Abstract

As a result of analyzing the spectrum using a 1H-NMR spectrometer and a 1H-NMR spectrum prediction program for Visipaque contrast agent, the molecular structure positions in the 2.18 ppm and 2.17 ppm regions were found to be different from each other. The 2.25 ppm and 2.34 ppm regions did not appear in the spectrum analysis using the spectrometer, but did appear in the analysis using the prediction program. In addition, the 2.58 ppm region appeared in the spectrum analysis using the spectrometer, but did not appear in the analysis using the prediction program. The 4.42 ppm region did not appear in the spectrum analysis using the spectrometer, but did appear in the analysis using the prediction program. In addition, the 5.61 ppm region appeared in the spectrum analysis using the spectrometer, but did not appear in the analysis using the prediction program. Based on this, it is thought that if we analyze it using the prediction program as a reference, we will be able to identify the chemical structure more clearly.

Visipaque 조영제 대상으로 1H-NMR Spectrometer를 이용한 스펙트럼 분석과 1H-NMR 스펙트럼 예측 프로그램을 이용하여 분석한 결과, 2.18 ppm영역과 2.17 ppm영역에서 분자구조 위치는 서로 상이하게 나타났다. 2.25 ppm영역과 2.34 ppm영역은 Spectrometer를 이용한 스펙트럼 분석에서는 나타나지 않았고, 예측 프로그램을 이용한 분석에서는 나타났다. 또한 2.58 ppm영역은 Spectrometer를 이용한 스펙트럼 분석에서는 나타났고, 예측 프로그램을 이용하여 분석에서는 나타나지 않았다. 4.42 ppm영역은 Spectrometer를 이용한 스펙트럼 분석에서는 나타나지 않았고, 예측 프로그램을 이용하여 분석에서는 나타났다. 그리고 5.61 ppm영역은 Spectrometer를 이용한 스펙트럼 분석에서는 나타났고, 예측 프로그램을 이용하여 분석에서는 나타나지 않았다. 이를 바탕으로 예측 프로그램을 이용하여 참고로 분석한다면 좀 더 명확한 화학구조를 파악할 수 있을 것으로 사료된다.

Keywords

References

  1. B. H. Han, "Chemical Structure Analysis of Non-ionic Monomer Contrast Agents Using 1H-NMR Spectroscopy", Journal of Radiological Science and Technology, Vol. 44, No. 4, pp. 335-342, 2021. http://dx.doi.org/10.17946/JRST.2021.44.4.335
  2. H. C. Song, H. W. Lim, J. H. Hwa, S. J. Shin, B. S. Kim, Y. O. Kim, Y. S. Kim, E. J. Choi, "Clinical Usefulness of Multi-Detector Computed Tomography in Diagnosis of Patients with Microscopic Hematuria", Kidney Research and Clinical Practice, Vol. 26, No. 2, pp. 155-159. 2007. https://kiss.kstudy.com/Detail/Ar?key=2696212
  3. H. E. Yoon, B. S. Kim, Y. S. Shin, J. H. Hwa, Y. G. Kim, S. J. Shin, Y. O. Kim, H. C. Song, Y. S. Kim, E. J. Choi, "Clinical characteristics of bladder cancer identified by multi-detector computed tomography in patients with asymptomatic isolated hematuria", The Korean Journal of Medicine, Vol. 77, No. 3, pp. 328-332, 2009.
  4. K. E. Jung, J. M. Chung, B. C. Park, K. N. Jee, Y. K. Jee, M. H. Kim, "A Clinical Study of Cutaneous Adverse Reactions to Nonionic Contrast Media in Korea", Annals of Dermatology, Vol. 24, No. 1, pp. 22-25, 2021. http://dx.doi.org/10.5021/ad.2012.24.1.22
  5. Y. M. Park, "Clinical observation and risk factor analysis of CT contrast media side effects that occur during medical examination", Major in Radiological Science Department of Health Technology Convergence The Graduate School of Shinhan University, pp. 3-22,
  6. S. B. Shin, S. J. Jang, N. G. Lee, B. T. Choi, H. K. Shi, "Protective Effects of Traditional Korean Medicine Preparations, Herbs, and Active Compounds on the Blood-brain Barrier in Ischemic Stroke Model" Journal of Life Science, Vol. 32, No. 7, pp. 550-566, 2022. http://dx.doi.org/10.5352/JLS.2022.32.7.550
  7. B. H. Han, "1H-NMR Analysis according to the Storage Period after the Use of Iopamidol and Ioversol Formulations Contrast Agents", Journal of Radiological Science and Technology, Vol. 44, No. 3, pp. 239-245, 2021. http://dx.doi.org/10.17946/JRST.2021.44.3.239
  8. C. Y. Kim, H. J. Kim, M. J. Kim, Y. J. Kang, H. J. Kim, S. H. Chang, D. J. Park, "Allergy Late Adverse Reaction to Iodixanol (Visipaque(R))", The Korean Journal of Medicine, Vol. 81, No. 1, pp. 130-134, 2011.
  9. K. M. Kim, S. M. Im, S. G. Kim, G. T. Oh, G. W. Lee, "Comparative analysis of adverse reactions to different non-ionic contrast media", Journal of Korean Society of Computed Tomographic Technology, Vol. 19, No. 2, pp. 17-26, 2017.
  10. B. H. Han, "Physicochemical Analysis According to Environmental Factors of X-ray Iodinated Contrast Agents", The Graduate School of Hanseo University, Doctor of Health Care, 2020.
  11. S. G. Lee, "The Role of NMR in the Field of Quantitative Analysis", Journal of the Korean Magnetic Resonance Society, Vol. 20 No. 3, pp. 87-94, 2016. http://dx.doi.org/10.6564/JKMRS.2016.20.3.087