DOI QR코드

DOI QR Code

Mechanical Behavior of Porcine Abdominal Organ Tissue with Resuscitative Endovascular Balloon Occlusion of the Aorta

혈관내 풍선 확장에 의한 대동맥 차단소생술이 적용된 돼지 복부 장기 조직의 기계적 거동 평가

  • Wang, Il Jae (Dept. of Emergency Medicine, Pusan Nat'l Univ. Hospital) ;
  • You, Ji-Hun (Dept. of Biomedical Engineering, Graduate School, Pusan Nat'l Univ.) ;
  • Huh, Up (Biomedical Research Institute, Pusan Nat'l Univ. Hospital) ;
  • Song, Seunghwan (Biomedical Research Institute, Pusan Nat'l Univ. Hospital) ;
  • Ahn, Hyo Young (Biomedical Research Institute, Pusan Nat'l Univ. Hospital) ;
  • Song, Chan-Hee (Dept. of Biomedical Engineering, Graduate School, Pusan Nat'l Univ.) ;
  • Lee, Chi-Seung (Biomedical Research Institute, Pusan Nat'l Univ. Hospital) ;
  • Ryu, Dong-Man (Biomedical Research Institute, Pusan Nat'l Univ. Hospital)
  • 왕일재 (부산대학교병원 응급의학과) ;
  • 유지훈 (부산대학교 대학원 의공학전공) ;
  • 허업 (부산대학교병원 의생명연구원) ;
  • 송승환 (부산대학교병원 의생명연구원) ;
  • 안효영 (부산대학교병원 의생명연구원) ;
  • 송찬희 (부산대학교 대학원 의공학전공) ;
  • 이치승 (부산대학교병원 의생명연구원) ;
  • 유동만 (부산대학교병원 의생명연구원)
  • Received : 2020.02.24
  • Accepted : 2020.03.31
  • Published : 2020.04.27

Abstract

Abdominal organs are the most vulnerable body parts under vehicle trauma, and there is high mortality from acute injuries in accidents. There are various ways to reduce this high mortality; one method is Resuscitative Endovascular Balloon Occlusion of the Aorta, which has recently become very popular as a minimally invasive alternative in the emergent management of patients with non-compressible hemorrhages below the diaphragm. However, high safety factor for patients is applied in actual clinical practice because there is no exact standard for the operating time. Therefore, in this study, the effects of the mechanical behavior of organ tissues for the duodenum, kidney, and liver on the operating time of Resuscitative Endovascular Balloon Occlusion of the Aorta is investigated in order to obtain data needed to establish standards of operating time. In characteristic analysis of organ tissues, uniaxial tensile test and compression test are conducted according to the operating time.

Keywords

References

  1. M. A. Gad, A. