DOI QR코드

DOI QR Code

작업환경측정시료의 분석수탁기관과 자율정도관리 참여와의 연관성

Relationship of the Institutes for Analyzing Requested Samples(IARS) among Working Environment Measuring Institutes(WMIs) and the Participation of the Non-mandatory Proficiency Test

  • 김성호 (안전보건공단 산업안전보건연구원 직업환경연구실) ;
  • 권지운 (안전보건공단 산업안전보건연구원 직업환경연구실) ;
  • 조현민 (안전보건공단 산업안전보건연구원 직업환경연구실) ;
  • 박해동 (안전보건공단 산업안전보건연구원 직업환경연구실)
  • Kim, Sungho (Occupational Safety and Health Research Institute, Korea Occupational Safety and Health Agency) ;
  • Kwon, Jiwoon (Occupational Safety and Health Research Institute, Korea Occupational Safety and Health Agency) ;
  • Cho, Hyunmin (Occupational Safety and Health Research Institute, Korea Occupational Safety and Health Agency) ;
  • Park, Hae Dong (Occupational Safety and Health Research Institute, Korea Occupational Safety and Health Agency)
  • 투고 : 2021.03.18
  • 심사 : 2021.06.10
  • 발행 : 2021.06.30

초록

Objectives: The necessity of samples for analysis requested by working environment monitoring institutes (WMIs) has grown recently. The collection of samples of a few chemical substances requested by WMIs is allowed under the current occupational safety and health act in Korea, leading to an expansion of samples for analysis requested by institutes (SRIs). The objective of this study was to identify the number of institutes for analyzing requested samples (IARS), SRIs, and their participation in a non-mandatory proficiency test. Methods: Questionnaires were completed by all WMIs. The collected information was quantity of analysis equipment, sorting of chemicals from SRIs, and the number of SRIs. This was compared in terms of the participation in the non-mandatory proficiency test. Results: All WMIs in Korea responded to the survey, establishing a 100% response rate. There were 52 (29%) IARS among the 179 WMIs in Korea. The total number of samples of acid for ion chromatograph (IC) analysis requested by WMIs was 21,165, which is the most. Even the number of IARS for crystalline silicon oxide was less than other top-five IARS. The total amount of samples was 13,863, which was the second most. The calculated participation score for IARS was significantly higher than other WMIs (p<0.001). According to participation in the non-mandatory proficiency test by type of substance, such as crystalline silicon oxide and formaldehyde among IARS, the number of SRIs from those IARS was significantly higher than IARS that did not participate in the proficiency test (p<0.05). Conclusions: IARS had a high frequency of participation in the non-mandatory proficiency test and the number of SRIs at IARS participating in the proficiency test was higher among IARS. With the revision of the occupational health and safety act in Korea, the number of IARS participating in the non-mandatory proficiency test might increase.

키워드

참고문헌

  1. Choi SJ. Assessment on work environment monitoring program in Korea. J Korean Soc of Occup Environ Hyg. 2008;18(4): 282-292
  2. Korean Industrial Health Association(KIHA). History of the establishment and revision of the occupational safety and health act; Korea occupational health association.; 2019;374. p. 44-47
  3. Ha KC. Yoon CS, Kim SW, et al. A study on the improvement of specification requirements and efficiency of evaluation system of legally designated agency for employee's exposure assessment. Occupational safety and health research institute. 2017
  4. Jang JK. Evaluation of the possession of measurement and analytical instruments in domestic work environment monitoring service providers(II). J Korean Soc of Occup Environ Hyg. 2014;24(2): 182-192(http://dx.doi.org/10.15269/JKSOEH.2014.24.2.182)
  5. Kang SG. Special article: background and contents of the work environment measurement system innovation proposal. Safety world(www.safetygo.com). 2012
  6. Kim CY. Current status, problems and improvement measures of the work environment measurement system in Korea. Korea occupational health association. 2005;207. p. 53-55
  7. Kwon JW, Jang KH, Hwang ES, Kim KW. A study on the reliability of respirable crystalline silica measurements. Occupational safety and health research institute. 2017
  8. Lautenberg FR. Toxic substances control act(TSCA). EPA. 2020 Sep
  9. Lee BG. History of occupational diseases in Korea. Korea occupational health association. 1989;10. p. 6-12
  10. Ministry of Empolyment and Labor(MoEL). Notification on work environment measurement and proficient test, etc. Ministry of Employment and Labor(MoEL).; 2020. p. 21-31
  11. Park HD, Chung EK, Kim KW. The quality control program for industrial hygiene laboratories in Korea. Saf Health Work. 2017. p. 1-5(http://dx.doi.org/10.1016/j.shaw.2017.08.003)
  12. Park HD, Jang MY, Park SH. A study to introduce an autonomous item for the quality control program in the industrial hygiene (1) - Formaldehyde. Occupational safety and health research institute. 2018
  13. Park HD, Park SH. A study on the autonomous ites of quality control for management of analysis entrusted organizations according to the revision of the OSH Act - Inorganic acids. Occupational safety and health research institute. 2020
  14. Song YK, Yoon HC, Ryu JS, Lee JH. Press release for chemical substance distribution survey in 2016. Ministry of Environment. 2018 Oct