• 제목/요약/키워드: "On-water"

검색결과 61,475건 처리시간 0.082초

태백권 배수관망 개량사업의 비용효과분석 최적화 모델 연구 (A Study on Cost Benefit Analysis Optimization Model for Water Distribution Network Rehabilitation Project of Taebaek Region)

  • 김태곤;최태호;김경필;구자용
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.395-406
    • /
    • 2015
  • This research carried out an analysis on input cost and leakage reduction effect by leakage reduction method, focusing on the project for establishing an optimal water pipe network management system in the Taebaek region, which has been executed annually since 2009. Based on the result, optimal cost-benefit analysis models for water distribution network rehabilitation project were developed using DEA(data envelopment analysis) and multiple regression analysis, which have been widely utilized for efficiency analysis in public and other projects. DEA and multiple regression analysis were carried out by applying 4 analytical methods involving different ratios and costs. The result showed that the models involving the analytical methods 2 and 4 were of low significance (which therefore were excluded), and only the models involving the analytical methods 1 and 3 were suitable. From the result it was judged that the leakage management method to be executed with the highest priority for the improvement of revenue water ratio was installation of pressure reduction valve, followed by replacement of water distribution pipe, replacement of water supply pipe, and then leakage detection and repair; and that the execution of leakage management methods in this order would be most economical. In addition, replacement of water meter was also shown to be necessary in case there were a large number of defective water meters.

Implementations of Remote Sensing, GIS, and GPS for Water Resources and Water Quality Monitoring

  • Wu, Mu-Lin;Chen, Chiou-Hsiung;Liu, Shiu-Feng;Wey, Jiun-Sheng
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1191-1193
    • /
    • 2003
  • Water quantity and quality monitoring at Taipei Watershed Management Bureau (WRATB) is not only a daily business but also a long term job. WRATB is responsible for providing high quality drinking water to about four millions population in Taipei. The quality of drinking water provided by WRATB is among one of the best in Taiwan. The total area is 717 square kilometers. The water resource pollution is usually divided into two categories, point source pollution and nonpoint source pollution. Garbage disposal is the most important component of the point source pollution, especially those by tourist during holidays and weekends. Pesticide pollution, fertilizer pollution, and natural pollution are the major contributions for nonpoint source pollution. The objective of this paper is to implement remote sensing, geographic information systems, and global positioning systems to monitor water quantity and water quality at WRATB. There are 12 water quality monitoring stations and four water gauge stations at WRATB. The coordinates of the 16 stations were determined by GPS devices and created into the base maps. MapObjects and visual BASIC were implemented to create application modules for water quality and quantity monitoring. Water quality of the two major watersheds at WRATB was put on Internet for public review monthly. The GIS software, ArcIMS, can put location maps and attributes of all 16 stations on Internet for general public review and technical implementations at WRATB. Inquiry and statistic charts automatic manipulations for the past 18 years are also available. Garbage disposal by community and tourist were also managed by GIS and GPS. The storage, collection, and transportation of garbage were reviewed by ArcMap file format. All garbage cart and garbage can at WRATB can be displayed on the base maps. Garbage disposal by tourist during holidays and weekends can be managed by a PDA with a GPS device and a digital camera. Man power allocation for tourist garbage disposal management can be done in an integration of GIS and GPS. Monitoring of water quality and quantity at WRATB can be done on Internet and by a PDA.

  • PDF

AquaCrop을 이용한 기후변화에 따른 미래 논벼 물발자국 변화 분석 (Analysis of Paddy Rice Water Footprint under Climate Change Using AquaCrop)

