Ahn, Jung-Hyeon;Moon, Sun-Ae;Moon, Seung-Jae;Lee, Jae-Heon;Yoo, Hoseon
56
In this study, the numerical study has been carried out to analyze the leakage in a steam turbine labyrinth seal. We modified tooth shape of the labyrinth seal and find out the difference of leakage in this study. Original model is straight labyrinth seal and its modified model is slanted labyrinth seal. The numerical analyses are implemented on two models. The numerical results show that each leakage of tooth shape are found to be 0.4781 kg/s and 0.4485 kg/s, respectively. The slanted labyrinth seal confines in a steam better than straight labyrinth seal. Since actual clearance of the stream function in the slant model is smaller than that of the straight model.