• Title/Summary/Keyword: $[^{18}F]F_2$

Search Result 3,009, Processing Time 0.032 seconds

Clinical Significance of Incidental Asymmetric Palatine Tonsillar Uptake on $^{18}F$-FDG PET/CT ($^{18}F$-FDG PET/CT에서 우연히 관찰되는 구개편도의 비대칭적 섭취증가의 임상적 의의)

  • Chae, Sun-Young;Baek, So-Ra;Ryu, Jin-Sook;Moon, Dae-Hyuk;Kim, Jae-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.402-410
    • /
    • 2009
  • Purpose: The aim of this study was to determine the incidence and malignant rate of incidental asymmetric palatine tonsillar uptake (ATU) on $^{18}F$-FDG PET/CT in various clinical indications and to evaluate the clinical and PET/CT findings suggesting malignancy. Materials and Methods: We retrospectively reviewed a total of 2,901 patients ($58.4{\pm}12.3$ yrs, range 20~88 yrs, M:F = 1,841:1,060) who underwent $^{18}F$-FDG PET/CT during an 1-year period with various indications except primary tonsillar cancer and lymphoma evaluation. On $^{18}F$-FDG PET/CT, metabolic abnormality of the palatine tonsil and cervical lymph node were visually assessed. ATU was defined as increased palatine tonsillar uptake with diffuse, focal, or irregular pattern compared to contralateral side. The incidence and malignant ratio of ATU were evaluated according to clinical and PET/CT findings. Results: Of 2,901 cases, 290(10,0%) showed ATU. The incidence of ATU showed seasonal variation and was high in the winter (12.1%). Of 209 cases with ATU confirmed pathologically and/or clinically, five (2.4%) were malignant lesions. ATU with irregular uptake pattern (2/2) and in cases referred for cervical lymph node metastasis of unknown origin (3/5) were frequently associated with malignant lesion (p<0.05). Conclusion: ATU was not infrequently observed on $^{18}F$-FDG PET/CT, and the malignant risk of ATU was low. However, ATU with cervical lymph node metastasis or with irregular pattern on PET/CT would be further evaluated by the histopathologic examination.

[18F]FET PET is a useful tool for treatment evaluation and prognosis prediction of anti-angiogenic drug in an orthotopic glioblastoma mouse model

  • Kim, Ok-Sun;Park, Jang Woo;Lee, Eun Sang;Yoo, Ran Ji;Kim, Won-Il;Lee, Kyo Chul;Shim, Jae Hoon;Chung, Hye Kyung
    • Laboraroty Animal Research
    • /
    • v.34 no.4
    • /
    • pp.248-256
    • /
    • 2018
  • O-2-$^{18}F$-fluoroethyl-l-tyrosine ($[^{18}F]FET$) has been widely used for glioblastomas (GBM) in clinical practice, although evaluation of its applicability in non-clinical research is still lacking. The objective of this study was to examine the value of $[^{18}F]FET$ for treatment evaluation and prognosis prediction of anti-angiogenic drug in an orthotopic mouse model of GBM. Human U87MG cells were implanted into nude mice and then bevacizumab, a representative anti-angiogenic drug, was administered. We monitored the effect of anti-angiogenic agents using multiple imaging modalities, including bioluminescence imaging (BLI), magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET/CT). Among these imaging methods analyzed, only $[^{18}F]FET$ uptake showed a statistically significant decrease in the treatment group compared to the control group (P=0.02 and P=0.03 at 5 and 20 mg/kg, respectively). This indicates that $[^{18}F]FET$ PET is a sensitive method to monitor the response of GBM bearing mice to anti-angiogenic drug. Moreover, $[^{18}F]FET$ uptake was confirmed to be a significant parameter for predicting the prognosis of anti-angiogenic drug (P=0.041 and P=0.007, on Days 7 and 12, respectively, on Pearson's correlation; P=0.048 and P=0.030, on Days 7 and 12, respectively, on Cox regression analysis). However, results of BLI or MRI were not significantly associated with survival time. In conclusion, this study suggests that $[^{18}F]FET$ PET imaging is a pertinent imaging modality for sensitive monitoring and accurate prediction of treatment response to anti-angiogenic agents in an orthotopic model of GBM.

Development and Validation of 18F-FDG PET/CT-Based Multivariable Clinical Prediction Models for the Identification of Malignancy-Associated Hemophagocytic Lymphohistiocytosis

  • Xu Yang;Xia Lu;Jun Liu;Ying Kan;Wei Wang;Shuxin Zhang;Lei Liu;Jixia Li;Jigang Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.466-478
    • /
    • 2022
  • Objective: 18F-fluorodeoxyglucose (FDG) PET/CT is often used for detecting malignancy in patients with newly diagnosed hemophagocytic lymphohistiocytosis (HLH), with acceptable sensitivity but relatively low specificity. The aim of this study was to improve the diagnostic ability of 18F-FDG PET/CT in identifying malignancy in patients with HLH by combining 18F-FDG PET/CT and clinical parameters. Materials and Methods: Ninety-seven patients (age ≥ 14 years) with secondary HLH were retrospectively reviewed and divided into the derivation (n = 71) and validation (n = 26) cohorts according to admission time. In the derivation cohort, 22 patients had malignancy-associated HLH (M-HLH) and 49 patients had non-malignancy-associated HLH (NM-HLH). Data on pretreatment 18F-FDG PET/CT and laboratory results were collected. The variables were analyzed using the Mann-Whitney U test or Pearson's chi-square test, and a nomogram for predicting M-HLH was constructed using multivariable binary logistic regression. The predictors were also ranked using decision-tree analysis. The nomogram and decision tree were validated in the validation cohort (10 patients with M-HLH and 16 patients with NM-HLH). Results: The ratio of the maximal standardized uptake value (SUVmax) of the lymph nodes to that of the mediastinum, the ratio of the SUVmax of bone lesions or bone marrow to that of the mediastinum, and age were selected for constructing the model. The nomogram showed good performance in predicting M-HLH in the validation cohort, with an area under the receiver operating characteristic curve of 0.875 (95% confidence interval, 0.686-0.971). At an appropriate cutoff value, the sensitivity and specificity for identifying M-HLH were 90% (9/10) and 68.8% (11/16), respectively. The decision tree integrating the same variables showed 70% (7/10) sensitivity and 93.8% (15/16) specificity for identifying M-HLH. In comparison, visual analysis of 18F-FDG PET/CT images demonstrated 100% (10/10) sensitivity and 12.5% (2/16) specificity. Conclusion: 18F-FDG PET/CT may be a practical technique for identifying M-HLH. The model constructed using 18F-FDG PET/CT features and age was able to detect malignancy with better accuracy than visual analysis of 18F-FDG PET/CT images.

Trans-Aortic Flow Turbulence and Aortic Valve Inflammation: A Pilot Study Using Blood Speckle Imaging and 18F-Sodium Fluoride Positron Emission Tomography/Computed Tomography in Patients With Moderate Aortic Stenosis

  • Soyoon Park;Woo-Baek Chung;Joo Hyun O;Kwan Yong Lee;Mi-Hyang Jung;Hae-Ok Jung;Kiyuk Chang;Ho-Joong Youn
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.3
    • /
    • pp.145-149
    • /
    • 2023
  • BACKGROUND: 18F-sodium fluoride positron emission tomography/computed tomography (18F-NaF PET/CT) has been proven to be useful in identification of microcalcifications, which are stimulated by inflammation. Blood speckle imaging (BSI) is a new imaging technology used for tracking the flow of blood cells using transesophageal echocardiography (TEE). We evaluated the relationship between turbulent flow identified by BSI and inflammatory activity of the aortic valve (AV) as indicated by the 18F-NaF uptake index in moderate aortic stenosis (AS) patients. METHODS: This study enrolled 18 moderate AS patients diagnosed within the past 6 months. BSI within the aortic root was acquired using long-axis view TEE. The duration of laminar flow and the turbulent flow area ratio were calculated by BSI to demonstrate the degree of turbulence. The maximum and mean standardized uptake values (SUVmax, SUVmean) and the total microcalcification burden (TMB) as measured by 18F-NaF PET/CT were used to demonstrate the degree of inflammatory activity in the AV region. RESULTS: The mean SUVmean, SUVmax, and TMB were 1.90 ± 0.79, 2.60 ± 0.98, and 4.20 ± 2.18 mL, respectively. The mean laminar flow period and the turbulent area ratio were 116.1 ± 61.5 msec and 0.48 ± 0.32. The correlation between SUVmax and turbulent flow area ratio showed the most positive and statistically significant correlation, with a Pearson's correlation coefficient (R2) of 0.658 and a p-value of 0.014. CONCLUSIONS: The high degree of trans-aortic turbulence measured by BSI was correlated with severe AV inflammation.

