Abstract

In Korea, interest in the seismic design of non-structural elements was stimulated by the 2016 Gyeong-ju 2017 Po-hang earthquake. Among them, the suspended ceiling is a non-structural element that causes injury to person, most ceiling systems used in Korea do not have seismic details and do not meet the current seismic design standards. There is no standard for seismic design of the suspended ceiling in Korea, and the ASTM E580/E580M can be used for the seismic design. The ASTM E580/E580M introduces a seismic design method for SDC C, which performs design with molding width and end clearance, and SDC D, which performs design with braces and end fixing method, in ceiling systems for acoustical tile and lay-in Panels. In the present study, shaking table tests were performed on two types of steel-panel T-bar ceiling systems designed according to ASTM E580/E580M. The first specimen meets the frame end molding width requirements of SDC C detail, the second one meets the perimeter clip requirement of SDC D detail in ASCE7. The failure modes of steel-panel T-bar ceiling system with anti-falling clips, and the degrees of damage incurred by the ceiling system were evaluated. The failure modes were also compared with the results of non-seismic ceiling tests presented in the previous study, which details currently being constructed in Korea. Test results of seismic designed ceilings show that all the specimens meet the life safety level in Korea standard KDS 41 17 00.

Keywords

Acknowledgement

이 연구는 2020년도 국토교통부 도시건축 연구개발사업의 지원에 의한 결과의 일부임. 과제번호: 20AUDP-C146352-03

References

  1. KDS (2019). Seismic Design Code of Buildings (KDS 41 17 00: 2019), Korean Design Standard
  2. American Society of Civil Engineers (ASCE) (2016). ASCE/SEI 7-16: Minimum Design Loads for Buildings and Other Structures, ASCE, Reston, VA, US.
  3. ASTM E580/E580M. (2017). "Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions." ASTM International.
  4. KS D 3609 (2015). Steel furrings for wall and ceiling in buildings
  5. Lee, J., In, S., Jung, D., Lee, D., Lee, S., & Cho, B. (2019). Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test, Journal of the Architectural Institute of Korea Structure & Construction, 35(10)
  6. Lee, J., In, S., Jung, D., Lee, S., & Cho, B. (2019). Shaking-Table Evaluation of Seismic Performance of Suspended Steel-Panel Ceiling, 4th International Workshop on the Seismic Performance of Non-Structural Elements
  7. ICC Evaluation Service, LLC (ICC-ES) (2010). ICC-ES AC156, Acceptance criteria for seismic certification by shake-table testing of non-structural components and systems, International Code Council, Whittier, CA.
  8. Gilani A. S. J., Takhirov S. M., & Tedesco L. M. (2014). Proposed New approach for the seismic evaluation testing of suspended ceiling systems, 10th U.S. National Conference on Earthquake Engineering, 10NCEE, Anchorage, Alaska
  9. Recommendation for A seismic Design and Construction of Nonstructural Elements (2013). Architectural Institute of Japan, Japan