DOI QR코드

DOI QR Code

Ignition Ability of Flammable Materials by Human Body's Electrostatic Discharge by Type of Fabric

옷감 종류별 인체대전 정전기 방전에 의한 인화성물질 점화능력

  • Jong Soo Hyun (Department of Industrial Safety Engineering, Seoul Digital University)
  • 현종수 (서울디지털대학교 소방안전학부 산업안전공학전공)
  • Received : 2024.02.02
  • Accepted : 2024.03.28
  • Published : 2024.04.30

Abstract

Unwanted effects of electrostatic phenomena occur in various industries. Electrostatic problems originating from the human body in flammable atmospheres in the industry are especially concerning. A substantial volume of experimental data on the electrostatic charging voltages created on the human body owing to the rubbing of apparel were generated and reviewed during this study. The data were reviewed to determine whether the resultant charging levels of the human body are hazardous in flammable atmospheres. This study was conducted under several conditions, such as different fiber types used in apparel, shoe types, and relative humidities (RHs). The following conclusions were drawn in this study. ① The electrostatic charging levels of the human body owing to the rubbing of apparel increase with the increase in the surface resistances of apparel; however, the electrostatic charging levels may be different depending on the condition of the cloth surface. ② The discharging energy of 1.98-18.5 [mJ] from the human body exceeds the minimum ignition energy of most flammable materials, when removing an overcoat made of polyester, cotton and wool under severe conditions such as wearing height-raising shoes for men. ③ When removing antistatic apparel, the maximum discharging energy of 0.128 mJ from the human body is dangerous if the minimum ignition energy of the flammable material is between 10-5-10-4 [J] Grade; however, a minimum ignition energy of 10-3 J Grade of the flammable material is considered safe. ④ While wearing antistatic shoes, the electrostatic charging voltage generated in the human body when removing an overcoat is 30 V; therefore, wearing such shoes is a suitable countermeasure when handling flammable materials. However, the antistatic abilities of shoes reduce when thick socks are worn. ⑤ As RH increases, the electrostatic charging levels of the human body decrease. ⑥ The electrostatic charging levels of the human body from removing a cotton overcoat can ignite the majority of flammable materials when RH is less than 30% under severe conditions such as wearing height-raising shoes for men.

Keywords

References

  1. T. Kitagawa et al., "Safety Engineering Course 2 - Explosion", Safety Engineering Association, pp. 247-248, 1983.
  2. M. Naito, Fire and Explosion Science, Japan Industrial Safety & Health Association, pp. 66-68, 1987.
  3. Y. S. Lee, Essential Safety and Safety Equipment", Korea Industrial Safety Device Manufacturing Association, Seminar on Safety Measures for Chemical Plant Improvement, pp. 7-59, 1997.
  4. L. Fukuyama, Fire Explosion.Mechanical Materials Edition-Safety Engineering Experiment Method, Nikkan Industrial Newspaper, pp. 231-234, 1983.
  5. Electrostatic Handbook, The Institute of Electrostatics Japan, p. 133, p. 282, p. 322, 1998.
  6. D. C. Lee and J. H. Chung, "Prevention of Electrostatic Disasters and Disruptions throughout the Industry", Sungandang, pp. 37-39, p. 78, 1996.
  7. Y. M. Chang et al., "A Study on the Electrostatic Characteristics of the Materials Treated by Antistatic Additives", J. Korean Soc. Saf., Vol. 10, No. 1, pp. 20-27, 1995.
  8. S. W. Choi et al., "A Study on the Improvement Plan of Electrostatic Safety Management Level through Injury Analysis", J. Korean Soc, Saf,, Vol. 34, No. 5, pp. 37-45, 2019.
  9. N. S. Kim and D. J. Park, "Experimental Investigations on Explosion Characteristics of LPG/Air Mixture by Electrostatic Discharge Energies", J. Korean Soc. Saf., Vol. 26, No. 6, pp. 26-30, 2011.
  10. G. H. Lee and J. H. Chung, A Study on the Safety Management of the Electrostatic in Working Clothes at the Gas Station", J. Korean Soc. Saf., Vol. 24, No. 6, pp. 39-44, 2009.
  11. Japan LP Gas Association, LP Gas Technology Overview, KIBODANG, Japan, p. 796, 1981.
  12. J. S. Chang, A. J. Kelly and J. M. Crowley, Handbook of Electrostatic Process, Marcel Dekker, Inc., New York, pp. 703-722, 1995.
  13. B. G. Son and J. D. Moon, Contact Electrification of Some Polymeric Solid Dielectric Materials with Mercury, Industrial Development Institute of Kyungpook National University, The Research Report Vol. 3, pp. 84-89, 1975.
  14. Y. S. Seo and J. D. Moon, "Frictional Electricity of Polyester Blended Fiber", Industrial Development Institute of Kyungpook National University, The Research Report Vol. 4, pp. 37-42, 1976.
  15. H. Marumo, Antistatic Agent, SAIWAI SHOBO, Tokyo, 1972.
  16. J. W. S. Hearle, "11-The Electrical Resistance of Textile Materials : I. The Influence of Moisture Content", Journal of the Textile Institute Transactions, Vol. 44, Issue 4, p. T117, 1953.
  17. Y. J. Oh, "A Study on the Generation of Electrostatic by the Type of Fiber", Industrial Arts and Applied Design Major, Master's Thesis, Sungshin Women's University Graduate School, 1992.