Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study

  • Young Woo Song (Department of Periodontology, Dental Hospital, Veterans Health Service Medical Center) ;
  • Seung Ha Yoo (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry) ;
  • Ui-Won Jung (Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry)
  • Received : 2023.10.18
  • Accepted : 2024.02.06
  • Published : 2024.02.29

Abstract

PURPOSE. The present experiment aimed to evaluate the placement accuracy of fully guided implant surgery using a mucosa-supported surgical guide when the protocol of osteotomy and installation was modified (MP) compared to when the protocol was sequentially and conventionally carried out (CP). MATERIALS AND METHODS. For 24 mandibular dentiform models, 12 dentists (6 experts and 6 beginners) performed fully guided implant placements two times at the right first and second molar sites using a mucosa-supported surgical guide, once by the CP (CP group) and at the other time by the MP (MP group). The presurgical and postsurgical stereolithographic images were superimposed, and the deviations between the virtually planned and actually placed implant positions and the procedure time were compared statistically (P < .05). RESULTS. The accuracies were similar in the CP and MP groups. In the CP group, the mean platform and apex deviations at the second molar site for the beginners were +0.75 mm and +1.14 mm, respectively, which were significantly larger than those for the experts (P < .05). In the MP group, only the mean vertical deviation at the second molar site for the beginners (+0.53 mm) was significantly larger than that for the experts (P < .05). The procedure time was significantly longer for the MP group (+94.0 sec) than for the CP group (P < .05). CONCLUSION. In fully guided implant surgery using a mucosa-supported guide, the MP may improve the placement accuracy when compared to the CP, especially at sites farther from the most-posterior natural tooth.

Keywords

Acknowledgement

We are very grateful to the 12 periodontal residents of Yonsei University Dental Hospital who participated in this research.

References

  1. D'haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A. Current state of the art of computer-guided implant surgery. Periodontol 2000 2017;73:121-33. https://doi.org/10.1111/prd.12175
  2. Park JY, Song YW, Park SH, Kim JH, Park JM, Lee JS. Clinical factors influencing implant positioning by guided surgery using a nonmetal sleeve template in the partially edentulous ridge: Multiple regression analysis of a prospective cohort. Clin Oral Implants Res 2020;31:1187-98. https://doi.org/10.1111/clr.13664
  3. Song YW, Park JY, Jung JY, Kim JN, Hu KS, Lee JS. Does the fixture thread depth affect the accuracy of implant placement during fully guided immediate implant placement?: A human cadaver study. Clin Oral Implants Res 2023;34:116-26. https://doi.org/10.1111/clr.14023
  4. Cassetta M, Giansanti M, Di Mambro A, Stefanelli LV. Accuracy of positioning of implants inserted using a mucosa-supported stereolithographic surgical guide in the edentulous maxilla and mandible. Int J Oral Maxillofac Implants 2014;29:1071-8. https://doi.org/10.11607/jomi.3329
  5. Verhamme LM, Meijer GJ, Soehardi A, Berge SJ, Xi T, Maal TJJ. An accuracy study of computer-planned implant placement in the augmented maxilla using osteosynthesis screws. Int J Oral Maxillofac Surg 2017;46:511-7. https://doi.org/10.1016/j.ijom.2016.10.013
  6. Van Assche N, Vercruyssen M, Coucke W, Teughels W, Jacobs R, Quirynen M. Accuracy of computer-aided implant placement. Clin Oral Implants Res 2012;23 Suppl 6:112-23. https://doi.org/10.1111/j.1600-0501.2012.02552.x
  7. Zhou W, Liu Z, Song L, Kuo CL, Shafer DM. Clinical factors affecting the accuracy of guided implant surgery-a systematic review and meta-analysis. J Evid Based Dent Pract 2018;18:28-40. https://doi.org/10.1016/j.jebdp.2017.07.007
  8. Matsumura A, Nakano T, Ono S, Kaminaka A, Yatani H, Kabata D. Multivariate analysis of causal factors influencing accuracy of guided implant surgery for partial edentulism: a retrospective clinical study. Int J Implant Dent 2021;7:28.
  9. Orgev A, Pellerito J, Polido W, Morton D, Lin WS. Bead-anchored surgical templates for static computer-assisted implant surgery: A dental technique. J Prosthodont 2022;31:722-7. https://doi.org/10.1111/jopr.13566
  10. Kalpidis CD, Setayesh RM. Hemorrhaging associated with endosseous implant placement in the anterior mandible: a review of the literature. J Periodontol 2004;75:631-45. https://doi.org/10.1902/jop.2004.75.5.631
  11. Song YW, Kim J, Kim JH, Park JM, Jung UW, Cha JK. Accuracy of dental implant placement by a novel inhouse model-free and zero-setup fully guided surgical template made of a light-cured composite resin (VARO Guide®): a comparative in vitro study. Materials (Basel) 2021;14:4023.
  12. Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 2014;29 Suppl:25-42. https://doi.org/10.11607/jomi.2014suppl.g1.2
  13. Vasak C, Watzak G, Gahleitner A, Strbac G, Schemper M, Zechner W. Computed tomography-based evaluation of template (NobelGuideTM)-guided implant positions: a prospective radiological study. Clin Oral Implants Res 2011;22:1157-63. https://doi.org/10.1111/j.1600-0501.2010.02070.x
  14. Arisan V, Karabuda ZC, Ozdemir T. Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. J Periodontol 2010;81:43-51. https://doi.org/10.1902/jop.2009.090348
  15. Cassetta M, Stefanelli LV, Giansanti M, Di Mambro A, Calasso S. Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide. Int J Oral Maxillofac Surg 2011;40:1377-87. https://doi.org/10.1016/j.ijom.2011.09.009
  16. Cassetta M, Stefanelli LV, Giansanti M, Di Mambro A, Calasso S. Accuracy of a computer-aided implant surgical technique. Int J Periodontics Restorative Dent 2013;33:317-25. https://doi.org/10.11607/prd.1019
  17. D'haese J, Van De Velde T, Elaut L, De Bruyn H. A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae. Clin Implant Dent Relat Res 2012;14:293-303. https://doi.org/10.1111/j.1708-8208.2009.00255.x
  18. Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol 2005;76:503-7. https://doi.org/10.1902/jop.2005.76.4.503
  19. Cho UH, Yu W, Kyung HM. Root contact during drilling for microimplant placement. Affect of surgery site and operator expertise. Angle Orthod 2010;80:130-6. https://doi.org/10.2319/011509-535.1
  20. Cushen SE, Turkyilmaz I. Impact of operator experience on the accuracy of implant placement with stereolithographic surgical templates: an in vitro study. J Prosthet Dent 2013;109:248-54. https://doi.org/10.1016/S0022-3913(13)60053-0
  21. Marei HF, Abdel-Hady A, Al-Khalifa K, Al-Mahalawy H. Influence of surgeon experience on the accuracy of implant placement via a partially computer-guided surgical protocol. Int J Oral Maxillofac Implants 2019;34:1177-83. https://doi.org/10.11607/jomi.7480
  22. Sicilia A, Botticelli D; Working Group 3. Computer-guided implant therapy and soft- and hard-tissue aspects. The Third EAO Consensus Conference 2012. Clin Oral Implants Res 2012;23 Suppl 6:157-61. https://doi.org/10.1111/j.1600-0501.2012.02553.x
  23. Van de Wiele G, Teughels W, Vercruyssen M, Coucke W, Temmerman A, Quirynen M. The accuracy of guided surgery via mucosa-supported stereolithographic surgical templates in the hands of surgeons with little experience. Clin Oral Implants Res 2015;26:1489-94. https://doi.org/10.1111/clr.12494
  24. Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis. Clin Oral Implants Res 2018;29 Suppl 16:416-35. https://doi.org/10.1111/clr.13346
  25. Chen Z, Li J, Sinjab K, Mendonca G, Yu H, Wang HL. Accuracy of flapless immediate implant placement in anterior maxilla using computer-assisted versus freehand surgery: A cadaver study. Clin Oral Implants Res 2018;29:1186-94. https://doi.org/10.1111/clr.13382
  26. Tahmaseb A, De Clerck R, Aartman I, Wismeijer D. Digital protocol for reference-based guided surgery and immediate loading: a prospective clinical study. Int J Oral Maxillofac Implants 2012;27:1258-70.
  27. Younes F, Cosyn J, De Bruyckere T, Cleymaet R, Bouckaert E, Eghbali A. A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. J Clin Periodontol 2018;45:721-32. https://doi.org/10.1111/jcpe.12897
  28. Castillo-de-Oyague R, Sanchez-Turrion A, Lopez-Lozano JF, Albaladejo A, Torres-Lagares D, Montero J, Suarez-Garcia MJ. Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents. Med Oral Patol Oral Cir Bucal 2012;17:e610-7. https://doi.org/10.4317/medoral.17997
  29. Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-6.