DOI QR코드

DOI QR Code

압축기 갭 유로 형상에 따른 압축기 EER 향상

Improvement of Compressor EER Based on Shape of Gap Flow Passage

  • 한상혁 (공주대학교 대학원 기계공학과) ;
  • 이영림 (공주대학교 기계자동차공학부)
  • Han, Sang-Hyeok (School of Mech. Eng., Graduate School, Kongju National UNIV.) ;
  • Lee, Young Lim (Dept. of Mech. and Auto. Eng., Kongju National UNIV.)
  • 투고 : 2021.11.05
  • 심사 : 2022.01.14
  • 발행 : 2022.03.31

초록

Compressor efficiency must be improved to reduce refrigerator power consumption. In this study, the heat dissipation rate through the compressor housing is increased via gap flow passages between the compressor body and housing. Four types of gap flow passages are considered for achieving the maximum heat-dissipation rate. In addition, thermal analysis is performed to examine the effect of increased heat dissipation rate on the energy efficiency ratio (EER). The results show that the heat dissipation rate, compressor superheat, and compressor EER increased by up to approximately 52%, 3 ℃, and approximately 1%, respectively.

키워드

과제정보

이 논문은 2016년도 정부(교육부)의 재원으로 한국연구재단의 지원을 받아 수행된 기초연구사업(No. NRF-2016R1D1A1B02009582)의 연구과제임. 또한 지자체-대학 협력기반 지역혁신 사업(2021RIS-004)의 일부 지원으로 수행되었음.

참고문헌

  1. Porkhial, S., Khastoo, B. and Modarres Razavi, M. R., "Transient characteristic of reciprocating compressor in household refrigerators", Applied thermal engineering, Vol. 26, No. 14, pp. 1725-1729, 2002. https://doi.org/10.1016/j.applthermaleng.2005.11.005
  2. Lee, H. K., and Jung, W. H., "Development of the linear compressor for a household refrigerator", Proceedings international compressor engineering conference, Purdue University, 2000.
  3. Hou, X., Gu, Z., Gao, X., Feng, S. and Li, Y., "Analysis of efficiency and power factor of reciprocating compressor unit under variable-frequency and variable-conditions", Proceedings international compressor engineering conference, Purdue University, 2008.
  4. Oh, H. J., Kong, S. C., Oh, W. S. and Park, K. B., "Numerical simulation for the internal flow analysis of the linear compressor with improved muffler", Proceedings international compressor engineering conference, Purdue University, 2016.
  5. Binnberg, P., Kraus, E. and Quack, H., "Reduction in power comsumption of household refrigerators by using variable speed compressor", International refrigeration and air conditioning conference, 2002.
  6. Hwang, I. S. and Lee, Y. L., "A study on the cooling of high temperature refrigerant inside a compressor using compressor body vibration", Journal of Korean Society of Mechanical Technology, Vol. 23, No. 1, pp. 50-55, 2021. https://doi.org/10.17958/KSMT.23.1.202102.50
  7. Jang, Y. N. and Lee, Y. L., "Effects of a cooling fan in the machine room on the performance of a compressor", Journal of Korean Society of Mechanical Technology, Vol. 20, No. 1, pp. 48-54, 2018. https://doi.org/10.17958/ksmt.20.1.201802.48
  8. Jeon, W. J., Son, S. I., Lee, H., Kim, J. W. and Kim, K. W., "Influence of groove location on lubrication characteristics of the piston and cylinder in a linear compressor", Journal of Korean Society of Tribology and Lubrication engineers, Vol. 32, No. 1, pp. 24-31, 2016. https://doi.org/10.9725/kstle.2016.32.1.24
  9. Hwang, I. S. and Lee, Y. L., "Improvement of compressor-cooling efficiency based on ribs", Journal of the Korean Society of Manufacturing Process Engineers, Vol. 20, No. 6, pp. 70-75, 2021. https://doi.org/10.14775/ksmpe.2021.20.06.070
  10. Ansys Fluent version 15, Ansys Inc.
  11. Hwang, I. S. and Lee, Y. L., "CFD analysis of transient flows in a linear compressor using a 1D-CFD coupled model", International journal of Refrigeration, Vol. 91, pp. 20-27, 2018. https://doi.org/10.1016/j.ijrefrig.2018.04.015
  12. Oliverira, M. J., "Modeling thermal compressor reciprocal linear operating without oil lube", Federal de Santa Catarina university, pp. 101-111, 2014.