DOI QR코드

DOI QR Code

Development of Connector for Solid Precast Concrete Slabs with Diaphragm Action

격막 작용을 갖는 솔리드 프리캐스트 콘크리트 슬래브의 연결장치 개발

  • Lee, Sangsup (Department of Building Research, Korea Institute of Civil Engineering and Building Technology) ;
  • Oh, Keunyeong (Department of Building Research, Korea Institute of Civil Engineering and Building Technology)
  • 이상섭 ;
  • 오근영
  • Received : 2024.06.11
  • Accepted : 2024.07.09
  • Published : 2024.08.20

Abstract

To expedite construction of small precast concrete buildings using dry joints, this study developed and evaluated a connector system for solid slabs. The research included a comprehensive literature review on seismic design requirements for precast concrete floors, followed by an analytical evaluation of the connector's bearing capacity in 3-story buildings. Experimental assessments were conducted to determine the in-plane and out-of-plane capacities of the newly designed semi-circular connector. Finally, the constructability of both the semi-circular and flat connector configurations was compared through tests on single-story precast concrete frames.

이 연구에서는 건식 프리캐스트 콘크리트 공법을 이용해 소형 건축물을 시공 효율을 높이기 위해서 솔리드 슬래브의 연결장치를 개발하였다. 프리캐스트 콘크리트 바닥에 대한 내진설계 요구사항 등을 조사하였고, 3층 소형 건축물의 프리캐스트 콘크리트 바닥 구조의 연결부에 작용하는 부재력을 해석적으로 평가하였다. 개발한 반원형 연결장치의 면내 및 면외 보유 내력을 실험적으로 평가하여 결과를 제시하였다. 단층 프리캐스트 콘크리트 골조를 대상으로 시험 적용을 통해 반원형과 평판형 연결장치의 시공성을 비교하였다.

Keywords

Acknowledgement

Research for this paper was carried out under the KICT Research Program(project no. 20230176-001, Development of Connection Details between Solid Precast Concrete Slabs for Small Buildings / project no. 20240066-001, Planning Research of Modular Construction Research Cluster).

References

  1. KDS 14 20 62. Precast concrete structure design standard. Sejong (Korea): Ministry of Land, Infrastructure and Transport; 2022. 9
  2. ASCE/SEI 7-16. Minimum design loads and associated criteria for buildings and other structures. VA: American Society of Civil Engineers; 2017. p. 135-42.
  3. Prestressed Concrete Institute. PCI design handbook - Precast and prestressed concrete. 8th ed. IL: Precast/Prestressed Concrete Institute; 2017. 885
  4. ACI Committee 318. Building code requirements for reinforced concrete (ACI 318M-19) and commentary. MI: American Concrete Institute; 2019. 628
  5. Architectural Institute of Japan. Guidelines for the design of structural precast concrete emulating cast-in-place reinforced concrete. Tokyo (Japan): Architectural Institute of Japan; 2002. 261
  6. Herlihy MD. Precast concrete floor support and diaphragm action [doctoral Thesis]. [Christchurch (New Zealand)]: University of Canterbury; 1995. 11
  7. NIST. NEHRP seismic design technical brief No.3 seismic design of cast-in-place concrete diaphragms, chords, and collectors. MD: NEHRP; 2016. 29 p. Report No.: NIST GCR 16-917-42.
  8. BCA. Bildable solutions for high-rise residential development. Singapore: Building and Construction Authority; 2004. 115
  9. International Code Council. International building code. washington. DC: International Code Council; 2018. 726
  10. Naito C, Cao L. Precast diaphragm panel joint connector performance. Proceedings 13th World Conference on Earthquake Engineering. 2004 Aug 1-6; Vancouver, Canada. Vancouver (Canada): World Conference on Earthquake Engineering; 2004. p. 1-15.
  11. Hendricks R, Naito C, Osborn A. Flange-to- flange double-tee connections subjected to vehicular Loading. Part 1: Numerical assessment approach. PCI Journal. 2018 Jul-Aug;63(4):41-53. https://doi.org/10.15554/pcij63.4-02
  12. KICT. Development of structural system using a-type precast concrete column for small buildings. Goyang (Korea): Korea Institute of Civil Engineering and Building Technology; 2021. 77 p. Report No.: KICT 2021-052.
  13. KDS 41 17 00. Seismic design code for buildings. Sejong (Korea): Korean Design Standard. Ministry of Land, Infrastructure and Transport. 2019. 125 p.