• Title/Summary/Keyword: $[^{18}F]F_2$

Search Result 3,009, Processing Time 0.037 seconds

A Study on the Usefulness of Auto Dispenser and Optimized Dispensing Method (방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰)

  • Lee, JeoungEun;Kim, Hosung;Ryu, Jaekwang;Jung, Wooyoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.59-66
    • /
    • 2013
  • Purpose: Recently, there is an increase of the number of hospitals using auto dispenser to reduce occupational radiation exposure when drawing up of the $^{18}F-FDG$ dose (5.18 MBq/kg) in a syringe from the dramatic high activity of $^{18}F-FDG$ multidose vial. The aim of this study is to confirm that using auto dispenser actually reduces the radiation exposure for technologists. Also we analyzed the reproducibility of auto dispenser to find optimized dispensing method for the device. Materials and Methods: We conducted three experiments. Comparison of radiation exposure on chest and hands: The chest and hands exposure dose received by technologists during the injection were measured by electronic personal dosimeter (EPD) and ring TLD respectively. Reproducibility of dispensed volume: We draw up the normal saline into 5 and 2 mL syringe using auto dispenser by changing the volume from 1 to 15 mm for 5 times in the same setting of the volume. The weight of 5 normal saline dispensed from the device at same volume was measured using micro balance and calculated standard deviation and coefficient of variation. Reproducibility of dispensed radioactivity: We dispensed 362.6 $MBq{\pm}10%$ of $^{18}F-FDG$ in 5 and 2 mL syringes from the multidose vial of different specific activity. In the same setting of volume, we repeated dispensing for 4 times and compared standard deviation and coefficient of variation of radioactivity between 5 syringes. Results: There was significant difference in the average of chest exposure dose according to the dispensing methods (P<0.05). Also, when dispensing $^{18}F-FDG$ in manual method, exposure dose was 11.5 times higher in right hand and 4.8 times higher in left hand than in auto method. In the result of reproducibility of dispensed volume, standard deviation and coefficient of variation shows decline as the dispensing volume increases. As a result of reproducibility of dispensed radioactivity, standard deviation and coefficient of variation increases as the specific activity increases. Conclusion: We approved that the occupational radiation exposure dose of technologists were reduced when dispensing $^{18}F-FDG$ using auto dose dispenser. Secondly, using small syringes helps to increase reproducibility of auto dose dispense. And also, if you lower the specific activity of $^{18}F-FDG$ in multidose vial below 915-1,020 MBq/mL, you can use auto dispenser more effectively keeping the coefficient of variation lower than 10%.

  • PDF

A Construction of Integrated Binding Service of The Selected Objects Considering Loads in Wide-Area Object Computing Environments (광역 객체 컴퓨팅 환경에서 부하를 고려한 선정된 객체의 통합 바인딩 서비스의 구축)

  • Kang, Myung-Suk;Jeong, Chang-Won;Joo, Su-Chong
    • Annual Conference of KIPS
    • /
    • 2002.11b
    • /
    • pp.1487-1490
    • /
    • 2002
  • 최근 분산 컴퓨팅 환경은 급진적으로 광역화되고, 이질적이며, 연합형태의 광역 시스템 구조로 변화하고 있다. 이러한 환경은 네트워크상에 광범위한 서비스를 제공하는 통신 네트워크 기반에서 구현된 수많은 객체로 구성된다. 더욱, 지구상에 존재하는 모든 객체들은 이름이나 속성에 의해 중복된 특성을 갖는다. 이러한 같은 특성을 갖는 객체들은 중복 객체로 정의된다. 그러나 기존의 네이밍이나 트레이딩 메커니즘은 독립적인 위치 투명성이 결여로 중복된 객체들의 바인딩 서비스 지원이 불가능하다. 서로 다른 시스템 상에 존재하는 중복된 객체들이 동일한 서비스를 제공한다면, 각 시스템의 부하를 고려하여 클라이언트의 요청을 분산시킬 수 있다. 이러한 이유로 본 논문에서는 광역 컴퓨팅 환경에서 중복된 객체들의 위치 관리뿐만 아니라 시스템들간의 부하 균형화를 유지하기 위해서 최소부하를 갖는 시스템에 위치한 객체의 선정하여 동적 바인딩 서비스를 제공할 수 있는 새로운 모델을 설계하고 구현하였다. 이 모델은 네이밍 및 트래이딩 기능을 통합한 서비스에 의해 중복된 객체들에 대한 단일 객체 핸들을 얻는 부분과, 얻어진 객체핸들을 사용하여 위치 서비스에 의해 하나 이상의 컨택 주소를 얻는 부분으로 구성하였다. 주어진 모델로부터, 우리는 Naming/Trading 서비스와 위치 서비스에 의한 전체 바인딩 메커니즘의 처리과정을 나타내고, 통합 바인딩 서비스의 구성요소들에 대만 구조를 상세하게 기술하였다. 끝으로 우리의 모델을 구현하기 위해, 윈도우 운영체제와 Solaris 2.5/2.7에서 사용되는 CORBA 사양을 따르는 VisBroker 4.1과 자바 언어, SQL Server 2000 그리고 LSF를 이용하였다. 그리고 구현 환경과 구성요소에 대한 수행 화면을 보였다.ool)을 사용하더라도 단순 다중 쓰레드 모델보다 더 많은 수의 클라이언트를 수용할 수 있는 장점이 있다. 이러한 결과를 바탕으로 본 연구팀에서 수행중인 MoIM-Messge서버의 네트워크 모듈로 다중 쓰레드 소켓폴링 모델을 적용하였다.n rate compared with conventional face recognition algorithms. 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되

