• 제목/요약/키워드: "On-water"

검색결과 61,231건 처리시간 0.066초

정수장 운영에 영향을 미치는 기후변화 요인 분석 (Effect of Climate Change Characteristics on Operation of Water Purification Plant)

  • 장유정;최현우;이서준;최재영;최현수;오희경
    • 한국물환경학회지
    • /
    • 제40권2호
    • /
    • pp.89-100
    • /
    • 2024
  • Climate change has a broad impact on the entire water environment, and this impact is growing. Climate adaptation in water supply systems often involves quantity and quality control, but there has been a lack of research examining the impacts of climatic factors on water supply productivity and operation conditions. Therefore, the present study focused on, first, building a database of climatic factors and water purification operating conditions, and then identifying the correlations between factors to reveal their impacts. News big data was analyzed with keywords of climatic factors and water supply systems in either nationwide or region-wide analyses. Metropolitan area exhibited more issues with cold waves whereas there were more issues with drought in the Southern Chungcheong area. A survey was conducted to seek experts' opinions on the climatic impacts leading to these effects. Pre-chlorination due to drought, high-turbidity of intake water due to rainfall, an increase of toxins in intake water due to heat waves, and low water temperature due to cold waves were expected. Pearson correlation analysis was conducted based on meteorological data and the operating data of a water purification plant. Heavy rain resulted in 13 days of high turbidity, and the subsequent low turbidity conditions required 3 days of high coagulant dosage. This insight is expected to help inform the design of operation manuals for waterworks in response to climate change.

방사보가 도시하천수질에 미치는 영향에 관한 연구 (A study of the Effect of groin on the Water Quality in the Urban River)

  • 조홍제;김일권
    • 상하수도학회지
    • /
    • 제12권3호
    • /
    • pp.81-90
    • /
    • 1998
  • The purpose of this study was to analyze the effect of the groin which was constructed in the down stream of urban river for the prevention of sedimentation on the improvement of the water quality. We studied on the groin in the downstream of Taehwa River constructed to keep the navigation depth of Ulsan day, and used the measured data of the water quality and river discharge. In order to analyze the charge of the water quality due to the groin Que12E model was applied, and BOD and DO was examined. The analysis showed that removal of the groin would not have significant effect on the improvement of the water quality, rather, interception of the pollution source coming into the upstream of the groin would be more influential on the improvement of the water quality. Therefore, It was concluded that to improve the water quality in mild bottom slop of tidal river, interception of the pollution source and river maintenance discharge should precede.

  • PDF

C계수의 추정오차가 배수관망해석에 미치는 영향 (Effect of C Factor Errors on the Analysis of Water Distribution Systems)

  • 현인환;이철규
    • 상하수도학회지
    • /
    • 제13권2호
    • /
    • pp.23-33
    • /
    • 1999
  • This study is to investigate the effect of C factor errors on the analysis of water distribution systems. For this purpose, an artificial distribution network and a real distribution network were selected as the study networks. Results are as follows. 1. The C factor of a pipe which has small velocity didn't give significant effect on the analysis of a water distribution system. 2. The effect of decreased value of C factors give more influence on the analysis of water distribution systems than that of the increased values. 3. For the C factor calibration, errors of the residual water heads as well as those of the head losses should be considered together. 4. In the analysis of water distribution systems, changes of C factors can give influences only on the nodes which locate behind the pipe. Therefore, this characteristics should be considered in the selection of nodes for the measurement of water heads.

  • PDF

미분무수 첨가제의 소화효과 비교 (Comparison of Fire Extinguishing Effects for Water Mist Additives)

  • 김승일;신창섭
    • 한국안전학회지
    • /
    • 제28권6호
    • /
    • pp.23-28
    • /
    • 2013
  • In order to improve extinguishing performance of water mist, many studies of additives have been conducted. In this study, viscosity agent which has the ability to improve extinguishing performance by adhering to the surface on fire was used and fluorine-free surfactant was also added to water to enhance water's wetting ability. This study aimed to verify optimal concentration of extinguishing of additives according to fire source and extinguishing performance by comparison with pure water. In case of wood crib fire, the results show that flame suppression and extinguishing time of sodium alginate 0.4 wt.% are 3.4 times and 2.2 times shorter than those of pure water in 0.2 MPa respectively. It seems that large amount of water adhere to surface on fire, thus cooling effect on surface was enhanced. Also water consumption of sodium alginate 0.4wt.% is up to 65% lower than that of pure water. In case of heptane fire, extinguishing time of cocobetaine 0.1 wt.% is 9.7 times shorter than that of pure water in 0.2 MPa. It is thought that because cocobetaine can block oxygen and suppress oil mist by making emulsion film on fire surface due to a low surface tension. On the other hand, water consumption of cocobetaine 0.1 wt.% is 92% lower than that of pure water.

고해상도 기후시나리오를 이용한 논용수 수요량 및 단위용수량의 기후변화 영향 분석 (The Impacts of Climate Change on Paddy Water Demand and Unit Duty of Water using High-Resolution Climate Scenarios)

  • 유승환;최진용;이상현;오윤경;박나영
    • 한국농공학회논문집
    • /
    • 제54권2호
    • /
    • pp.15-26
    • /
    • 2012
  • For stable and sustainable crop production, understanding the effects of climate changes on agricultural water resources is necessary to minimize the negative effects which might occur due to shifting weather conditions. Although various studies have been carried out in Korea concerning changes in evapotranspiration and irrigation water requirement, the findings are still difficult to utilize fordesigning the demand and unit duty of water, which are the design criteria of irrigation systems. In this study, the impact analysis of climate changes on the paddy water demand and unit duty of water was analyzed based on the high resolution climate change scenarios (specifically under the A1B scenario) provided by the Korea Meteorological Administration. The result of the study indicated that average changes in the paddy water demand in eight irrigation districts were estimated as -2.4 % (2025s), -0.2 % (2055s), and 3.2 % (2085s). The unit duty of water was estimated to increase on an average within 2 % during paddy transplanting season and within 5 % during growing season after transplanting. This result could be utilized for irrigation system design, agricultural water resource development, and rice paddy cultivation policy-making in South Korea.

미나리 생즙 투여가 개의 혈액상에 미치는 영향 (Hematological Changes in Dogs Administrated Excessive Amount of Water Celery Crude Juice)

  • 김홍태;장혜숙;안병만;김영홍;장광호
    • 한국임상수의학회지
    • /
    • 제18권2호
    • /
    • pp.105-110
    • /
    • 2001
  • The water celery, Oenanthe Javanica DC., is a perennial herb which mostly grows on a damp ground or a streamside. The water celery is widely distributed in Korea, Japan, china, Taiwan, Indonesia, Malaysia and the other countries. From ancient times, the water celery has widely been used for food or medicine. In herbal medicine, the water celery has a medical actions which are defervescence, diuresis, jaundice, edema, hypotensor, haematic, angiostasis, sthenia, appetizer. Recently, studies on the water celery are briskly being conducted. For example, studies on the morphologic property and classifications of origin of the water celery, studies on the chemical constituents of the water celery which contains vitamins, proteins and amino acids, studies on the bio activities of the water celery which contains flavonoids. However, there is not studies of hematological changes in dogs administrated the water celery until now. Consicontly, this study was conducted to observed the hematological changes in dogs administrated excessive amount of the water celery crude juice for a long period. In this studies, all dogs showed significantly decrease of the PCV and Hb, and increase of the WBC, GSH and reticulocytes, but did not significantly change in the RBC, MCV, MCHC and Met-Hb.

  • PDF

화성호 유역의 수질관리를 위한 유역모델링 연구 (Watershed Modeling Research for Receiving Water Quality Management in Hwaseong Reservoir Watershed)

  • 장재호;강형식;정광욱
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.819-832
    • /
    • 2012
  • HSPF model based on BASINS was applied for the Hwaseong Reservoir watershed (HRW) to evaluate the feasibility of water quality management. The watershed was divided into 45 sub-basins considering various watershed environment. Streamflow was calibrated based on the measured meteorological data, discharge data of treatment plants and observed streamflow data for 2010 year. Then the model was calibrated against the field measurements of water qualities, including BOD, T-N and T-P. In most cases, there were reasonable agreements between observed and predicted data. The validated model was used to analyze the characterization of pollutant load from study area. As a result, Non-point source pollutant loads during the rainy season was about 66~78% of total loads. In rainy-season, water quality parameters depended on precipitation and pollutant loads patterns, but their concentration were not necessarily high during the rainy season, and showed a decreasing trend with increasing water flow. As another result of evaluation for load duration curves, in order to improve water qualities to the satisfactory level, the watershed managements considering both time-variant and pollution sources must be required in the HRW. Overall, it was found that the model could be used conveniently to assess watershed characteristics and pollutant loads in watershed scale.

SWAT모델과 물수지분석을 이용한 물재이용에 의한 도시물순환 변화 분석 (Analysis for water cycle change using SWAT model and water balance analysis depending on water reuse in urban area)

  • 김영란;황성환;이성옥
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.447-457
    • /
    • 2015
  • Water cycle within the human civilization has become important with urbanization. To date, water cycle in the eco-system has been the focus in identifying the degree of water cycle in cities, but in practicality, water cycle within the human civilization system is taking on an increasing importance. While in recent years plans to reuse water have been implemented to restore water cycle in cities, the effect that such reuse has on the entire water cycle system has not been analyzed. The analysis on the effect that water reuse has on urban areas needs to be go beyond measuring the cost-savings and look at the changes brought about in the entire city's water cycle system. This study uses a SWAT model and water balance analysis to review the effects that water reuse has on changes occurring in the urban water cycle system by linking the water cycle within the eco-system with that within the human civilization system. The SWAT model to calculate the components of water cycle in the human civilization system showed that similar to measured data, the daily changes and accumulative data can be simulated. When the amount of water reuse increases in urban areas, the surface outflow, amount of sewer discharge and the discharged amount from sewage treatment plants decrease, leading to a change in water cycle within our human civilization system. The determinant coefficients for reduced surface outflow amount and reduced sewer discharge were 0.9164 and 0.9892, respectively, while the determinant coefficient for reduced discharge of sewage treatment plants was 0.9988. This indicates that with an increase in water reuse, surface flow, sewage and discharge from sewage treatment plants all saw a linear reduction.

정수처리장 내의 미세플라스틱의 유입 및 처리기술 현황에 관한 고찰 (A mini-review on microplastics in drinking water treatment processes)

  • 최병규;김지윤;최수훈
    • 상하수도학회지
    • /
    • 제34권5호
    • /
    • pp.357-371
    • /
    • 2020
  • Microplastics have become a rising issue in due to its detection in oceans, rivers, and tap water. Although a large number of studies have been conducted on the detection and quantification in various water bodies, the number of research conducted on the removal and treatment of microplastics are still comparatively low. In the current research, the inflow and removal of microplastics were investigated for various drinking water treatment plants around the world. Addition to the investigation of filed research, a survey was also conducted on the current research trend on microplastic removal for different treatment processes in the drinking water treatment plants. This includes the researches conducted on coagulation/flocculation, sedimentation, dissolved air flotation, sand filtration and disinfection processes. The survey indicated mechanisms of microplastic removal in each process followed by the removal characteristics under various conditions. Limitations of current researches were also mentioned, regarding the gap between the laboratory experimental conditions and field conditions of drinking water treatment plants. We hope that the current review will aid in the understanding of current research needs in the field of microplastic removal in drinking water treatment.

회수수가 응집공정의 오염물질 제거 및 입자특성에 미치는 영향 (Effects of Recycled Washwater on Pollutant Removal and Particle Characteristics during Coagulation)

  • 문병현;김승현;박미선;이향인;이강춘
    • 한국환경과학회지
    • /
    • 제11권9호
    • /
    • pp.955-960
    • /
    • 2002
  • The recycled washwater, which has different water quality and is produced about 5 to 20% of the total water volume treated, affects the unit operation of water treatment, especially coagulation process. However, the effects of recycled washwater on unit operation of water treatment have not been fully investigated. In this study, effects of recycled washwater on coagulation process were investigated to find the optimum coagulation condition by analyzing turbidity, $UV_{254}$, TOC removal efficiencies. In addition, effects of recycled washwater on residual Al after coagulation were studied by analyzing soluble and particulate Al. The size distribution and fractal dimension of coagulated also analyzed. The recycled washwater was lower pH than the raw water. And the recycled washwater had higher $UV_{254}$, TOC and residual Al concentration than the raw water. Residual Al concentration of recycled washwater was about 50 times higher than that of raw water. Optimum coagulant dosages on the blending recycled washwater and the raw water for turbidity, $UV_{254}$ and Al removal were lower than that on the raw water. However, TOC removal increased by increasing coagulant dosage. The size and fractal dimension of coagulated particle produced in the blending recycled washwater were larger, which imply faster settling velocity, than those produced in the raw water only.