Analysis of Fine Dust Removal Performance According to Types of Ventilation System in a Multifamily Residential Building

공동주택 기계환기설비의 급·배기 유형에 따른 미세먼지 제거성능 분석

  • An, Jung Seok (Dept. of Architectural Engineering, University of Seoul) ;
  • Eom, Ye Seul (Dept of Architectural Engineering, University of Seoul) ;
  • Kang, Dong Hwa (Dept of Architectural Engineering, University of Seoul)
  • 안중석 (서울시립대학교 대학원 건축공학과) ;
  • 엄예슬 (서울시립대학교 건축학부 건축공학전공) ;
  • 강동화 (서울시립대학교 건축학부 건축공학전공)
  • Received : 2022.07.06
  • Accepted : 2022.10.30
  • Published : 2022.12.30

Abstract

This study aims to conduct a comparative analysis of fine dust removal performance according to the design methods of ventilation systems in a multifamily residential housing unit. To evaluate the performance of a ventilation system, Simulation House Model (SHM) was constructed in a CONTAM environment to simulate the airflow in a duct system and assess the interzonal particle transport characteristics in an actual residential housing unit. The key parameters like leakage areas of building components and particle transport parameters of SHM were obtained from field measurements. The key parameters of SHM including leakage areas of building components and particle transport parameters were obtained from field measurements. The results from the validation and SHM simulation provided a good prediction for the indoor concentration of particle with a diameter of 0.3 ㎛ that showed a correlation coefficient higher than 0.8. The simulation results revealed that the clean air delivery rate (CADR) of an unbalanced ventilation system was reduced by up to 13% compared to a balanced ventilation, especially when the interzonal particle transport was restricted with closed doors.

Keywords

References

  1. ASHRAE (2009). 2009 ASHRAE Handbook Fundamentals. American Society of Heating Refrigeration and Air-Conditioning Engineers, Atlanta, GA.
  2. ASTM (2019). E779-19 Test Method for Determining Air Leakage Rate by Fan Pressurization. ASTM International, West Conshohocken.
  3. Baik, Y., & Jung, Y. (2009). Performance evaluation of multidrop chamber ventilation system in apartment. Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, 3(4), 163-168.
  4. Chao, C., Wan, M., & Cheng, E. (2003). Penetration coefficient and deposition rate as a function of particle size in non-smoking naturally ventilated residences. Atmospheric Environment, 37, 4233-4241. https://doi.org/10.1016/S1352-2310(03)00560-0
  5. Chen, C., Zhao, B., Zhou, W., Jiang, X., & Tan, Z. (2012). A methodology for predicting particle penetration factor through cracks of windows and doors for actual engineering application. Building and Evironment, 47, 339-348.
  6. Cho, H., Choi, I., & Bang, S. (2011). Prediction of energy consumption and indoor ventilation performance according to individual room control ventilation system in apartment house. Journal of The Korean Society of Living Environmental System, 18(4), 411-418
  7. Cho, K., Cho, D., & Kim, T. (2020). Experimental study on the fan power changes and ultra-fine dust removals depending on different filters of heat recovery ventilation systems - focused on the circulation mode of heat recovery ventilation system. Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, 20(4), 77-82.
  8. Cho, Y., & Sung, M. (2021). Experimental verification for particle removal efficiency of heat recovery ventilation systems with air filter. Architectural Institute of Korea, 37(10), 149-157.
  9. Ferro, A. R., Klepeis, N. E., Ott, W. R., Nazaroff, W. W., Hildemann, L. M., & Switzer, P. (2009). Effect of interior door position on room-to-room differences in residential pollutant concentrations after short-term releases. Atmospheric Environment, 43(3), 706-714. https://doi.org/10.1016/j.atmosenv.2008.09.032
  10. Hong, S., & Yoon, D. (2011). A CO2 Sensor based demand controlled ventilation strategies with multi-zone analysis in the apartment house. Journal of the Architectural Institute of Korea Planning & Design, 27(9), 341-348.
  11. Hong, S., Yoon, D., & Kim, S. (2010). The performance on the individual control of room ventilation using multidrop chamber operated by motor dampers in residential house. Journal of The Korean Society of Living Environmental System, 17(5), 634-641.
  12. Kim. C., Park. J., Kim. D., Shin. B., Kum. J.(2015). A study of the indoor thermal environment in apartment buildings in freezing weather operation of heat recovery ventilator by CFD simulation. Korean Journal of Air-Conditioning and Refrigeration Engineering, 27(6), 293-299. https://doi.org/10.6110/KJACR.2015.27.6.293
  13. Kim, M., Park, J., & Lee, J. (2019). Development of "pre-filter system" for improving particulate matter filtering performance of multi-unit heat recovery ventilation system. Journal of The Korean Society of Living Environmental System, 26(5), 641-648. https://doi.org/10.21086/ksles.2019.10.26.5.641
  14. Kim, S., & Son, J. (2009). Performance evaluation of multidrop chamber ventilation system in apartment. Korean Journal of Air-Conditioning and Refrigeration Engineering, 9(4), 17-22.
  15. Kim, S., Yee, J., & Lee, S. (2007). Measurement and prediction on indoor air quality according to operating conditions of heat recovery ventilator combined air cleaning function in an apartment. Journal of the Architectural Institute of Korea Planning & Design, 23(1), 247-254
  16. McGrath, J. A., Byrne, M. A., Ashmore, M. R., Terry, A. C., & Dimitroulopoulou, C. (2014). A simulation study of the changes in PM2.5 concentrations due to interzonal airflow variations caused by internal door opening patterns. Atmospheric Environment, 87, 183-188. https://doi.org/10.1016/j.atmosenv.2014.01.050
  17. Park, B., Choi, D., & Kang, D. (2020). Seasonal contribution of indoor generated and outdoor originating PM2.5 to indoor concentration depending on airtightness of apartment units. Journal of the Architectural Institute of Korea Structure & Construction, 36(2), 155-163.
  18. Park, H., Park, S., & Seo, J. (2019). Study on the indoor PM concentration changes by SA·RA location of air cleaning ventilation system in residential space. Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, 13(2), 105-115.
  19. Song, Y. (2020). Evaluation of particulate matter removal rate according to filter type and thickness of total heat exchanger in apartment houses. LHI Journal of Land, Housing, and Urban Affairs, 11(4), 93-98. https://doi.org/10.5804/LHIJ.2020.11.4.93
  20. Won, M. (2015). A Study on the Particle Size Distribution of PM 2.5 by Means of QCM(Quartz Crystal Microbalance). Thesis, University of Seoul, 37-39.