  • 오부영;이상현;최진용
    • 한국농공학회논문집
    • /
    • 제59권1호
    • /
    • pp.45-55
    • /
    • 2017
  • Climate change causes changes in rainfall patterns, temperature and drought frequency. Climate change impact influences on water management and crop production. It is critical issue in agricultural industry. Rice is a staple cereal crop in South Korea and Korea uses a ponding system for its paddy fields which requires a significant amount of water. In addition, water supply has inter-relationship with crop production which indicates water productivity. Therefore, it is important to assess overall impacts of climate change on water resource and crop production. A water footprint concept is an indicator which shows relationship between water use and crop yield. In addition, it generally composed of three components depending on water resources: green, blue, grey water. This study analyzed the change trend of water footprint of paddy rice under the climate change. The downscaled climate data from HadGEM3-RA based on RCP 8.5 scenario was applied as future periods (2020s, 2050s, 2080s), and historical climate data was set to base line (1990s). Depending on agro-climatic zones, Suwon and Jeonju were selected for study area. A yield of paddy rice was simulated by using FAO-AquaCrop 5.0, which is a water-driven crop model. Model was calibrated by adjusting parameters and was validated by Mann-Whitney U test statistically. The means of water footprint were projected increase by 55 % (2020s), 51 % (2050s) and 48 % (2080s), respectively, from the baseline value of $767m^2/ton$ in Suwon. In case of Jeonju, total water footprint was projected to increase by 46 % (2020s), 45 % (2050s), 12 % (2080s), respectively, from the baseline value of $765m^2/ton$. The results are expected to be useful for paddy water management and operation of water supply system and apply in establishing long-term policies for agricultural water resources.

실용 가능한 최적처리기술에 근거한 산업폐수 배출허용기준 설정 연구 - 펄프.종이 및 종이제품 제조시설 적용 사례 (Study on Establishment of the Industrial Wastewater Effluent Limitations Based on Best Practicable Control Technology Currently Available - Case Study for the Pulp, Paper and Paper Board Manufacturing)

  • 김재훈;신진수;이철구;이정영;이영선;유순주
    • 한국물환경학회지
    • /
    • 제28권4호
    • /
    • pp.608-614
    • /
    • 2012
  • The effluent limitation of industrial wastewater is based on uniform regulatory criteria for effluent discharge facilities of all in Korea. But, an individual effluent limitation on each effluent discharge facility is widely applicable for regulation of industrial wastewater in US.EPA. To decide an individual effluent limitation, TBEL (Technology-based effluent limitation) and WQBEL (Water quality-based effluent limitation) are used. TBEL is based on the capability of a treatment technology to reduce the pollutants. WQBEL is based on ambient water quality standards. In this study, TBEL were derived for the pulp, paper and paper board manufacturing based on best practicable control technology currently available. It was suggested that effluent limitations were $BOD_5$ 4.7 mg/L, $COD_{Mn}$ 44.3 mg/L, SS 13.2 mg/L, TN 1.4 mg/L, TP 0.15 mg/L and best practicable control technology currently available (BPT) was neutralization, activated sludge treatment and coagulation and sedimentation for the pulp, paper and paper board manufacturing.

지불의사를 이용한 상수도 원수수질개선 편익 산정 (Estimation of Raw Water Quality Improvement Benefit of Water Service Using WTP)

  • 여규동;이충성;이상원;심명필
    • 대한토목학회논문집
    • /
    • 제29권5B호
    • /
    • pp.419-427
    • /
    • 2009
  • 기존의 WTP를 이용한 수질개선 관련 편익산정 연구들은 특정 하천에 대하여 '모든 종류의 물놀이 가능한 2급수로 개선', '수영가능수준으로 개선' 등을 설문대상으로 하여 지불의사를 산정한 다음, 해당 유역의 가구수를 곱하여 편익으로 산정하였다. 이는 특정 수자원개발사업에 대한 편익이 아니며, 설문작성 과정에서 수질개선 정도에 대한 객관적인 설명이 부족하고, 단순화되었기 때문에 설문응답자들에게 설문대상재화에 대한 정보를 전달하는데 미흡한 점이 있었다. 따라서 본 연구에서는 수자원개발사업시 상수도 원수수질개선에 대한 편익/비용분석에 적용할 수 있는 편익산정방법론을 제시하였다. 본 연구에서는 수도권을 대상으로 하여 용수를 사용하는 소비자의 BOD 개선정도별 지불의사(WTP)를 설문을 조사하고, 설문결과를 통계분석하여 수질개선-지불의사 관계식을 도출하였다. 사례연구로서 낙동강수계의 내성천 지방2급하천 구간에 계획한 송리원 다목적댐을 대상으로 적용하였다. 방류시나리오별 연평균편익산정 결과, 연평균계획방류량($4.79m^3/s$) 방류시 5,980 백만원, 풍수기(7~10월)를 제외한 기간의 계획방류량($7.22m^3/s$) 방류시 8,663 백만원, 수질악화기 계획방류량($10.72m^3/s$) 방류시 11,905 백만원, 최대계획방류량($13.54m^3/s$) 방류시 14,502 백만원으로 산정되었다. 본 연구에서 개발된 가구소득별 수질개선 (BOD)-지불의사(WTP) 관계식을 이용함으로써 수질개선사업에 대한 원수수질편익을 산정할 때 수질개선정도에 상관없이 쉽게 편익을 산정할 수 있을 것으로 판단된다.

농업용수의 수온 상승에 관한 연구

  • 황은;김철규;이상범
    • 물과 미래
    • /
    • 제5권2호
    • /
    • pp.17-29
    • /
    • 1972
  • The persent study aims at finding out a means of prevention cool spell damages on the hilly areas. The irrigation plots of 24 hour stored water warm water way and warm water plots, cool water way are respectively established to find out water temperature and influnce on the growing rice plants. The results obtained are summed up as follows. 1. Warm water areas consisted of $5 m^2 Q=0.93 1{\ell}/sec$, V=31 cm/sec, S=1/1, 000, L=81.6m, B=5cm, h=6cm, t=4min 33sec, drops=9 areas, are constructed to help the water temperature of $14.5^{\circ}C$ rise to that of $21.6^{\circ}C$. This indicates lower temperature than $23^{\circ}C$ of critical water temperature in irrigation facilities by $1.45^{\circ}C$ and than $26.2^{\circ}C$ of balanced water temperature of Seoul arears by $4.6^{\circ}C$. But this does not give much influance on rice plant cultivation. 2. The rising of water temperature is influened according to the temperature, solar radiation but the water temperature changes according to the heat absorption of organized materials, weather and terraces. The difference of water temperature could be found in the first growing stage. 3. Through the warm water way of water rises to the temperature of $21.6^{\circ}C$ which also rises to the temperature of around $30^{\circ}C$ in the paddy field of submerged irrigation. The rice plants are comparatively free from prolonged cool damage, reproduction abstructive damage. 4. The water temperature in rice field in proportion to temperature influence of weather condition but the water temperature approaches to that of weather in the days of later growing stage and water temperature become lower than the air temperature in the fruit stage. 5. The water in the submreged field is $10^{\circ}C$ warmer than in the warm water way during the first growing stage period but the water temperature in the warm water way is warmer in the later growing stage period. The cool water of $14.5^{\circ}C$ is warmed to $30.1^{\circ}C$ and rice plants cultivation is free from other damages. 6. The 12% increased production or 570.98kg/10a is made cool water plot by rising the temperature of water from $14.5^{\circ}C$ to $21.6^{\circ}C$ making the water run through warm water way. 7. The damage inflicted by the cool water irrigation during the first growing stage period is the obstruction of peak tillering stage and the obstruction of heading the later growing stage period and the obstruction of fruiting and number of panides per fill.

  • PDF

흙-수분 특성곡선 방정식을 이용한 체적함수비의 예측 (Prediction of the Volumetric Water Content Using the Soil-Water Characteristic Curve on an Unsaturated Soil)

  • 송창섭
    • 한국환경복원기술학회지
    • /
    • 제7권6호
    • /
    • pp.39-48
    • /
    • 2004
  • The purpose of this paper was to confirm the application of the equation of the soil-water characteristic curve on an unsaturated soil. To this ends, a series of suction test was conducted on the selected 4 kinds of soil which is located in Korea, using the modified pressure extractor apparatus. And it was carried out to analyze the experimental parameters which can describe the soil-water characteristics, were determined by using the data obtained from the experiment. From the results, it was found that the matric suction was varied according to the grain size distribution, amount of fine grain particle and void ratio. Also it was found that the residual volumetric water content was decreased with the void ratio, but the index related air entry value, the soil parameter related water content and the parameter with residual water content were increased with the void ratio. And the application of equation of the soil-water characteristic curve was confirmed for the various conditions and the various state by the comparison between the volumetric water content measured by the experiment and the predicted values.

증발수 유량이 간접 증발식 냉각기 성능에 미치는 영향 (Effects of Evaporation Water Flow Rate on the Performance of an Indirect Evaporative Cooler)

  • 추현선;이관수;이대영
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.714-721
    • /
    • 2006
  • In evaporative cooling applications, the evaporation water is supplied usually sufficiently larger than the amount evaporated to enlarge contact surface between the water and the air. Especially in indirect evaporative coolers, however, if the evaporation water flow rate is excessively large, the evaporative cooling effect is not used for heat absorption from the hot fluid but spent to the sensible cooling of the evaporation water itself. This would result in a decrease in the cooling performance of the indirect evaporative cooler. In this study, the effects of the evaporation water flow rate on the cooling performance are investigated theoretically. The cooling process in an indirect evaporative cooler is modeled into a set of linear differential equations and solved to obtain the exact solutions to the temperatures of the hot fluid, the moist air, and the evaporation water. Based on the exact solutions, it is analyzed how much the cooling performance is affected by the evaporation water flow rate. The results show that the decrease in the cooling effectiveness is substantial even for a small flow rate of the evaporation water and the relative decrease is more serious for a high-performance evaporative cooler.

Pulsed Electric Field Effects to Reduce the Level of Campylobacter spp. in Scalder and Chiller Water during Broiler Chicken Processing

  • Shin, Dae-Keun;Martin, Bradely C.;Sanchez-Plata, Marcos X.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제24권9호
    • /
    • pp.1314-1317
    • /
    • 2011
  • To evaluate the effects of pulsed electric field (PEF) application on scalder and chiller water on Campylobacter contamination, four different treatments under three different water conditions including hard scalder water ($55^{\circ}C$), soft scalder water ($45^{\circ}C$) and chiller water, were applied as follows: i) a control treatment with no salt and no electric treatment, ii) a PEF only treatment, iii) a PEF treatment with 0.5% salt water, and iv) a PEF treatment with 1% salt water treatment. The use of PEF in hard scalding water showed an effect of reducing Campylobacter when compared to the control during the 200 s timeframe. With the addition of salt, the intervention caused at least 5.81 log CFU/ml reduction of Campylobacter counts after 200 s of PEF exposure. Similar effects were observed under soft scalding conditions. Campylobacter reductions were evident under chilling conditions with up to 2.00 log for PEF only, 5.77 log for PEF+0.5% salt and 2.69 log for PEF+1% salt treatment in water. Therefore, the current PEF setting for the scalder and chiller water can be successfully used to reduce pathogenic loads of Campylobacter on broiler chicken carcasses, and further research may be necessary to apply it in the poultry processing industry.

태양열 온수기를 이용한 다목적 공조시스템의 재생효율에 관한 연구(제1보 액체흡수제 온도가 재생량에 미치는 영향) (Research on the Performance of Regenerator using Hot Water from Solar Water Heater(1st paper : On the Effect of Solution Temperature to Regeneration Rate))

  • 우종수;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제24권1호
    • /
    • pp.53-61
    • /
    • 2004
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an efficient solar water heater, this study examines a regeneration process using hot water obtained from solar water heater to recover absorption potential by evaporating moisture in the liquid desiccant. In this paper, a solar absorption dehumidifying system with solar water heater is suggested to save the electricity for operating an air conditioner. LiGl(lithium chloride) solution was adopted as a liquid desiccant in the proposed system, and hot water obtained from the solar water heater was used for regenerating the liquid desiccant. As a result, it was clear that the dilute LiCl solution could be regenerated by hot water, and the regeneration rate depends mostly on temperature level of liquid desiccant. The regeneration rates were about 2.4kg/h with $40^{\circ}C$, 4.0kg/h with $50^{\circ}C$, and 6.2kg/h with $60^{\circ}C$ of hot water respectively.