• Title/Summary/Keyword: $\gamma$-Irradiation

Search Result 1,625, Processing Time 0.032 seconds

Microbiological and Mutagenical Safety Evaluation of Gamma Irradiated Ready-to-Eat Foods of Animal Origin (즉석식품 제조를 위한 육가공제품의 감마선 조사에 따른 미생물 및 유전독성학적 안전성 평가)

  • Lee Na-Young;Jo Cheorun;Kang Ho-Jin;Hong Sang-Pill;Kim Young-Ho;Lee Kyong-Haeng;Byun Myung-Woo
    • Food Science of Animal Resources
    • /
    • v.25 no.1
    • /
    • pp.13-19
    • /
    • 2005
  • The radio-sensitivity of pathogens and the effect of irradiation on microbiologican safety and mutagenicity of meat products such as seasoned and cooked beef and ham were investigated. Samples were radiation-sterilized and inoculated at 10/sup 7/ cfu/g with each of the four pathogens including Salmonella typhimurium, Escherichia coli, Staphylcoccus aureus, and Listeria ivanovii. No viable cells of pathogens were observed in the sample irradiated with 3 kGy. The D/sub 10/ value of inoculated pathogens in seasoned and cooked beef and ham were 0.24∼0.48 and 0.39∼0.45, respectively. Results of Ames test performed with non-irradiated and irradiated seasoned and cooked beef and ham were both negative at the level of 625, 1,250, 2,500, 50,000, and! 10,000 ㎍ sample/plate, respectively. Results indicate that low dose (2∼3 kGy) irradiation is effective to ensure safety for seasoned and cooked beef and ham with toxicological wholesomeness.

Detection Characteristics of TL, ESR and DNA Comet for Irradiated Peanuts by Origins (TL, ESR및 DNA Comet분석에 의한 원산지별 땅콩의 방사선 조사 검지 특성)

  • 이은영;정재영;조덕조;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.6
    • /
    • pp.1076-1081
    • /
    • 2001
  • Gamma-irradiated peanuts, Korean and Chinese origins, were investigated on detection properties by thermoluminescence (TL), electron spin resonance (ESR), and DNA comet assay (single cell gel electrophoresis). TL measurement showed that the non-irradiated sample revealed a glow curve with low intensity at about 25$0^{\circ}C$, while the irradiated samples showed higher intensity around at 18$0^{\circ}C$. TL ratio (TL$_1$/TL$_2$) of area for TL$_1$ glow curve to TL$_2$ was below 0.05 for the non-irradiated sample and 0.2 or more for the irradiated ones, thus identifying each other. ESR spectroscopy for the irradiated peanuts using outer skin showed negligible signals induced by irradiation, indicating ESR is little applicable to the detection of irradiated peanuts. In DNA comet assay, the non-sample had no or very short tails, whereas the irradiated samples revealed the cells with long tails. Significance in the increase of their lengths depending on irradiation dose (r=0.761/Korean, r=0.768/Chinese) was also found. There was no remarkable difference in detection properties by origins of samples in all determinations, It is concluded that TL analysis or DNA comet assay is suitable for detection of irradiated peanuts and a combined method is recommendable for enhancing the reliability of detection results.

  • PDF

The Influence of E-beam Irradiation on POLY(ETHER-BLOCK-AMIDE) (PEBA, Pebax) (전자 빔 조사후 PEBA (Poly Ether Block Amide)의 구조 및 기계적 특성 변화)

  • Shin, Sukyoung;Cho, SangGyu
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.205-209
    • /
    • 2014
  • Medical polymers require sterilization and must be able to maintain material properties for a specified shelf life. Sterilization can be achieved by using gamma or e-beam exposure. In this study, accelerated aging tests of poly(ether-block-amide) (PEBA) copolymer samples is presented. PEBA copolymer samples with different polyether content that result in Shore hardness of 35D to 72D, were sterilized using e-beam radiation followed by accelerated aging at $55^{\circ}C$. E-beam sterilization effect on molecular weight and mechanical property has performed and analyzed. The average molecular weight significantly reduced as a result of ageing. The enlarged proportion of low molecular weight chains in the aged samples is consistent with the generation of degradation products produced by oxidative chain scission. Also E-beam materials have shown decreased tensile strength and elongation. Overall, this study demonstrated that the medical grade PEBA was significantly affected by radiation exposure over aging time, particularly at high irradiation doses. For medical use in case of radiation sterilization required, it is recommended to avoid Pebax material. If Pebax material must be in use for medical device, recommend to use alternate sterilization method such as Ethylene Oxide sterilization.

