Abstract

Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.

Keywords

References

  1. Akamatsu, K., Lu, W., Sugawara, T. and Nakao, S.H. (2010). Development of a novel fouling suppression system in membrane bioreactors using an intermittent electric field, Water Res., 44, 825-830. https://doi.org/10.1016/j.watres.2009.10.026
  2. Chang, I.S., Lee, J.H. and Cho, C.H. (2017). Water treatment system using high voltage impulse, Korean Patent, 10-1731856.
  3. Chen, J.P., Yang, C.Z., Zhou, J.H. and Wang, X.Y. (2007). Study of the influence of the electric field on membrane flux of a new type of membrane bioreactor, J. Chem. Eng., 128, 177-180. https://doi.org/10.1016/j.cej.2006.10.010
  4. Cho, S.Y. and Chang, I.S. (2017). Effect of operating conditions of high voltage impulse on generation of hydroxyl radical, J. Korean Soc. Water Wastewater, 31(6), 611-618. https://doi.org/10.11001/jksww.2017.31.6.611
  5. Han, S.H. and Chang, I.S. (2014). Comparison of the cake layer removal options during determination of cake layer resistance (Rc) in the resistance-in-series model, Sep. Sci. Technol., 49(16), 2459-2465. https://doi.org/10.1080/01496395.2014.937005
  6. Hwang, B.K., Lee C.H., Chang, I.S., Drews A. and Field, R. (2012). Membrane bioreactor: TMP rise and characterization of bio-cake structure using CLSM-image analysis, J. Membrane Sci., 419, 33-41. https://doi.org/10.1016/j.memsci.2012.06.031
  7. Kim, J.Y., Lee, J.H., Chang, I.S., Lee, J.H. and Yi, J.W. (2011). High voltage impulse electric fields: disinfection kinetics and its effect on membrane bio-fouling, Desalination, 283, 111-116. https://doi.org/10.1016/j.desal.2011.03.039
  8. Lee, J.S. and Chang, I.S. (2014). Membrane fouling control and sludge solubilization using high voltage impulse (HVI) electric fields, Process Biochem., 49, 858-862. https://doi.org/10.1016/j.procbio.2014.03.001
  9. Park, H.D., Chang, I.S. and Lee, K.J., (2015). Principles of membrane bioreactor for wastewater treatment, CRC Press, Taylor & Francis Group, New York, 242-245.
  10. Park, S.J., Lee, J.H., Chang, I.S., Kang, S.M. and Lee, J.H. (2005). "Membrane fouling control using the high voltage impulse system", Proceedings of Korea Academia-Ind. Cooperation Soc., Seoul, Korea.
  11. Somolinos, M., Manas, P., Condon, S., Pagan, R. and Garcia, D. (2008). Recovery of Saccharomyces cerevisiae sublethally injured cells after Pulsed Electric Fields, Int. J. Food Microbiol., 125(3), 352-356. https://doi.org/10.1016/j.ijfoodmicro.2008.04.023
  12. Takanori, T., Tomoki, Y., Kazukr, S., Sun, B. and Takayuki, O. (2015). Inactivation of escherichia coli phages by PEF treatment and analysis of inactivation mechanism, J. Electrostat., 73, 151-155. https://doi.org/10.1016/j.elstat.2014.11.004
  13. Um, S.E. and Chang, I.S. (2017). Effect of current density and contact time on membrane fouling in electrocoagulation-MBR and their kinetic studies on fouling reduction rate, J. Korean Soc. Water Wastewater, 31(4), 321-328. https://doi.org/10.11001/jksww.2017.31.4.321
  14. Wu, J., Le-Clech, P., Stuetz, R., Fane, A. and Chen, V. (2008). Effects of relaxation and backwashting conditions on fouling in membrane bioreactor, J. Membrane Sci., 324, 26-32. https://doi.org/10.1016/j.memsci.2008.06.057
  15. Xu, M., Wen, X., Huang, X., Yu, Z. and Zhu, M. (2013). Mechanisms of membrane fouling controlled by online ultrasound in an anaerobic membrane bioreactor for digesting of waste activated sludge, J. Membrane Sci., 445, 119-126. https://doi.org/10.1016/j.memsci.2013.06.006
  16. Zhao, W., Yang, R., Shen, X., Chen, S. and Chen, X. (2013). Lethal and sublethal injury and kinetics of Escherichia coli, Listeria monocytogenes and Staphylococcus aureus in milk by pulsed electric fields, Food Control, 32(1), 6-12. https://doi.org/10.1016/j.foodcont.2012.11.029