Hybrid vibration-impedance monitoring in prestressed concrete structure with local strand breakage

  • Dang, Ngoc-Loi (Urban Infrastructure Faculty, Mien Tay Construction University) ;
  • Pham, Quang-Quang (Department of Ocean Engineering, Pukyong National University) ;
  • Kim, Jeong-Tae (Department of Ocean Engineering, Pukyong National University)
  • 투고 : 2022.04.11
  • 심사 : 2022.08.22
  • 발행 : 2022.11.25

초록

In this paper, a hybrid vibration-impedance-based damage monitoring approach is experimentally evaluated for prestressed concrete (PSC) structures with local strand breakage. Firstly, the hybrid monitoring scheme is designed to alert damage occurrence from changes in vibration characteristics and to localize strand breakage from changes in impedance signatures. Secondly, a full-scale PSC anchorage is experimented to measure global vibration responses and local impedance responses under a sequence of simulated strand-breakage events. Finally, the measured data are analyzed using the hybrid monitoring framework. The change of structural condition (i.e., damage extent) induced by the local strand breakage is estimated by changes in a few natural frequencies obtained from a few accelerometers in the structure. The damaged strand is locally identified by tomography analysis of impedance features measured via an array of PZT (lead-zirconate-titanate) sensors mounted on the anchorage. Experimental results demonstrate that the strand breakage in the PSC structure can be accurately assessed by using the combined vibration and impedance features.

키워드

과제정보

This work was supported by a grant (21CTAP-C163708-01) from the Technology Advancement Research Program funded by Korea Agency for Infrastructure Technology Advancement (KAIA).

