Abstract

In this study, a double wall system is introduced, which was invented to simplify the complicated manufacturing process of the existing precast concrete (PC) double wall systems and to remove defects such as laitance that may occur during the production of concrete panels. An experimental study was conducted to investigate the tensile resisting capacity of the steel tube which is embedded in the precast concrete panel to keep the spacing between PC panels and to prevent damage of the PC panels during transportation and casting concrete onsite. The experiment was planned to determine the detail of effective steel tube connection considering the steel plate treatment method according to the formation of the opening, the presence of embedded concrete, and the reinforcement welding for additional dowel action as key variables. As a result, the ultimate tensile strength increased by 20-30% compared to the control specimen (ST) except for the steel tube specimen (ST_CP) which has steel plates bent inward at the end part of the steel tube. Since the specimen (ST_CON) filled with concrete inside the control specimen has no additional process and cost for the steel tube connections compared to the control specimen during the production of the developed double wall system, it is determined to be the appropriate detail of steel tube connection.

이 연구에서는 기존 프리캐스트 콘크리트 (Precast concrete, PC) 더블월 시스템의 복잡한 제작 공정을 간소화하면서 콘크리트 패널 형성 시 발생할 수 있는 레이턴스 등의 결함을 제거하고자 고안된 새로운 PC 더블월 공법을 소개하고 이때, PC 패널이 운반 또는 현장 콘크리트 타설 시 손상되지 않고 간격을 유지하는 역할을 하는 각형 강관에 대한 인장저항 성능을 규명하기 위한 실험적 연구를 수행하였다. 각형 강관의 단부 상세를 변수로 인장실험을 계획하였으며 개구부 형성에 따른 강판의 처리방법, 매립 콘크리트의 존치 유무, 추가적인 장부작용 확보를 위한 철근용접 등을 변수로 설정하여 효과적인 강관 단부 상세를 도출하고자 하였다. 결과적으로, 강관 단부의 측면을 절개한 강판을 강관 단부 방향 안쪽으로 절곡한 강관 실험체 (ST_CP)를 제외하고 기준실험체 (ST)에 비하여 20~30% 가량 증가한 최대 인장강도를 나타내었다. 기준실험체 내부에 콘크리트를 채운 실험체 (ST_CON)가 PC 더블월 제작 시 구성되는 각형 강관 연결부와 유사한 상세를 가지며 추가적인 시공과정과 비용이 요구되지 않으므로 가장 적합한 연결상세인 것으로 판단된다.

Keywords

Acknowledgement

이 논문은 정부(과학기술정보통신부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구임(No. 2021R1C1C2093437). 또한, 원피씨엔지니어링의 연구개발 지원에도 감사드립니다.

References

  1. Choi, H. B., Kim, H. S., Seo, D. S., and Kang, K. I. (2003), The Study on the Capability Transform and Alternative Plan of Reinforcing Bar with Straightening after Bending, Journal of the Architectural Institute of Korea, 19(9), 181-188.
  2. Ji, K. H., and Choi, B. J. (2019), Improvement of Underground Wall Design and Construction Safety Using Mega Double Wall Construction Method, Journal of the Korean Society of Hazard Mitigation, 19(1), 1-12. https://doi.org/10.9798/KOSHAM.2019.19.1.1
  3. Jiang, J., Luo, J., Xue, W., Hu, X., and Qin, D. (2022), Experimental study on Hysteresis Behavior of Precast Concrete Double Skin Shear Wall with Horizontal Loop Connection and Spiral-confined Vertical Lap Connection, Journal of Building Engineering, 45, 103526.
  4. KDS 14 20 54 (2021), Standard for Durability Design of Concrete Structures, Korea Concrete Institute, Korea.
  5. KS B 1002 (2021), Hexagon Head Bolts and Hexagon Head Screws, Korea Agency for Technology and Standards, Korea.
  6. KS D 3568 (2018), Carbon Steel Square Pipes for General Structural Purposes, Korea Agency for Technology and Standards, Korea.
  7. Kim, S., Lee, D. E., Kim, Y., and Kim, S. (2020), Development and Application of Precast Concrete Double Wall System to Improve Productivity of Retaining Wall Construction. Sustainability, 12(8), 3454.
  8. Lee, W. J., Kim, M., Lee, D., Ju, H., and Kim, K. H. (2022), Seismic Performance Evaluation of Intermediate Precast Structural Walls, The Journal of Next-generation Convergence Technology Association, 6(3), 421-432. https://doi.org/10.33097/JNCTA.2022.06.03.421
  9. Oh, Y. H., Moon, J. H., Kim, J. K., Lee, J. H., and Shin, S. H. (2020), Evaluation of Structural Performance for Precast Concrete Double-wall with Different Aspect Ratios and Joint Rebar Ratios, Journal of the Korea Concrete Institute, 32(5), 445-455. https://doi.org/10.4334/JKCI.2020.32.5.445
  10. Park, Y. S. (2021), PC DW: Precast Double Wall, 3SW: Stable, Strong, Sustainable, Magazine of the Korea Concrete Institute, 33(5), 59-61.