DOI QR코드

DOI QR Code

Response of transmission line conductors under different tornadoes

  • Dingyu Yao (Research Centre for Wind Engineering, Southwest Jiaotong University) ;
  • Ashraf El Damatty (Research Centre for Wind Engineering, Southwest Jiaotong University) ;
  • Nima Ezami (Research Centre for Wind Engineering, Southwest Jiaotong University)
  • 투고 : 2022.10.16
  • 심사 : 2023.05.06
  • 발행 : 2023.09.25

초록

Multiple studies conducted in the past evaluated the conductor response under one tornado wind field, while the performance of transmission lines under different tornado wind fields still remains unknown. Thus, the objective of this paper is to estimate the variation in the conductor's critical longitudinal and transverse reactions under different tornado wind fields, as well as providing the corresponding critical tornado configurations. The considered full-scale tornadoes are the Spencer, South Dakota, 1998, the Stockton, Kansas, 2005 and the Goshen County, Wyoming, 2009. Computational Fluid Dynamics (CFD) simulations were previously conducted to develop these wind fields. All tornadoes have been rescaled to have a common velocity matching the upper limit of the F2 Fujita scale. Eight conductor systems, each including six spans, are considered in this paper. For each conductor, parametric studies are conducted by varying the location of the three tornado wind fields relative to the tower of interest, therefore the peak reactions associated with each tornado are determined. A semi-analytical closed-form solution, previously developed and validated, is used to calculate the reactions. The study conducted in this paper can be divided into two parts: In the first part, a parametric study considering a wide range of tornado locations is conducted. In the second part, the parametric study focuses on the tornado location leading to the critical tangential velocity on the tower. Based on this extensive parametric study, a critical tornado defined as the Design Tornado and its critical locations, tornado distance R = 125 m, tornado angle 𝜃 = 15° and 30°, are recommended for design purposes.

키워드

과제정보

The authors gratefully acknowledge the Natural Sciences and Engineering Research Council of Canada (NSERC) and Hydro One Company for their kind financial support of this research.

참고문헌

  1. Aboshosha, H. and El Damatty, A. (2014), "Effective technique to analyze transmission line conductors under high intensity winds", Wind Struct., 18(3), 235-252. https://doi.org/10.12989/was.2014.18.3.235.
  2. Altalmas, A. and El Damatty, A. (2014), "Finite element modelling of self-supported transmission lines under tornado loading", Wind Struct., 18(5), 473-495. https://doi.org/10.12989/was.2014.18.5.473.
  3. Alipour, A., Sarkar, P., Dikshit, S., Razavi, A. and Jafari, M. (2020), "Analytical approach to characterize tornado-induced loads on lattice structures", J. Struct. Eng., 146(6), 04020108. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002660.
  4. Darwish, M.M., El Damatty, A. and Hangan, H. (2010), "Dynamic characteristics of transmission line conductors and behaviour under turbulent downburst loading", Wind Struct., 13(4), https://doi.org/10.12989/was.2010.13.4.327.
  5. Dempsey, D. and White, H. (1996), "Winds wreak havoc on lines", Transm. Distribut. World, 48, 32-37.
  6. El Damatty, A. and Hamada, A. (2016), "F2 tornado velocity profiles critical for transmission line structures", Eng. Struct., 106, 436-449, https://doi.org/10.1016/j.engstruct.2015.10.020.
  7. El Damatty, A., Hamada, M. and Hamada, A. (2015), "Simplified F2-Tornado load cases for transmission line structures", In 14th International Conference on Wind Engineering, Porto Alegre, Brazil.
  8. Fujita, T.T. (1981) "Tornadoes and downbursts in the context of generalized planetary scales", J. Atmos. Sci., 38(8), 1511-1534. https://doi.org/10.1175/15200469(1981)038<1511:TADITC>2.0.CO;2.
  9. Fujita, T.T. and Pearson, A.D. (1973), "Results of FPP classification of 1971 and 1972 tornadoes", In Eight conference on severe local storms, 142-145, Denver, CO, USA, October.
  10. GB50545-2010 (2010), Code For Design Of 110kV~750kV Overhead Transmission Line, China.
  11. Gerges, R.R. & El-Damatty, A. (2002), "Large displacement analysis of curved beams", In Proceeding of CSCE Conference, Montreal, QC, Canada, ST.
  12. Hamada, A. and El Damatty, A. (2011), "Behaviour of guyed transmission line structures under tornado wind loading", Comput. Struct., 89(11-12), 986-1003. https://doi.org/10.1016/j.compstruc.2011.01.015.
  13. Hamada, A. and El Damatty, A. (2015), "Failure analysis of guyed transmission lines during F2 tornado event", Eng. Struct., 85(2), 11-25. https://doi.org/10.1016/j.engstruct.2014.11.045.
  14. Hamada, A. and El Damatty. A. (2016) "Behaviour of transmission line conductors under tornado wind", Wind Struct., 22(3), 369-391. https://doi.org/10.12989/was.2016.22.3.369.
  15. Hangan, H. and Kim, J. (2008), "Swirl ratio effects on tornado vortices in relation to the Fujita scale", Wind Struct., 11(4), 291-302. https://doi.org/10.12989/was.2008.11.4.291.
  16. Holmes, J.D., Hangan, H.M., Schroeder, J., Letchford, D. and Orwig, K.D. (2008), "A forensic study of the Lubbock-Reese downdraft of 2002", Wind Struct., 11(2), 137-152. https://doi.org/10.12989/was.2008.11.2.137.
  17. Ishac, M.F. and White, H.B. (1994), "Effect of tornado loads on transmission lines", In Proceedings of IEEE/PES Transmission and Distribution Conference, 521-527. IEEE.
  18. Nima, E., Ahmed, H. and Mohamed, H. (2022), "The effect of different tornado wind fields on the response of transmission line structures", Wind Struct., 34(2), 512-230. https://doi.org/10.12989/was.2022.34.2.512.
  19. Refan, M., Hangan, H. amd Wurman, J. (2014), "Reproducing tornadoes in laboratory using proper scaling", J. Wind Eng. Ind. Aerod., 135(13), 136-148. https://doi.org/10.1016/j.jweia.2014.10.008.
  20. Savory, E., Parke, G.A., Zeinoddini, M., Toy, N. and Disney, P. (2001), "Modelling of tornado and microburst-induced wind loading and failure of a lattice transmission tower", Eng. Struct., 23(4), 365-375. https://doi.org/10.1016/S0141-0296(00)00045-6.
  21. Shehata, A., El Damatty, A. and Savory, E. (2005), "Finite element modeling of transmission line under downburst wind loading", Finite Element. Anal. Des., 42(1), 71-89. https://doi.org/10.1016/j.finel.2005.05.005.
  22. Wurman, J. (1998), "Preliminary results from the ROTATE-98 tornado study", In 19th Conference on Severe Local Storms. Minneapolis, MN, USA.
  23. Yong, W. and Lingyi, L. (2017), "One-way fluid-structure interaction analysis of transmission tower under tornado loading", Spec. Struct., 153(02), 13-19.
  24. Zhang, Y. (2006), "Status quo of wind hazard prevention for transmission lines and countermeasures", East China Electric Power, 34(3), 28-31.