참고문헌

  1. Abdulkarem, M., Samsudin, K., Rokhani, F.Z. and A Rasid, M.F. (2019), "Wireless sensor network for structural health monitoring: A contemporary review of technologies, challenges, and future direction", Struct. Health Monitor., 19(3), 693-735. https://doi.org/10.1177/1475921719854528
  2. Abdullah, A.B.M., Rice, J.A. and Hamilton, H.R. (2015a), "A strain-based wire breakage identification algorithm for unbonded PT tendons", Smart Struct. Syst., Int. J., 16(3), 415-433. https://doi.org/10.12989/sss.2015.16.3.415
  3. Abdullah, A.B.M., Rice, J.A. and Hamilton, H.R. (2015b), "Wire breakage detection using relative strain variation in unbonded posttensioning anchors", J. Bridge Eng., 20(1), 1-12. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000639
  4. Ai, D., Luo, H. and Zhu, H. (2019), "Numerical and experimental investigation of flexural performance on pre-stressed concrete structures using electromechanical admittance", Mech. Syst. Signal Process., 128, 244-265. https://doi.org/10.1016/j.ymssp.2019.03.046
  5. Bhalla, S. and Soh, C.K. (2004), "Electromechanical Impedance Modeling for Adhesively Bonded Piezo-Transducers", J. Intell. Mater. Syst. Struct., 15(12), 955-972. https://doi.org/10.1177/1045389X04046309
  6. Bonopera, M., Chang, K.C. and Lee, Z.K. (2020), "State-of-the-art review on determining prestress losses in prestressed concrete girders", Appl. Sci., 10(20), p. 7257. https://doi.org/10.3390/app10207257
  7. Brincker, R., Zhang, L. and Andersen, P. (2001), "Modal identification of output-only systems using frequency domain decomposition", Smart Mater. Struct., 10(3), p. 441. https://doi.org/10.1088/0964-1726/10/3/303
  8. Cervenka, V. and Ganz, H.R. (2014), "Validation of posttensioning anchorage zones by laboratory testing and numerical simulation", Struct. Concrete, 15(2), 258-268. https://doi.org/10.1002/suco.201300038
  9. Cho, S., Lynch, J.P., Lee, J.J. and Yun, C.B. (2009), "Development of an automated wireless tension force estimation system for cable-stayed bridges", J. Intell. Mater. Syst. Struct., 21(3), 361-376. https://doi.org/10.1177/1045389X09350719
  10. Clough, R. and Penzien, J. (1995), Dynamics of Structures, (3rd Edition), Computers & Structures, Inc., University Ave, Berkeley, CA, USA.
  11. Dang, N.L., Huynh, T.C. and Kim, J.T. (2019), "Local strandbreakage detection in multi-strand anchorage system using an impedance-based stress monitoring method-feasibility study", Sensors, 19(5), p. 1054. https://doi.org/10.3390/s19051054
  12. Dang, N.L., Huynh, T.C., Pham, Q.Q., Lee, S.Y. and Kim, J.T. (2020a), "Damage-sensitive impedance sensor placement on multi-strand anchorage based on local stress variation analysis", Struct. Control Health Monitor., 27, p. e2547. https://doi.org/10.1002/stc.2547
  13. Dang, N.L., Pham, Q.Q. and Kim, J.T. (2020b), "Piezoelectric- based hoop-type interface for impedance monitoring of local strand breakage in prestressed multi-strand anchorage", Struct. Control Health Monitor., 28(1), 1-20. https://doi.org/10.1002/stc.2649
  14. Fang, Z. and Wang, J.Q. (2010), "Practical formula for cable tension estimation by vibration method", J. Bridge Eng., 17(1), 161-164. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000200
  15. Giurgiutiu, V. and Rogers, C.A. (1998), "Recent advancements in the electromechanical (E/M) impedance method for structural health monitoring and NDE", In: Smart Structures and Materials 1998: Smart Structures and Integrated Systems, Vol. 3329, pp. 536-547. https://doi.org/10.1117/12.316923
  16. Gudmundson, P. (1982), "Eigenfrequency changes of structures due to cracks, notches or other geometrical changes", J. Mech. Phys. Solids, 30(5), 339-353. https://doi.org/10.1016/0022-5096(82)90004-7
  17. Hiba, A.J. and Glisic, B. (2018), "Monitoring of long-term prestress losses in prestressed concrete structures using fiber optic sensors", Struct. Health Monitor., 18(1), 254-269. https://doi.org/10.1177/1475921717751870
  18. Hiba, A.J. and Glisic, B. (2019), "Monitoring of prestressing forces in prestressed concrete structures-An overview", Struct. Control Health Monitor., 26(8), e2374-1-27. https://doi.org/10.1002/stc.2374
  19. Ho, D.D., Kim, J.T., Stubbs, N. and Park, W.S. (2012), "Prestressforce estimation in PSC girder using modal parameters and system identification", Adv. Struct. Eng., 15(6), 997-1012. https://doi.org/10.1260/1369-4332.15.6.997
  20. Hoang, T., Fu, Y., Mechitov, K., Sanchez, F.G., Kim, J.R., Zhang, D. and Spencer, B.F. (2020), "Autonomous end-to-end wireless monitoring system for railroad bridges", Adv. Bridge Eng., 1(1), 1-27. https://doi.org/10.1186/s43251-020-00014-7
  21. Huynh, T.C. and Kim, J.T. (2014), "Impedance-based cable force monitoring in tendon-anchorage using portable PZT-interface technique", Mathe. Problems Eng., 2014, 1-11. https://doi.org/10.1155/2014/784731
  22. Huynh, T.C. and Kim, J.T. (2017), "Quantitative damage identification in tendon anchorage via PZT interface-based impedance monitoring technique", Smart Struct. Syst., Int. J., 20(2), 181-195. https://doi.org/10.12989/sss.2017.20.2.181
  23. Huynh, T.C., Nguyen, T.D., Ho, D.D., Dang, N.L. and Kim, J.T. (2020), "Sensor fault diagnosis for impedance monitoring using a piezoelectric-based smart interface technique", Sensors, 20(2), p. 510. https://doi.org/10.3390/s20020510
  24. Kim, J.T. and Stubbs, N. (2003b), "Crack detection in beam-type structures using frequency data", J. Sound Vib., 259(1), 145-160. https://doi.org/10.1006/jsvi.2002.5132
  25. Kim, J.T., Ryu, Y.S., Cho, H.M. and Stubbs, N. (2003a), "Damage identification in beam-type structures: frequency-based method vs mode-shape-based method", Eng. Struct., 25(1), 57-67. https://doi.org/10.1016/S0141-0296(02)00118-9
  26. Kim, J.T., Yun, C.B., Ryu, Y.S. and Cho, H.M. (2004), "Identification of prestress-loss in PSC beams using modal information", Struct. Eng. Mech., Int. J., 17(3_4), 467-482. https://doi.org/10.12989/sem.2004.17.3_4.467
  27. Kim, J.T., Park, J.H., Hong, D.S. and Park, W.S. (2010), "Hybrid health monitoring of prestressed concrete girder bridges by sequential vibration-impedance approaches", Eng. Struct., 32(1), 115-128. https://doi.org/10.1016/j.engstruct.2009.08.021
  28. Lacidogna, G., Piana, G. and Carpinteri, A. (2019), "Damage monitoring of three-point bending concrete specimens by acoustic emission and resonant frequency analysis", Eng. Fract. Mech., 210, 203-211. https://doi.org/10.1016/j.engfracmech.2018.06.034
  29. Lacidogna, G., Piana, G., Accornero, F. and Carpinteri, A. (2020), "Multi-technique damage monitoring of concrete beams: acoustic emission, digital image correlation, dynamic identification", Constr. Build. Mater., 242, p. 118114. https://doi.org/10.1016/j.conbuildmat.2020.118114
  30. Lan, C., Zhou, Z. and Ou, J. (2014), "Monitoring of structural prestress loss in RC beams by inner distributed Brillouin and fiber Bragg grating sensors on a single optical fiber", Struct. Control Health Monitor., 21(3), 317-330. https://doi.org/10.1002/stc.1563
  31. Lee, S. and Kalos, N. (2014), "Non-destructive testing methods in the US for bridge inspection and maintenance", KSCE J. Civil Eng., 18(5), 1322-1331. https://doi.org/10.1007/s12205-014-0633-9
  32. Lee, S.Y., Huynh, T.C. and Kim, J.T. (2018), "A practical scheme of vibration monitoring and modal analysis for caisson breakwater", Coastal Eng., 137, 103-119. https://doi.org/10.1016/j.coastaleng.2018.03.008
  33. Liang, C., Sun, F.P. and Rogers, C.A. (1994), "Coupled electromechanical analysis of adaptive material systems-determination of the actuator power consumption and system energy transfer", J. Intell. Mater. Syst. Struct., 5(1), 12-20. https://doi.org/10.1177/1045389X9400500102
  34. Min, J., Yun, C.B. and Hong, J.W. (2016), "An electromechanical impedance-based method for tensile force estimation and damage diagnosis of post-tensioning systems", Smart Struct. Syst., Int. J., 17(1), 107-122. https://doi.org/10.12989/sss.2016.17.1.107
  35. Nawy, E.G. (2010), Prestressed Concrete: A Fundamental Approach, Prentice Hall, Hoboken, NJ, USA.
  36. Nguyen, K.D. and Kim, J.T. (2012), "Smart PZT-interface for wireless impedance-based prestress-loss monitoring in tendonanchorage connection", Smart Struct. Syst., Int. J., 9(6), 489- 504. https://doi.org/10.12989/sss.2012.9.6.489
  37. Nie, J.G., Zhou, M., Wang, Y.H., Fan, J.S. and Tao, M.X. (2014), "Cable anchorage system modeling methods for self-anchored suspension bridges with steel box girders", J. Bridge Eng., 19(2), 172-185. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000529
  38. Park, J.-H. (2009), "Development of autonomous smart sensor nodes for hybrid structural health monitoring of large structures", Ph. D. Dissertation; Pukyong National University, Busan, Korea.
  39. Putcha, C., Dutta, S. and Rodriguez, J. (2020), "Risk priority number for bridge failures", Practice Period. Struct. Des. Constr., 25(2), p. 04020010. https://doi.org/10.1061/(ASCE)SC.1943-5576.0000480
  40. Richmond, M., Smolka, U. and Kolios, A. (2020), "Feasibility for damage identification in offshore wind jacket structures through monitoring of global structural dynamics", Energies, 13(21), p. 5791. https://doi.org/10.3390/en13215791
  41. Tadros, M.K., Omaishi, N.A., Seguirant, S.J. and Gallt, J.G. (2003), "Prestress losses in pretensioned high-strength concrete bridge girders", Report No. NCHRP REPORT 496; National Cooperative Highway Research Program, Transportation Research Board, Washington, D.C., USA.
  42. VSL (2018), VSL Strand Post-tensioning Systems, Available online, accessed 12 June 2018. https://vsl.com/home/technologies/post-tensioning-systems/
  43. Wei, F. and Pizhong, Q. (2010), "Vibration-based damage identification methods: a review and comparative study", Struct. Health Monitor.: Int. J., 10(1), 83-111. https://doi.org/10.1177/1475921710365419
  44. Yang, Y., Hu, Y. and Lu, Y. (2008a), "Sensitivity of PZT impedance sensors for damage detection of concrete structures", Sensors, 8(1), 327-346. https://doi.org/10.3390/s8010327
  45. Yang, Y., Lim, Y.Y. and Soh, C.K. (2008b), "Practical issues related to the application of the electromechanical impedance technique in the structural health monitoring of civil structures: I. Experiment", Smart Mater. Struct., 17(3), 035008-1-14. https://doi.org/10.1088/0964-1726/17/3/035008
  46. Ye, X., Jin, T. and Yun, C. (2019), "A review on deep learningbased structural health monitoring of civil infrastructures", Smart Struct. Syst., Int. J., 24(5), 567-585. https://doi.org/10.12989/sss.2019.24.5.567
  47. Yi, J.-H. and Yun, C.-B. (2004), "Comparative study on modal identification methods using output-only information", Struct. Eng. Mech., Int. J., 17(3_4), 445-466. https://doi.org/10.12989/sem.2004.17.3_4.445
  48. Yu, Y., Liu, Y., Chen, J., Jiang, D., Zhuang, Z. and Wu, X. (2021), "Detection method for bolted connection looseness at small angles of timber structures based on deep learning", Sensors, 21(9), p. 3106. https://doi.org/10.3390/s21093106
  49. Zui, H., Shinke, T. and Namita, Y. (1996), "Practical formulas for estimation of cable tension by vibration method", J. Struct. Eng., 122(6), 651-656. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:6(651)