  • Kang, M.Y.;Sun, G.M.;Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2601-2606
    • /
    • 2020
  • In this study, we expanded the performance of the existing EXVol code and performed empirical experiments and calculations. A high-resolution gamma spectroscopy system was constructed, and a standard point source and a standard volume source were measured with an HPGe detector with 43.1% relative efficiency. EXVol was verified by quantitative comparison of the detection efficiencies determined by measurements and calculations. To introduce the concept of the detector scanning that occurs in the actual measurement into the EXVol code, a collimator was placed between the source and detector. The detection efficiency was determined in the asymmetric arrangement of the source and detector with a collimator. A collimator made of lead with a diameter of 15 mm and a thickness of 50 mm was installed between the source and the detector to determine the detection efficiency at a specific location. The calculation result was contour plotted so that the distribution of detection efficiency could be visually confirmed. The relative deviation between the measurements and calculations for the coaxial and asymmetric structures was 10%, and that for the collimation structure was 20%. The results of this study can be applied to research using γ-ray measurements.