Physicochemical Quality and Detection Properties of Irradiated Powdered-Soups (감마선 조사된 분말수프의 이화학적 품질과 조사여부 판별특성)

  • Kwak, Ji-Young;An, Yeoung-Eun;Jung, Bo-Yun;Kwon, Joong-Ho
    • Current Research on Agriculture and Life Sciences
    • /
    • v.30 no.2
    • /
    • pp.82-89
    • /
    • 2012
  • Commercial powdered soups, such as potato soup(PS), corn soup(CS), and chicken-herb soup(CHS), were gamma-irradiated at 0, 1, 5 and 10 kGy and subjected to physicochemical evaluation and identification trials by analyzing photostimulated luminescence(PSL), electron spin resonance(ESR), and thermoluminescence(TL). The changes in moisture content and pH of soup samples were negligible upon irradiation. The Hunter's color determinations showed that lightness (L value) decreased and yellowness (b value) increased as the irradiation dose increased in PS sample. The viscosity of irradiated samples was reduced in the order of PS, CS and CHS. The analyses of PSL, ESR and TL were applicable to the identification of irradiated powdered-soups at more than 1 kGy by detecting PSL photon counts/60 sec(over 5000), radiation-induced multicomponents-ESR signal, and typical TL glow curve at $150-250^{\circ}C$.

  • PDF

Experimental Study for the Teratogenic Effect of Gamma-ray on the Heart of Chick Embryo (계태에서 감마선 조사에 의한 심장기형 발생에 관한 실험적 연구)

  • Jo, Yong Whan;Kim, Nam Su;Moon, Sung Yup;Yum, Myeng Gul;Kim, Sung Hoon;Chun, Ha Chung;Kim, Yong Joo;Lee, Hahng
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.6
    • /
    • pp.554-560
    • /
    • 2003
  • Purpose : To investigate the teratogenic effect of gamma-ray on the heart of chick embryo. Methods : 50 rad, 100 rad, 150 rad, 200 rad, 250 rad, and 300 rad of gamma-ray were used to irradiate three days old chick embryos. The control group was not irradiated. After three weeks, the embryos were sacrificed and examined for cardiovascular malformation. Results : The survival rate of the gamma-ray irradiated group was significantly lower than that of the control group(33.3-63.3% vs 76.4%, P=0.001). The cardiac malformation rate of the experimental group was 11.0%. In the control group, no congenital cardiac malformations were observed. The experimental groups had a significantly higher malformation rate(P=0.001). The types of malformation were ventricular septal defect, tricuspid atresia, Ebstein anomaly and aortic arch anomaly. In the gamma-ray irradiated group, the cardiac malformations were : 14 small ventricular septal defects (VSDs), five large VSDs, two tricuspid atresias, and one Ebstein anomaly. The higher the dose of radiation applied, the higher the incidence of cardiac malformation was noted. Conclusion : Gamma-ray irradiation of 3 days old chick embryos increased the rate of death and the rate of cardiac malformation significantly.

Evaluation of Tissue Inhomogeneity for Gamma-knife Radiosurgery Using Film Dosimetry (감마 나이프 방사선 수술시 필름 선량 측정에 의한 조직 불균일성에 대한 연구)

  • Cho, Heung-Lae;Shon, Seung-Chang;Shu, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.325-335
    • /
    • 1998
  • Purpose : Since the mid cranial fossa is composed of various thickness of bone, the tissue inhomogeneity caused by bone would produce dose attenuation in cobalt-60 gamma knife irradiation. The correction factor for bone attenuation of cobalt-60 which is used for gamma knife source is -3.5$\%$. More importantly, nearly all the radiosurgery treatment planning systems assume a treatment volume of unit density: any perturbation due to tissue inhomogeneity is neglected, This study was performed to confirm the bone attenuation in mid cranial fossa using gamma knife. Materials and Methods : Computed tomography was performed after Leksell stereotactic frame had been liked to the Alderson Rando Phantom (human phantom) skull area. Kodak X-omat V film was inserted into two sites of pituitary adenoma point and acoustic neurinoma point, and irradiated by gamma knife with 14mm and 18mm collimator. An automatic scanning densitometer with a 1mm aperture is used to measure the dose profile along the x and y axis. Results : Isodose curve constriction in mid cranial fossa is observed with various ranges. Pituitary tumor point is greater than acoustic neurinoma point (0.2-3.0 mm vs 0.1-1.3 mm) and generally 14 mm collimator is greater than 18mm collimator (0.4-3.0 mm vs. 0.2-2.2 mm) Even though the isodose constriction is found, constriction of 50$\%$ isodose curve which is used for treatment reference line does not exceed 1 mm. This range is too small to influence the treatment planning and treatment results. Conclusion : Radiosurgery planning system of gamma knife does not show significant error to be corrected without consideration of bone attenuation.

  • PDF

Effects of ionizing and ultraviolet radiation on microbial mutation and DNA damage (전리방사선 및 자외선의 미생물 돌연변이와 DNA 손상에 대한 영향)

  • Nam, Ji-Hyun;Shin, Ji-Hye;Lee, Jung-Yun;Lee, Dong-Hun
    • Korean Journal of Microbiology
    • /
    • v.53 no.1
    • /
    • pp.20-28
    • /
    • 2017
  • Physical sterilization methods using ultraviolet radiation and ionizing radiation such as gamma ray and electron beam are applied in various industry fields due to disinfection effects and economic efficiency but may also cause microbial mutation. In this research, Salmonella enterica and Escherichia coli strains were treated with ionizing and ultraviolet radiation and their survival rate, mutation rate, and DNA damage were studied to evaluate the genetic safety. The survival rate of the strains decreased drastically as the irradiation dose of ultraviolet ray, gamma ray, and electron beam increased, and over 90% of the strain was exterminated at a dosage of $0.40{\sim}25.06mJ/cm^3$, 0.11~0.22 kGy, 0.14~0.53 kGy respectively. In SOS / umu-test, genotoxicity causing DNA damage was identified in all samples. In Ames test, back-mutation rate increased to $3.82{\times}10^{-4}$ and $9.84{\times}10^{-6}$ respectively when exposed to ultraviolet ray and gamma ray. At exposure to ultraviolet ray, gamma ray, and electron beam with dosage of over 99.99% extinction rate of S. enterica TA100, back-mutation rate increased 347 times, 220 times, 0.6 times respectively to the spontaneous back-mutation rate. Rifampicin resistance mutation rate of E. coli CSH100 exposed to ultraviolet ray, gamma ray, and electron beam was $2.46{\times}10^{-6}$, $1.66{\times}10^{-6}$, $4.12{\times}10^{-7}$ respectively. Therefore, gamma radiation is effective in microorganism control from the perspective of disinfection and electron beam has the advantage of sterilizing with little DNA damage and bacterial mutation.

Preparation and Characterization of Poly(styrenesulfonic acid)-grafted Fluoropolymer Membrane for Direct Methanol Fuel Cell

  • Choi, Jae-Hak;Kang, Phil-Hyun;Lim, Youn-Mook;Sohn, Joon-Yong;Shin, Jun-Hwa;Jung, Chan-Hee;Jeun, Joon-Pyo;Nho, Young-Chang
    • Korean Membrane Journal
    • /
    • v.9 no.1
    • /
    • pp.52-56
    • /
    • 2007
  • A proton exchange membrane was prepared by ${\gamma}-irradiation-induced$ grafting of styrene into poly(tetrafluoro-ethylene-co-perfluoropropyl vinyl ether) (PFA) and subsequent sulfonation reaction. The degree of grafting (DOG) increased with an increase in the absorbed dose. The prepared membranes showed high ion exchange capacity reaching 3.0 meq/g, which exceeded the performance of commercially available perfluorosulfonic acid membranes such as Nafion. The proton conductivity of PFA-g-PSSA membrane increased with the DOG and reached 0.17 S/cm for the highest sample at room temperature. The DMFC performance of the prepared membranes with 50% DOG was comparable to that of Nafion membrane.

