DOI QR코드

DOI QR Code

A study on the seismic behavior of Reinforced Concrete (RC) wall piers strengthened with CFRP sheets: A pushover analysis approach

  • Received : 2022.12.31
  • Accepted : 2023.11.13
  • Published : 2023.12.10

Abstract

The use of reinforced concrete (RC) shear walls (SW) as an efficient lateral load-carrying system has gained recent attention. However, creating openings in RC shear walls is unavoidable due to architectural requirements. This reduces the walls' strength and stiffness, resulting in the development of wall piers. In this study, the cyclic behavior of RC shear walls with openings, reinforced with carbon fiber reinforced polymer (CFRP) sheets in various patterns, was numerically investigated. Finite element analysis (FEA) using ABAQUS software was employed. Additionally, the retrofitting of sub-standard buildings (5, 10, and 15-story structures) designed based on the old and new versions of the Iranian Code of Practice for Seismic-Resistant Structures was evaluated. Nonlinear static analyses, specifically pushover analyses, were conducted on the structures. The best pattern of CFRP wrapping was determined and utilized for retrofitting the sub-standard structures. Various structural parameters, such as load-carrying capacity, ductility, stress contours, and tension damage contours, were compared to assess the efficiency of the retrofit solution. The results indicated that the load-carrying capacity of the sub-standard structures was lower than that of standard ones by 57%, 69%, and 67% for 5, 10, and 15-story buildings, respectively. However, the retrofit solution utilizing CFRP showed promising results, enhancing the capacity by 10-25%. The retrofitted structures demonstrated increased yield strength, ultimate strength, and ductility through CFRP wrapping and effectively prevented wall slipping.

Keywords

References

  1. ACI Committee 318 (2014), Building Code Requirements for Structural Concrete (ACI318-14) and Commentary.
  2. ACI Committee 374.2R (2013), Guide for Testing Reinforced Concrete Structural Elements under Slowly Applied Simulated Seismic Loads, American Concrete Institute.
  3. Ali, A. and Wight, J.K. (1991), "RC structural walls with staggered door openings", J. Struct. Eng., 117(5), 1514-1531. https://doi.org/10.1061/(ASCE)0733-9445(1991)117:5(1514).
  4. Altin, S., Anil, O., Kopraman, Y. and Kara, M.E. (2013), "Hysteretic behavior of RC shear walls strengthened with CFRP strips", Compos. Part B: Eng., 44(1), 321-329. https://doi.org/10.1016/j.compositesb.2012.05.009.
  5. Aslani, K. and Kohnehpooshi, O. (2018), "Structural behavior of FRP-strengthened reinforced concrete shear walls with openings using finite element method", Adv. Struct. Eng., 21(7), 1072-1087. https://doi.org/10.1177/1369433217737121.
  6. ASTM E2126-11 (2018), Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Walls, ASTM E2126-11.
  7. Behfarnia, K. and Shirneshan, A. (2017), "A numerical study on behavior of CFRP strengthened shear wall with opening", Comput. Concrete, 19(2), 179-189. https://doi.org/10.12989/cac.2017.19.2.179.
  8. Deng, K., Pan, P., Shen, S., Wang, H. and Feng, P. (2018), "Experimental study of FRP-reinforced slotted RC shear walls under cyclic loading", J. Compos. Constr., 22(4), 4018017. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000855.
  9. El-Kashif, K.F.O., Adly, A.K. and Abdalla, H.A. (2019), "Finite element modeling of RC shear walls strengthened with CFRP subjected to cyclic loading", Alex. Eng. J., 58(1), 189-205. https://doi.org/10.1016/j.aej.2019.03.003.
  10. FEMA 273 (1997), NEHRP Guidelines for the Seismic Rehabilitation of Buildings.
  11. Han, Q., Wang, D., Zhang, Y., Tao, W. and Zhu, Y. (2020), "Experimental investigation and simplified stiffness degradation model of precast concrete shear wall with steel connectors", Eng. Struct., 220, 110943. https://doi.org/10.1016/j.engstruct.2020.110943.
  12. Honarparast, S. and Chaallal, O. (2019), "Non-linear time history analysis of reinforced concrete coupled shear walls: Comparison of old design, modern design and retrofitted with externally bonded CFRP composites", Eng. Struct., 185, 353-365. https://doi.org/10.1016/j.engstruct.2019.01.113.
  13. Honarparast, S. and Chaallal, O. (2022), "Seismic performance of coupled shear walls designed according to old and new codes and retrofitted with Eb-CFRP composites", J. Earthq. Eng., 26(4), 1875-1898. https://doi.org/10.1080/13632469.2020.1743387.
  14. Hosseini, S.A., Kheyroddin, A. and Mastali, M. (2019), "An experimental investigation into the impacts of eccentric openings on the in-plane behavior of squat RC shear walls", Eng. Struct., 197, 109410. https://doi.org/10.1016/j.engstruct.2019.109410.
  15. Husain, M., Eisa, A.S. and Hegazy, M.M. (2019), "Strengthening of reinforced concrete shear walls with openings using carbon fiber-reinforced polymers", Int. J. Adv. Struct. Eng., 11(2), 129-150. https://doi.org/10.1007/S40091-019-0216-6/TABLES/8.
  16. Jiang, H., Wang, B. and Lu, X. (2013), "Experimental study on damage behavior of reinforced concrete shear walls subjected to cyclic loads", J. Earthq. Eng., 17(7), 958-971. https://doi.org/10.1080/13632469.2013.791895.
  17. Kheyroddin, A. and Emami, E. (2016), Shear Walls, 1st Edition, Semnan University.
  18. Kheyroddin, A. and Naderpour, H. (2008), Nonlinear Finite Element Analysis of Composite RC Shear Walls.
  19. Kheyroddin, A. and Sharbatdar, M.K. (2016), Retrofitting Reinforced Concrete Structures with Steel Plates and FRP Composite, 1st Editiom, Semnan University.
  20. Li, B. and Lim, C.L. (2010), "Tests on seismically damaged reinforced concrete structural walls repaired using fiber-reinforced polymers", J. Compos. Constr., 14(5), 597-608. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000110.
  21. Lima, M.M., Doh, J.H. and Hadi, M.N.S. (2019), "Experimental study on RC walls with opening strengthened by externally bonded CFRP", J. Compos. Constr., 23(2), 4019008. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000930.
  22. Lima, M.M., Doh, J., Hadi, M.N.S. and Miller, D. (2016), "The effects of CFRP orientation on the strengthening of reinforced concrete structures", Struct. Des. Tall Spec. Build., 25(15), 759-784. https://doi.org/10.1002/tal.1282.
  23. Lombard, J.C. (1999), Seismic Strengthening and Repair of Reinforced Concrete Shear Walls using Externally Bonded Carbon Fibre Tow Sheets, Carleton University.
  24. Mamdouh, H., Zenhom, N., Hasabo, M., Deifalla, A. F. and Salman, A. (2022), "Performance of strengthened, reinforced concrete shear walls with opening", Sustain., 14(21), 14366. https://doi.org/10.3390/SU142114366.
  25. Marius, M. (2013), "Seismic behaviour of reinforced concrete shear walls with regular and staggered openings after the strong earthquakes between 2009 and 2011", Eng. Fail. Anal., 34, 537-565. https://doi.org/10.1016/j.engfailanal.2013.05.014.
  26. Mosoarca, M. (2014), "Failure analysis of RC shear walls with staggered openings under seismic loads", Eng. Fail. Anal., 41, 48-64. https://doi.org/10.1016/j.engfailanal.2013.07.037.
  27. Mosoarca, M. and Stoian, V. (2012), "Seismic energy dissipation in structural reinforced concrete walls with staggered openings", J. Appl. Eng. Sci. JAES, 2(15), 71-78.
  28. Mostofinejad, D. and Mohammadi Anaei, M. (2012), "Effect of confining of boundary elements of slender RC shear wall by FRP composites and stirrups", Eng. Struct., 41, 1-13. https://doi.org/10.1016/j.engstruct.2012.03.019.
  29. Pachideh, G. and Gholhaki, M. (2020), "Evaluation of concrete filled steel tube column confined with FRP", J. Test. Eval., 48(6), 4343-4354. https://doi.org/10.1520/JTE20180148.
  30. Popescu, C., Sas, G., Sabau, C. and Blanksvard, T. (2016), "Effect of cut-out openings on the axial strength of concrete walls", J. Struct. Eng., 142(11), 4016100. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001558.
  31. Todut, C., Dan, D., Stoian, V. and Fofiu, M. (2023), "Theoretical and experimental study of damaged reinforced concrete shear walls strengthened with FRP composites", Compos. Struct., 313, 116912. https://doi.org/10.1016/j.compstruct.2023.116912.
  32. Wang, J., Sakashita, M., Kono, S. and Tanaka, H. (2012), "Shear behaviour of reinforced concrete structural walls with eccentric openings under cyclic loading: experimental study", Struct. Des. Tall Spec. Build., 21(9), 669-681. https://doi.org/10.1002/tal.639.
  33. Wang, J., Sakashita, M., Kono, S., Tanaka, H. and Lou, W. (2010), "Behavior of reinforced concrete structural walls with various opening locations: Experiments and macro model", J. Zhejiang Univ. Sci. A, 11(3), 202-211. https://doi.org/10.1631/jzus.A0900400.