DOI QR코드

DOI QR Code

A Study on the Reduction Plan of Dust Dispersion at Small-Scale Construction Sites in Downtown Seoul

서울 도심지 내 소규모 공사현장 비산먼지 감소방안에 관한 연구

  • 조정규 (충북대학교 토목공학과) ;
  • 박형근 (충북대학교 토목공학과)
  • Received : 2021.02.08
  • Accepted : 2021.04.07
  • Published : 2021.12.01

Abstract

As public concern for fine dust has increased, so too has the interest in fugitive dust. Fugitive dust generated at construction sites, which is then scattered by vehicles moving around the sites, accounts for a significant portion. Small construction sites, which comprise the majority of construction sites, are often not adequately managed, because there are no regulations on fugitive dust for such sites. Therefore, in this study, in order to contribute to the establishment of fugitive dust management regulations on small-scale construction sites and to prepare measures to reduce fugitive dust, we measured and analyzed fugitive dust generated at small-scale building sites in Seoul. The fluctuations of fugitive dust generated at small-scale sites over time were checked, and the relatively low concentration when measured behind fences and railings suggested that fence installation is an appropriate method of reducing fugitive dust.

최근 미세먼지에 대한 국민들의 불안감이 증가함에 비산먼지에 대한 관심이 증가하고 있다. 비산먼지는 도로재비산먼지 다음으로 건설현장에서 많이 발생하는데 이 중 대부분을 차지하는 소규모 현장은 비산먼지 관련 규정이 없어 제대로 된 관리가 이뤄지지 않고 있는 실정이다. 이에 본 연구에서는 소규모 현장 비산먼지 관리 규정 수립에 기여하고 비산먼지 저감방안을 마련하고자 서울시 소규모 현장에서 발생하는 비산먼지를 측정 및 분석을 진행했다. 소규모 현장에서 발생하는 비산먼지의 시간별 변동을 확인했고 담장과 난간 뒤에서 측정했을 때 상대적으로 농도가 낮은 것을 통해 비산먼지 저감방안으로 간이 펜스 설치 방안을 제시했다.

Keywords

Acknowledgement

본 연구는 환경부 서울녹색환경지원센터의 2020년도 연구과제 지원으로 수행되었으며, 이에 관계자분들에게 감사드립니다.

References

  1. Cha, J. W. and Kim, J. Y. (2018). "Analysis of fine dust correlation between air quality and meteorological factors using SPSS." Journal of the Korea Institute of Information and Communication Engineering, The Korea Institute of Information and Communication Engineering, Vol. 22, No. 5, pp. 722-727 (in Korean). https://doi.org/10.6109/JKIICE.2018.22.4.722
  2. Choi, J. W., Lee, Y. S. and Kim, J. J. (2010). "Effec ts of meteorological and reclaiming conditions on the reduction of suspended particles." Journal of Environmental Sciences, The Korea Environmental Sciences Society, Vol. 19, No. 11, pp. 1423-1436 (in Korean). https://doi.org/10.5322/JES.2010.19.11.1423
  3. Im, S. Y. and Yu, J. H. (2018). "Analysis of fugitive dust measurement technique for fugitive dust management in construction site." Proceeding of Annual Conference of the Architectural Institute of Korea, Architectural Institute of Korea, Vol. 38, No. 1, pp. 672-673 (in Korean).
  4. Kim, D. J., Wang, J. W., Park, S. J. and Kim, J. J. (2018). "A study on the effects of wind fence on the dispersion of the particles emitted from the construction site using GIS and a CFD model." Korean Journal of Remote Sensing, The Korean Society of Remote Sensing, Vol. 34, No. 5, pp. 763-775 (in Korean). https://doi.org/10.7780/KJRS.2018.34.5.5
  5. Kim, J. H. and Kang, S. W. (2018). "Analysis of factors influencing PM10 pollution in Korea." Proceeding of Annual Conference The Korea Resource Economics Association, The Korea Resource Economics Association, Vol. 2018, pp. 779-791 (in Korean).
  6. Ministry of Environmrnt (MOE) (2017). Fugutive dust management manual (in Korean).
  7. Noh, H. J. and Yu, J. H. (2017). "Improvement plan of fugitive dust regulations in construction site." Korean Journal of Construction Engineering and Management, Korea Institute of Construction Engineering Management, Vol. 18, No. 5, pp. 68-76 (in Korean). https://doi.org/10.6106/KJCEM.2017.18.5.068
  8. Park, C. S. (2017). "Variations of PM10 concentration in Seoul during 2015 and relationships to weather condition." Journal of the Association of Korean Photo-Geographers, The Association of Korean Photo-Geographers, Vol. 27, No. 2, pp. 47-64 (in Korean). https://doi.org/10.35149/jakpg.2017.27.2.004
  9. Yang, J. H., Tae, S. H. and Lee, K. S. (2019). "Basic study on the measurement of finedust based on light scattering method in construction site." Proceeding of Annual Conference of the Architectural Institute of Korea, Architectural Institute of Korea, Vol. 39, No. 2, pp. 476-479 (in Korean).
  10. Yoon, B. G., Seo, J. B., Kim, Y. S., Choi, W. J., Kim, Y. S. and Oh, K. J. (2009). "A study of the amount of fugitive dust generated from new harbor construction site and the prediction of effect using AERMOD" Journal of Environmental Health Sciences, The Korea Society of Environmental Health, Vol. 35, No. 4, pp. 304-314. https://doi.org/10.5668/JEHS.2009.35.4.304
  11. Yu, J. H., Han, K. Y., Kwang, S. K., Kim, S. K. and Yang, K. Y. (2004). "A study on the actual condition and effect of dust scattering in construction field." Journal of the Korea Institute of Building Construction, KIBC, Vol. 4, No. 4, pp. 109-115 (in Korean). https://doi.org/10.5345/JKIC.2004.4.4.109