  • PDF

A Study of Stress on the Family Caregivers for the Hospitalized Elderly (입원 노인을 돌보는 가족원의 스트레스에 관한 연구)

  • Kim Kang-MiJa
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.3 no.2
    • /
    • pp.247-258
    • /
    • 1996
  • This study explored the variables to influence the stress of the family caregivers providing care for the hospitalized elderly The subjects for this study were 104 family caregivers selected from the caregivers in the in patient departments of two major medical centers in Jeonju city. Data were collected from December 18th to 27th, 1995 using a Liker Scale Questionaire and interview. Data analyses included percentage, mean, standard deviation, t and F-test. Results were following : 1. The mean of this sample is 21.48, and the standard deviation is ${\pm}5.64$ in the perceived stress. The major variables to influence on the stress of caregivere for the hospitalized elderly were the stay (16-24hrs/day) in hospital(F=7.99, p=0.006), no other helpers(t=-2.56, P=.012), percieving severely on illness(F=3.90, P=.0232) perceiving moderately on physical health status(F=6.20, P=.0029). 2. Regarding the perceived social support of the family caregivers, the higher support the group perceived the lower stress(F=3.54, P=.0326).

  • PDF

Potential Utility of FDG PET-CT as a Non-invasive Tool for Monitoring Local Immune Responses

  • Lee, Seungho;Choi, Seohee;Kim, Sang Yong;Yun, Mi Jin;Kim, Hyoung-Il
    • Journal of Gastric Cancer
    • /
    • v.17 no.4
    • /
    • pp.384-393
    • /
    • 2017
  • Purpose: The tumor microenvironment is known to be associated with the metabolic activity of cancer cells and local immune reactions. We hypothesized that glucose metabolism measured by 2-deoxy-2-($^{18}F$)fluoro-D-glucose ($^{18}F-FDG$) positron emission tomography (PET)-computed tomography (CT) ($^{18}F-FDG$ PET-CT) would be associated with local immune responses evaluated according to the presence of tumor infiltrating lymphocytes (TILs). Materials and Methods: We retrospectively reviewed 56 patients who underwent $^{18}F-FDG$ PET-CT prior to gastrectomy. In resected tumor specimens, TIL subsets, including cluster of differentiation (CD) 3, CD4, CD8, Forkhead box P3 (Foxp3), and granzyme B, were subjected to immunohistochemical analysis. The prognostic nutritional index (PNI) was calculated as: ($10{\times}serum$ albumin value)+($0.005{\times}peripheral$ lymphocyte counts). Additionally, the maximum standard uptake value ($SUV_{max}$) was calculated to evaluate the metabolic activity of cancer cells. Results: The $SUV_{max}$ was positively correlated with larger tumor size (R=0.293; P=0.029) and negatively correlated with PNI (R=-0.407; P=0.002). A higher $SUV_{max}$ showed a marginal association with higher CD3 (+) T lymphocyte counts (R=0.227; P=0.092) and a significant association with higher Foxp3 (+) T lymphocyte counts (R=0.431; P=0.009). No other clinicopathological characteristics were associated with $SUV_{max}$ or TILs. Survival analysis, however, indicated that neither $SUV_{max}$ nor Foxp3 held prognostic significance. Conclusions: FDG uptake on PET-CT could be associated with TILs, especially regulatory T cells, in gastric cancer. This finding may suggest that PET-CT could be of use as a non-invasive tool for monitoring the tumor microenvironment in patients with gastric cancer.