Functionalization of polyethylene by graft copolymerization for separation processes

  • Kaur, Inderjeet;Gupta, Nitika;Kumari, Vandna
    • Advances in materials Research
    • /
    • v.2 no.1
    • /
    • pp.15-36
    • /
    • 2013
  • Incorporation of polar functional moieties into polyethylene (PE) film has been achieved by graft copolymerization of polar monomers such as methacrylic acid (MAAc) and acrylamide (AAm) on to PE film, preirradiated with ${\gamma}$-rays from $^{60}Co$ source, using benzoyl peroxide (BPO) as initiator in aqueous medium. Percentage of grafting of MAAc and AAm was determined as a function of irradiation dose, monomer and initiator concentration, temperature, reaction time and amount of water. Maximum percentage of grafting of MAAc (1453%) and AAm (21.28%) was obtained at [MAAc] = $235.3{\times}10^{-2}$ mol/L, [AAm] = $23.4{\times}10^{-2}$ mol/L, [BPO] = $5.5{\times}10^{-2}$ mol/L and $16.5{\times}10^{-2}$ mol/L at $80^{\circ}C$, $90^{\circ}C$ in 180 min and 90 min respectively. The grafted PE films were characterized by FTIR, Thermogravimetric analysis (TGA) Scanning Electron Micrography (SEM) and X-ray diffraction methods. Some selective properties of grafted films such as swelling behavior, ion and metal uptake have been carried out. The biodegradation studies of the grafted PE films have also been investigated. The grafted films developed superior swelling behavior with maximum swelling (480%) in water as compared to pristine PE (13.55%), better thermal stability and ion and metal uptake studies showed promising results that can be effectively used for desalination of brackish water and separation of metals from the industrial effluents.

Investigation on glass transition temperature of low density polyethylene by the characteristics of temperature dependent linear expansion (선팽창 온도특성에 의한 저밀도 폴리에틸렌의 유리 천이온도에 대한 고찰)

  • 김봉흡;강도열;김재환
    • 전기의세계
    • /
    • v.30 no.7
    • /
    • pp.441-447
    • /
    • 1981
  • As a preceeding work for the study on dielectric characterstics of a kind of low density polyethylene introduced morphological change by mechanical method, glass transition temperature which is regarded as a macroscopic aspect for relaxation of molecular chain segments has been observed by means of temperature dependent dilatometric measurement. The origina specimen clearly shows two knees which correspond to two peaks (.gamma. and .betha. peak) in the intenal friction measurement, suggesting the existence of separated glass transition temperatures at 150.deg.k and 260.deg.k respectively. On the specimen irradiated to 100 Mrad both glass transition temperatures tend to shift towards high temperature sides because of crosslinking by irradiation. furthemore an evidence can be seen that radiation effect, even in amorphous phase, is also slelctive depending on slight morphological differences. The specimen extended to four times in length shows a peculiar nature such as negative linear thermal expansion coefficient increasing with temperature between 220.deg.k and ambient temperature and that this fact is interpreted by considering that c axis of the lattice aligns along the extended direction by drawing, further c axis inherently possesses the characteristics of negative linear thermal expansion coefficient. For the observations that the relatively small positive linear expansion on the specimen extended to ca. two times as well as the part below 220.deg.k of the specimen extended to four times, it is considered for the reason of the facts that the incompletely oriented region indicated as the middle part of Peterlin's model tends to restore partially to orginal arrangement-a kind of phase transition-as increasing with temperature.

  • PDF