Ecological Characteristics of Bombus ignitus Smith in Korea (한국산 호박벌(Bombus ignitus Smith)의 생태적 특성)

  • ;;;;M. Bilinski
    • Korean journal of applied entomology
    • /
    • v.38 no.2
    • /
    • pp.101-107
    • /
    • 1999
  • Queens of Korean native bumblebee species, Bombus ignitus were collected from the field in the spring of 1998 to investigate their ecological characteristics and reared under the laboratory conditions; 3 0 f 1$^{\circ}$C, 55 25% of relative humidity and darkness. As a result, 94.4% of the queens laid eggs in 6.00f 2.41 days after the field collection. The first worker and the first drone from the egg cell of the collected queens appeared in 18.90 f 1.16 and 68.96 f 3.94 days, respectively. In the colony foundation, 86.1% of the collected queens founded their colony, and 96.8% of them produced new queens in 71.14f 6.88 days. The life span of the colony-founded queen covered for 86.90f24.35 days, whereas that of non-colonized queen for 15.67 f 7.37 days. One colony sized as big as 987.82f 145.84 in number, composing of workers (188.79f 18.23), drones (691.10f 159.24) and queens (107.93 f47.48). Copulation lasting time of queen and drone took 23.00f 7.33 minutes in average. In a new queen emergence, there were two patterns; single peak type of new queen emergence in 12.31 k6.95 days and two peaks type of it in 74.00f 17.61 days. The number of eggs per egg cell of new queen averaged as 8.86f 4.00 grains and an egg period covered 3 days after oviposition. An egg cell sized as 7.15 f0.88 mm in a width, 7.79 f 1 .l 1 mm in a length and 3.33 f 0.23 mm in a height. An egg shaped as banana and sized as 1.22 f 0.09 mm in a width and as 3.5 1 f 0.21 mm in a length, weighing as 2.70 + 0.30 mg.

  • PDF

Performance of Three-Layered Organic Light-Emitting Diodes Using the Hole-Transport and Injection Layer of TPD and Teflon-AF, and the Electron-Injection Layer of Li2CO3 and LiF

  • Shin, Jong Yeol;Kim, Tae Wan;Kim, Gwi Yeol;Lee, Su Min;Hong, Jin Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.89-92
    • /
    • 2017
  • The performance of three-layered organic light-emitting diodes (OLEDs) was investigated using TPD hole-transport and injection layers, Teflon-AF, and the electron-injection layer of $Li_2CO_3$ and LiF. The OLEDs were manufactured in a structure of TPD/$Alq_3$/LiF, TPD/$Alq_3$/$Li_2CO_3$, and AF/$Alq_3$/LiF using low-molecular organic materials. In three different three-layered OLEDs, it was found that the device with the TPD/$Alq_3$/LiF structure shows higher performance in maximum luminance, and maximum external quantum efficiency compared to those of the device with TPD/$Alq_3$/$Li_2CO_3$ and TPD/$Alq_3$/LiF by 35% and 17%, and 193% and 133%, respectively. It is thought that the combined LiF/Al cathode contributes to a reduced work function and improves an electrical conduction mechanism due to the electron injection rather than the hole transport, which then increases a recombination rate of charge carriers.

The Severity of the Pediatric Patients Visiting Emergency Center (응급실 방문 환아의 중증도)

  • Kim Shin-Jeong;Moon Sun-Young;Park Eun-Ok
    • Child Health Nursing Research
    • /
    • v.7 no.2
    • /
    • pp.191-202
    • /
    • 2001
  • This study was attempted to help in explore new direction about classification of the severity of the pediatric patients visiting emergency center. Data were collected from 276 patients who visited emergency center of E University Hospital during 3 months period from March 1, to May 31,1999. The results were as follows: 1. The degree of severity of the pediatric patients visiting emergency center shown ranged 0-18 and averaged .87. 2. With the respect to the severity of the pediatric patients visiting emergency center, there were statiscally significant difference in patients' visiting time(F=2.607, p=.025), disease classification(F=9.606, p=.000), consciousness level(F=71.499, p=.000), period of symptom manifestation (F=2.262, p=.030), pediatric patients protector's thinking about pediatric patients state (F=16.833, p=.000), treatment outcome (t=5.362, p=.000), duration of stay at emergency center(F=23.944, p=.000).

  • PDF

전술 항공정찰체계 발전 방향(2)

  • Go, Jae-Il
    • Defense and Technology
    • /
    • no.11 s.237
    • /
    • pp.58-65
    • /
    • 1998
  • 새로운 전술 정찰장비의 개발은 미 공군 이외에도 미 해군과 해병대에서도 F-14와 F-18 전투기에 장착 가능한 전술 정찰용 장비의 개발이 추진되고 있으며, 영국에서는 Tornado를, 프랑스에서는 Mirage와 Rafale을, 이스라엘, 덴마크, 네덜란드 등은 F-16을 유인 전술 정찰기로 사용하기 위해 새로운 전술정찰 체계를 자체 개발하거나 합작 생산을 추진하고 있다.

  • PDF

Group Delay Time Matched CMOS Microwave Frequency Doubler (군지연 시간 정합 CMOS 마이크로파 주파수 체배기)

  • Song, Kyung-Ju;Kim, Seung-Gyun;Choi, Heung-Jae;Jeong, Yong-Chae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.7
    • /
    • pp.771-777
    • /
    • 2008
  • In this paper, a frequency doubler using modified time-delay technique is proposed. A voltage controlled delay line (VCDL) in the proposed frequency doubler compensates the group delay time mismatching between input and delayed signal. With the group delay time matching and waveform shaping using the adjustable Schmitt triggers, the unwanted fundamental component($f_0$) and the higher order harmonics such as third and fourth are diminished excellently. In result, only the doubled frequency component($2f_0$) appears dominantly at the output port. The frequency doubler is designed at 1.15 GHz of $f_0$ and fabricated with TSMC $0.18\;{\mu}m$ CMOS process. The measured output power at $2f_0$ is 2.67 dBm when the input power is 0 dBm. The obtained suppression ratio of $f_0,\;3f_0$, and $4f_0$ to $2f_0$ are 43.65, 38.65 and 35.59 dB, respectively.

18-FDG EXTERNAL RADIATION DOSE RATES IN DIFFERENT BODY REGIONS OF PET-MRI PATIENTS

  • Han, Eunok;Kim, Ssangtae
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.3
    • /
    • pp.157-165
    • /
    • 2013
  • To determine the factors affecting the external radiation dose rates of patients undergoing PET-MRI examinations and to assess the trends of these differences, we measured the changes in the dose rates of $^{18}F$-FDG during a set period of time for each body region. Consistent with theoretical predictions, the dose rate decreased over time in patients undergoing PET-MRI examinations. Furthermore, immediately after the $^{18}F$-FDG injection, the dose rate in the chest region was the highest, followed by the abdominal region, the head region, and the foot region. The dose rate decreased drastically as time passed, by 2.47-fold, from $339.23{\pm}74.70mSv\;h^{-1}$ ($6.73{\pm}5.79$ min) at the time point immediately after the $^{18}F$-FDG injection to $102.71{\pm}26.17mSv\;h^{-1}$ ($136.11{\pm}25.64$ min) after the examination. In the foot region, there were no significant changes over time, from $32.05{\pm}20.23mSv\;h^{-1}$ ($6.73{\pm}5.79$ min) at the time point immediately after the $^{18}F$-FDG injection, to $23.89{\pm}9.14mSv\;h^{-1}$ ($136.11{\pm}25.64$ min) after the examination. The dose rate is dependent on the individual characteristics of the patient, and differed depending on the body region and time point. However, the dose rates were higher in patients who had a lower body weight, shorter stature, fewer urinations, lower fluid intake, and history of diabetes mellitus. To decrease radiation exposure, it is difficult or impossible to change factors inherent to the patient, such as sex, age, height, body weight, obesity, and history of diabetes mellitus. However, factors which can be changed, such as the $^{18}F$-FDG dose, fasting time, fluid intake, number of urinations, and contrast agent dose can be controlled to minimize the external radiation exposure of the patient.