Performance of pre-treatment 18F-fluorodeoxyglucose positron emission tomography/computed tomography for detecting metastasis in ovarian cancer: a systematic review and meta-analysis

  • Han, Sangwon;Woo, Sungmin;Suh, Chong Hyun;Lee, Jong Jin
    • Journal of Gynecologic Oncology
    • /
    • v.29 no.6
    • /
    • pp.98.1-98.13
    • /
    • 2018
  • Objective: We describe a systematic review and meta-analysis of the performance of ${18}F$-fluorodeoxyglucose ($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) for detecting metastasis in ovarian cancer. Methods: MEDLINE and Embase were searched for diagnostic accuracy studies that used $^{18}F-FDG$ PET or PET/CT for pre-treatment staging, using surgical findings as the reference standard. Sensitivities and specificities were pooled and plotted in a hierarchic summary receiver operating characteristic plot. Potential causes of heterogeneity were explored through sensitivity analyses. Results: Eight studies with 594 patients were included. The overall pooled sensitivity and specificity for metastasis were 0.72 (95% confidence interval [CI]=0.61-0.81) and 0.93 (95% CI=0.85-0.97), respectively. There was considerable heterogeneity in sensitivity ($I^2=97.57%$) and specificity ($I^2=96.74%$). In sensitivity analyses, studies that used laparotomy as the reference standard showed significantly higher sensitivity and specificity (0.77; 95% CI=0.67-0.87 and 0.96; 95% CI=0.92-0.99, respectively) than those including diagnostic laparoscopy (0.62; 95% CI=0.46-0.77 and 0.84; 95% CI=0.69-0.99, respectively). Higher specificity was shown in studies that confirmed surgical findings by pathologic evaluation (0.95; 95% CI=0.90-0.99) than in a study without pathologic confirmation (0.69; 95% CI=0.24-1.00). Studies with a lower prevalence of the FDG-avid subtype showed higher specificity (0.97; 95% CI=0.94-1.00) than those with a greater prevalence (0.89; 95% CI=0.80-0.97). Conclusion: Pre-treatment $^{18}F-FDG$ PET/CT shows moderate sensitivity and high specificity for detecting metastasis in ovarian cancer. With its low false-positive rate, it can help select surgical approaches or alternative treatment options.

Luminescence characterization of $EU^{3+}$ and $Bi^{3+}$ co-doped in ${Y_2}{SiO_5}$ red emitting phosphor by solid state reaction method (고상 반응법으로 합성한 ${Y_2}{SiO_5}:\;EU^{3+}$, $Bi^{3+}$ 적색 형광체의 발광 특성)

  • Moon, J.W.;Song, Y.H.;Park, W.J.;Yoon, D.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.1
    • /
    • pp.15-18
    • /
    • 2009
  • To enhance near UV-visible absorption region and to applied phosphor convert-white LEOs (PC-WLEDs), a red phosphor composed of ${Y_2}{SiO_5}:\;EU^{3+}$, $Bi^{3+}$ compounds was prepared by the conventional solid-state reaction. The photoluminescence (PL) shown that samples were excited by near UV light 395 nm for measurement of PL spectra. Emission spectra of samples have shown red emissions at 612 nm ($^5D_0{\to}^7F_2$). The enhanced near $UV{\sim}$ visible excitation spectrum with a broad band centered at 258 nm and 282 nm originated in the transitions toward the charge transfer state (CTS) due to the $Eu^{3+}-Bi^{3+}-O^{2-}$ interaction. The other excitation band at $350\;nm{\sim}480\;nm$, corresponding to the transitions $^7F_0{\to}^5L_9$ (364 nm), $^7F_0{\to}^5G_3$ (381 nm), $^7F_0{\to}^5L_6$ (395 nm), $^7F_0{\to}^5D_3$, (415 nm) and $^7F_0{\to}^5D_2$ (466 nm), occurred due to enhanced the f-f transition increasing $Bi^{3+}$ and $Eu^{3+}$ ions. The PL intensity increased with increased as concentration of $Bi^{3+}$ and the emission intensity becomes with a maximum at 0.125 mol.

