DOI QR코드

DOI QR Code

A Study on Development of PHC pile driving force increase device on soft ground

연약지반상 PHC파일 항타력 증대장치 개발에 관한연구

  • Received : 2020.07.16
  • Accepted : 2020.10.20
  • Published : 2020.10.28

Abstract

The purpose of this study is to develop a device to replace the pre-boring method, which is generally constructed, to prevent pile damage caused by tension cracks that reason from tension waves generated during PHC pile construction on soft ground. Tension cracks are caused by tension waves from the hammer striking during the PHC pile hitting on the soft ground, which in turn leads to faulty construction. In order to prevent the occurrence of tension waves generated during driving, apply separate driving force increasing device to prevent the generation of tension waves, and pile damage as well. Also, it is an eco-friendly construction method that reduces smoke and noise by improving construction speed, reducing construction costs, and able to small equipment when developing equipment. This development equipment is a piece of effective equipment that can pioneer the Saemangeum reclamation area, the South-east Asian construction market, where the Deep soft ground is distributed.

본 연구는 연약지반상에 PHC 파일 시공시 발생하는 인장파에 의해 발생하는 인장 균열에 의한 파일 파손 방지를 위하여 일반적으로 시공되는 선굴착 공법을 대체할 장비 개발에 목적이 있다. 연약지반상에 PHC 파일 항타 중 해머타격시 발생하는 인장파에 의해 인장 균열이 발생하며, 이는 결국 부실시공으로 이어진다. 항타시 발생하는 인장파 발생을 방지하기 위하여 연약층에서는 별도의 항타력 증대 장치를 이용하여 인장파 발생을 방지하여 파일 손상을 방지할 수 있다. 또한 장비 개발시 시공 속도 향상, 시공비 절감 및 소형장비를 사용할 수 있어 매연 및 소음을 감소시키는 친환경 공법이다. 본 개발 장비는 대심도 연약지반이 분포하는 새만금 간척지, 동남아시아 건설시장을 개척할 수 있는 효과적인 장비이다.

Keywords

References

  1. N. H. Kim. (2014). Analysis of drivability and constructability for Spun Pile into special ground conditions. Youshin Technology Newsletter, 80-89.
  2. G. S. Woo, (2016). Evaluation of Allowable Bearing Capacity of 600mm Diameter Preboring PHC Piles Using Dynamic Load Test. Journal of The Korea Geotechnical Society Vol32,No11, 61-72 https://doi.org/10.7843/kgs.2016.32.11.61
  3. K. J. Cho. (2010). Evaluation of the tip resistance of prebored PHC pile on weathered rock. KSCE 2010. 990-993
  4. D. G. Kim. (2017). High strength and ultra high strength PHC pile test case with high design load. KSCE 2017. 55-56
  5. E. A. Hwang. (2017). Suggestion of New Pre-drilling Method for Soft Soils using Multiple Auger Boring Machine Equipped with Wire Ropes. KSCE Vol65No09. 41-45
  6. S. S. Jeong. (2015) Analysis of Load Sharing Ratio for PHC Piled-raft Foundation. KSCE 81-82
  7. H. K. Choi. (2015). A study on the Installation of the Point Foundation as the Substitution method of the soft ground. KSCE 45-46
  8. C. H. Cho. (2004). PHC PILE cracking related technology cases in soft ground. Samsung E&C Technical Information, 15-17.
  9. J. Y. Ko. (2015). Proposed Bearing Capacity for Open-Ended Piles with Soil Plugging. KSCE 47-48
  10. W. P. Hong. (1987). Deep foundation of soft ground. KSCE Vol35.No6. 11-14
  11. K. W. Lee. (1996). Problems and countermeasures in design and construction of ready-made concrete pile foundation. Construction technology Ssangyong.
  12. W. J Lee. (2015). The proposal to Design PHC Piles Properly when used for Civil Engineering Structures. KSCE 163(11), 52-60
  13. J. M. Goo. (2008) Micropiling: Case History and the Improvement of Design Method. KSCE 865-868
  14. Y. H. Lee, (2007). Example of construction method for applying PHC file in soft ground. Geotechnical Engineering 23(7), 9-21
  15. B. K. Kim. (2016) Preliminary study on the Underwater Noise Mitigation Device under Offshore Pile Driving. KSCE. 78-79