DOI QR코드

DOI QR Code

CATHARE simulation results of the natural circulation characterisation test of the PKL test facility

  • Received : 2020.05.30
  • Accepted : 2020.11.15
  • Published : 2021.05.25

Abstract

In the past, several experimental investigations aiming at characterizing the natural circulation (NC) behavior in test facilities were carried out. They showed a variety of flow patterns characterized by an inverted U-shape of the NC flow curve versus primary mass inventory. On the other hand, attempts to reproduce such curves using thermal-hydraulic system codes, showed 10-30% differences between the measured and calculated NC mass flow rate. Actually, the used computer codes are generally based upon nodalization using single U-tube representation. Such model may not allow getting accurate simulation of most of the NC phenomena occurring during such tests (like flow redistribution and flow reversal in some SG U-tubes). Simulations based on multi-U-tubes model, showed better agreement with the overall behavior, but remain unable to predict NC phenomena taking place in the steam generator (SG) during the experiment. In the current study, the CATHARE code is considered in order to assess a NC characterization test performed in the four loops PKL facility. For this purpose, four different SG nodalizations including, single and multi-U-tubes, 1D and 3D SG inlet/outlet zones are considered. In general, it is shown that the 1D and 3D models exhibit similar prediction results up to a certain point of the rising part of the inverted U-shape of the NC flow curve. After that, the results bifurcate with, on the one hand, a tendency of the 1D models to over-predict the measured NC mass flow rate and on the other hand, a tendency of the 3D models to under-predict the NC flow rate.

Keywords

Acknowledgement

This paper contains findings that were produced within the NEA/OECD-PKL-4 Project. The author is grateful to the PKL operating agent and to the Management Board of the Project for their consent for this publication. Special thanks to M. Adorni for her careful review of the paper.

References

  1. R.R. Schultz, J.C. Chapman, Y. Kukita, F.E. Motley, H. Stumpf, Y.S. Chen, L. Tasaka, Single and two-phase natural circulation in westinghouse PWR simulators: phenomena, analysis and scaling, in: ASME International Symposium on Natural Circulation, Boston, USA, 17 Dec 1987.
  2. P.R. McHugh, R.D. Hentzen, 'Natural Circulation Cooling in US PWRs', NUREG/CR-5769, 1991.
  3. Y. Kukita, H. Nakamura, K. Tasaka, Nonuniform steam generator U-tube flow distribution during natural circulation tests in ROSA-IV large scale test facility, Nucl. Sci. Eng. 99 (1988) 289-298. https://doi.org/10.13182/NSE99-289
  4. C. Chauliac, Y. Kukita, M. Kawaji, H. Nakamura, K. Tasaka, Post-test Analysis with RELAP5/Mod2 of ROSA-IV/LSTF Natural Circulation Test ST-NC-02, October 1988. JAERI-M-88-215.
  5. Equipe CATHARE, DRN/DTP/SMTH/LMDS, "CATHARE-2 V2.5_1/mod8.1 Dictionary", 2008. SMTH/LMDS/EM/2002_067.
  6. S.P. Schollenberger, K. Umminger, PKL IIIi NC-Flowmap Test, 2017.
  7. A. Bousbia Salah, J. Vlassenbroeck, H. Austregesilo, Experimental and analytical assessment of natural circulation interruption phenomenon in the LSTF and PKL test facilities, ANS Nucl. Tech. 192 (2015) 1-10. https://doi.org/10.13182/NT14-51
  8. S.P. Schollenberger, K. Umminger, Determination of Pressure Losses in the PKL III Test Facility for Mass Flows of 0.8 to 25.0 Kg/s Per Loop, 2006. NTT1-G/2006/en/0066.
  9. C.F. Boyd, D.M. Helton, K. Hardesty, CFD Analysis of Full-Scale Steam Generator Inlet Plenum Mixing during a PWR Severe Accident, 2004. NUREG-1788.

Cited by

  1. Review and outlook of the integral test facility PKL III corresponding studies vol.86, pp.6, 2021, https://doi.org/10.1515/kern-2021-1011