Analysis of Residual Solvents of [F-18]FDG Using Gas Chromatography (기체크로마토그래프법을 이용한 [F-18]FDG의 잔류용매 분석)

  • Kim, Dong-Il;Lee, Il-Jung;Kim, Shi-Hwal;Chi, Yong-Gi;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.26-29
    • /
    • 2011
  • Purpose: The general test method of the Korean Pharmacopeia specifies the test method on the clauses of quality control after manufacturing. According to KFDA Guidance for Medicines, standards of residual solvents regulates the maximum permissible dose of acetonitrile as 400 ppm, ethanol as 5,000 ppm, and acetic acid as 5,000 ppm. This study aims at identifying the type of resiual solvents in the final [F-18]FDG vial of an automatic synthesizer and measure its residual quantity. Materials and Methods: The center carried out residual solvents test of [F-18]FDG injection using Agilent Technologies 7890A with a Flame Ionization Detector. The column of Agilent Technologies 7890A used in measuring of residual solvents was CP WAX column ($30m{\times}0.53mm{\times}1.0{\mu}m$) and analysis condition was split mode 1:1 at the initial temperature $70^{\circ}C$ which was increased $20^{\circ}C/minute$ after two minutes and maintained at the final $140^{\circ}C$ for two minutes. The analysis method was as following: Firstly, ethanol-acetonitrile-acetic acid mixture was classified into four types of concentration (250-25-250 ppm, 1,000-100-1,000 ppm, 3,000-300-3,000 ppm, and 6,000-600-6,000 ppm), and $1.0{\mu}L$ of each type of concentration was injected into gas chromatography followed by an analysis of its peak domain. Then, a calibration-curve by the external standard method was drawn based on the analysis result. Results: While ethanol and acetonitrile were detected in TRACERlab MX, FASTlab had additional acetic acid. The residual quantity of the ethanol-acetonitrile-acetic acid mixture evaluated using the calibration-curve was average 72 ppm ethanol, 54 ppm acetonitrile, and 1030 ppm acetic acid for FASTlab, whereas average 439 ppm ethanol and 79 ppm acetonitrile for TRACERlab MX. This indicated that both of them were within the maximum permissible dose. Conclusion: Solvent residues in the [F-18]FDG injection were all within maximum permissible doses and proper to be used to examine a patient. The result indicated that types and quantities of solvent resides of radioactive pharmaceuticals vary depending on the automatic synthesizer.

  • PDF

Effectors of emtional intelligence, humor sense, and ego resilience on adjustment to the college life of nursing students (간호대학생의 감성지능, 유머감각, 자아탄력성이 대학생활적응에 미치는 영향)

  • Park, Sung Hee;Byun, Eun Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.256-264
    • /
    • 2017
  • This study was conducted to investigate the factors influencing adjustment to college life by nursing college students. Data were collected from 408 nursing students in B city from May 8, 2017 to May 12 and analyzed by ANOVA, Pearson's correlation coefficient, and multiple regression using SPSS/WIN 21.0. The degree of adjustment to college life by nursing students was $3.24{\pm}.49$. There were significant differences in adjustment to college life with respect to grade(t=2.687, p<0.001), age(F=3.187, p=0.042), academic grade(F=18.551, p<0.001), satisfaction with major(F=61.347, p<0.001), and relationship with colleagues (F=28.273, p<0.001). There were positive correlations between adjustment to college life and emotional intelligence(r=0.421, p<0.001), humor sense(r=0.360, p<0.001), and ego resilience(r=0.418, p<0.001). Regression analysis showed 41.7% of variance in nursing student's adjustment to college life was caused by grade, academic scores, satisfaction with major, relationship with colleagues, emotional intelligence, and ego resilience. These results indicated that it is necessary to determine the various factors affecting adjustment to college life and increase adjustment to college life among nursing students.

Development of a Polyvoltine Breed - $BL_{67}$ (Pg) of the Silkworm, Bombyx mori L. with Parthenogenetic Origin

  • Singh, Ravindra;Rao, D.Raghavendra;Gangopadhyay, Debnirmalya;Choudhary, Nazia;Kariappa, B.K.;Dandin, S.B.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.9 no.1
    • /
    • pp.41-46
    • /
    • 2004
  • A breeding programme was initiated by utilizing a robust bivoltine breed CSR$_{18}$ and a polyvoltine breed Cambodge with the main objective of developing robust polyvoltine silkworm breeds/hybrids. At F$_1$ and F$_2$, parthenogenetic development was induced following warm water treatment of eggs at 46$^{\circ}C$ for 18 min followed by two backcrosses with Bl$_{67}$, an evolved polyvoltine breed. The newly developed breed was subjected for hybrid study using eight hybrid combinations in the laboratory at F$_{8}$ generation. F$_1$ hybrids between newly developed breed Bl$_{67}$ (Pg) and promising bivoltine breeds exhibited their superiority by expressing significant hybrid vigour for several economic characters like cocoon yield/10,000 larvae, cocoon weight, cocoon shell weight, cocoon shell ratio and denier. Study on cocoon shape variability revealed that cocoons of all the F$_1$ hybrids except BL$_{67}$ (Pg)${\times}$NB$_4$D$_2$ were found comparatively uniform in shape.pe.

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF