DOI QR코드

DOI QR Code

Fire resistance tests of LSF walls under combined compression and bending actions

  • 투고 : 2021.10.28
  • 심사 : 2022.05.21
  • 발행 : 2022.05.25

초록

Cold-formed steel wall panels sheathed with gypsum plasterboard have shown superior thermal and structural performance in fire. Recent damage caused by fire events in Australia has increased the need for accurate fire resistance ratings of wall systems used in low- and mid-rise construction. Past fire research has mostly focused on light gauge steel framed (LSF) walls under uniform axial compression and LSF floors under pure bending. However, in reality, LSF wall studs may be subject to both compression and bending actions due to eccentric loading at the wall to-roof or wall-to-floor connections. In order to investigate the fire resistance of LSF walls under the effects of these loading eccentricities, four full-scale standard fire tests were conducted on 3 m × 3 m LSF wall specimens lined with two 16 mm gypsum plasterboards under different combinations of axial compression and lateral load ratios. The findings show that the loading eccentricity can adversely affect the fire resistance level of the LSF wall depending on the magnitude of the eccentricity, the resultant compressive stresses in the hot and cold flanges of the wall studs caused by combined loading and the temperatures of the hot and cold flanges of the studs. Structural fire designers should consider the effects of loading eccentricity in the design of LSF walls to eliminate their potential failures in fire.

키워드

과제정보

The authors wish to thank Australian Research Council (Grant Number LP170100951) and National Association of Steel Framed Housing (NASH) for providing financial support and QUT for providing the required research facilities. They appreciate the valuable technical guidance and support provided by NASH Executive Director Ken Watson, and NASH Standards Committee members to this research study. They also extend their appreciation to the Banyo Laboratory technical staff for their support to the experimental study. Finally, the authors acknowledge the generous contributions of BLUESCOPE® Steel, ENDUROFRAME® and USG BORAL® in providing the required CFS studs and plasterboards.

참고문헌

  1. Ariyanayagam, A.D. and Mahendran, M. (2014), "Numerical modelling of load bearing light gauge steel frame wall systems exposed to realistic design fires", Thin-Walled Struct., 78, 148-170. https://doi.org/10.1016/j.tws.2014.01.003.
  2. Ariyanayagam, A.D. and Mahendran, M. (2018), "Experimental study of non-load bearing light gauge steel framed walls in fire", J. Constr. Steel Res., 145, 529-551. https://doi.org/10.1016/j.jcsr.2018.02.023.
  3. Ariyanayagam, A.D. and Mahendran, M. (2018), "Fire performance of load bearing LSF wall systems made of low strength steel studs", Thin-Walled Struct., 130, 487-504. https://doi.org/10.1016/j.tws.2018.05.018.
  4. Ariyanayagam, A.D. and Mahendran, M. (2019), "Influence of cavity insulation on the fire resistance of light gauge steel framed walls", Constr. and Build. Mater., 203, 687-710. https://doi.org/10.1016/j.conbuildmat.2019.01.076.
  5. Chen, W., Ye, J., Bai, Y. and Zhao, X.L. (2012), "Full-scale fire experiments on load-bearing cold-formed steel walls lined with different panels", J. of Constr. Steel Res., 79, 242-254. https://doi.org/10.1016/j.jcsr.2012.07.031.
  6. Chen, W., Ye, J., Zhao, Q. and Jiang, J. (2020), "Full-scale experiments of gypsum-sheathed cavity-insulated cold-formed steel walls under different fire conditions", J. Constr. Steel Res., 164, 105809. https://doi.org/10.1016/j.jcsr.2019.105809.
  7. Dias, Y., Mahendran, M. and Poologanathan, K. (2019), "Fullscale fire resistance tests of steel and plasterboard sheathed web-stiffened stud walls", Thin-Walled Struct., 137, 81-93. https://doi.org/10.1016/j.tws.2018.12.027.
  8. Feng, M., Wang, Y.C. and Davies, J.M. (2018), "Behaviour of loaded full-scale cold-formed thin-walled steel structural panels under fire conditions", Thin-Walled Struct., CRC Press, 307-314. https://doi.org/10.1201/9781351077309-33.
  9. Gnanachelvam, S., Ariyanayagam, A. and Mahendran, M. (2020), "Fire resistance of LSF wall systems lined with different wallboards including bio-PCM mat", J. Build. Eng., 32, p.101628. https://doi.org/10.1016/j.jobe.2020.101628
  10. Gnanachelvam, S., Ariyanayagam, A. and Mahendran, M. (2021), "Effects of insulation materials and their location on the fire resistance of LSF walls", J. Build. Eng., 44, 103323. https://doi.org/10.1016/j.jobe.2021.103323.
  11. Gunalan, S. and Mahendran, M. (2013), "Finite element modelling of load bearing cold-formed steel wall systems under fire conditions", Eng. Struct., 56, 1007-1027. https://doi.org/10.1016/j.engstruct.2013.06.022.
  12. Jatheeshan, V. and Mahendran, M. (2016), "Experimental study of cold-formed steel floors made of hollow flange channel section joists under fire conditions", J. Struct. Eng., 142, 04015134. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001409.
  13. Kesawan, S. and Mahendran, M. (2018), "A review of parameters influencing the fire performance of light gauge steel frame walls", Fire Technol., 54(1), 3-35. https://doi.org/10.1007/s10694-017-0669-8.
  14. Kodur, V.K.R. and Sultan, M.A. (2006), "Factors influencing fire resistance of load-bearing steel stud walls", Fire Technol., 42(1), 5-26. https://doi.org/10.1007/s10694-005-3730-y.
  15. Kyvelou, P., Gardner, L. and Nethercot, D.A. (2018), "Finite element modelling of composite cold-formed steel flooring systems", Eng. Struct., 158, 28-42. https://doi.org/10.1016/j.engstruct.2017.12.024.
  16. Magarabooshanam, H., Ariyanayagam, A. and Mahendran, M. (2019), "Behaviour of load bearing double stud LSF walls in fire", Fire Safety J., 107, 15-28. https://doi.org/10.1016/j.firesaf.2019.05.003.
  17. Pancheti, J., Mahendran, M. and Steau, E. (2022), "Fire resistance of external LSF walls with corrugated steel cladding", J. Constr. Steel Res., 188, 107008. https://doi.org/10.1016/j.jcsr.2021.107008.
  18. Peiris, M. and Mahendran, M. (2021), "Behaviour of cold-formed steel lipped channel sections subject to eccentric axial compression", J. Constr. Steel Res., 184, 106808. https://doi.org/10.1016/j.jcsr.2021.106808.
  19. Peiris, M., Mahendran, M. (2022), "Advanced numerical modelling of light-gauge steel framed walls subject to eccentric compression", Eng. Struct., 256, 114063. https://doi.org/10.1016/j.engstruct.2022.114063.
  20. Rajanayagam, H., Upasiri, I., Poologanathan, K., Gatheeshgar, P., Sherlock, P., Konthesingha, C., Nagaratnam, B. and Perera, D. (2021), "Thermal performance of LSF wall systems with vacuum insulation panels", Buildings, 11(12), 621. https://doi.org/10.3390/buildings11120621.
  21. Rokilan, M. and Mahendran, M. (2020), "Elevated temperature mechanical properties of cold-rolled steel sheets and coldformed steel sections", J. Constr. Steel Res., 167, 105851. https://doi.org/10.1016/j.jcsr.2019.105851.
  22. Schafer, B.W. (2019), "Advances in the direct strength method of cold-formed steel design", Thin-Walled Struct., 140, 533-541. https://doi.org/10.1016/j.tws.2019.03.001.
  23. Selvaraj, S. and Madhavan, M. (2019), "Improvements in AISI design methods for gypsum-sheathed cold-formed steel wall panels subjected to bending", J. Struct. Eng., 145(2), 04018243. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002223.
  24. Standards Australia (2014), AS 1530.4, Methods for Fire Tests on Building Materials, Components and Structures, Part 4: FireResistance Test of Elements of Construction, Sydney, Australia
  25. Steau, E. and Mahendran, M. (2021), "Elevated temperature thermal properties of fire protective boards and insulation materials for light steel frame systems", J. Build. Eng., 102571. https://doi.org/10.1016/j.jobe.2021.102571.
  26. Thanasoulas, I.D., Vardakoulias, I.K., Kolaitis, D.I., Gantes, C.J. and Founti, M.A. (2018), "Coupled thermo-mechanical simulation for the performance-based fire design of CFS drywall systems", J. Constr. Steel Res., 145, 196-209. https://doi.org/10.1016/j.jcsr.2018.02.022.