DOI QR코드

DOI QR Code

A Clinical Study on the Diagnosis and Observation of Functional Dyspepsia - Focused on Algometer

  • Gi-Hwan Rho (Department of Internal Medicine, Weedahm Korean Medical Hospital) ;
  • Gyu-Ho Choi (Department of Internal Medicine, Weedahm Korean Medical Hospital) ;
  • Sang-Hyun Lee (Department of Internal Medicine, Weedahm Korean Medical Hospital) ;
  • Hyeon-Min Noh (Department of Internal Medicine, Weedahm Korean Medical Hospital) ;
  • Seo-Hyung Choi (Department of Internal Medicine, Gangnam Weedahm Korean Medical Hospital)
  • Received : 2022.05.25
  • Accepted : 2022.09.14
  • Published : 2022.12.01

Abstract

Objectives: This study aimed to determine whether comparing the pressure pain threshold (PPT) with an algometer before and after treatment for functional dyspepsia is of diagnostic value and investigate a possible correlation between PPT measured using an algometer and symptom improvement before and after treatment. Methods: A total of 99 patients with functional dyspepsia symptoms admitted to the OO Korean Medical Hospital from April 14, 2020 to January 21, 2021 were investigated. On the 1st and 14th days of hospitalization, the pressure of the first pain complaint at acupuncture points Juque (巨厥, CV14), Shangwan (上脘, CV13), Zhongwan (中脘, CV12), Xiawan (下脘, CV10), Guanuan (關元, CV4), Tianshu (天樞, ST25), and Daju (大巨, ST27) was measured using the algometer, and the visual analog scale (VAS) scores for patient's symptoms were evaluated. The algometer PPT and patient-symptom VAS scores were compared by repeated measures corresponding to the sample t-test to analyze the changes after treatment. A correlation analysis was performed to identify the correlation between patient-symptom VAS scores and algometer PPT. Results: The PPT measured using the algometer significantly increased after treatment in the 99 patients. The patient-symptom VAS score decreased significantly in most cases as treatment progressed. Analysis of the correlation between algometer PPT and patient-symptom VAS scores revealed some notable negative correlations. Conclusion: The algometer can help to set the diagnostic and treatment baselines for patients with functional dyspepsia.

Keywords

References

  1. Tack, J., Talley, N, J., Camilleri, M., Holtmann, G., Hu, P., Malagelada, JR., et al. (2006). Functional gastroduodenal disorders. Gastroenterology. 130(5),1466-1479. https://doi.org/10.1053/j.gastro.2005.11.059. 
  2. Park, Y,J., Park, J,S., Kim, M,Y., Park, Y,B. (2011). Development of a valid and reliable phlegm pattern questionnaire. J Altern Complement Med. 17(9),851-858. https://doi.org/10.1089/acm.2010.0504. 
  3. Ko, SJ., Kim, H., Kim, SK., Park, K., Lee, J., Lee, BJ., et al. (2016). Reliability and validity of modified algometer in abdominal examination. Evid Based Complement Alternat Med. 2016,3052954. https://doi.org/10.1155/2016/3052954. 
  4. Ko, SJ., Lee, H., Kim, SK., Kim, M., Kim, J., Lee, BJ., et al. Development of the quantitative indicator of abdominal examination for clinical application: a pilot study. (2015). J Altern Complement Med. 21(6),358-363. https:// doi.org/10.1089/acm.2014.0185.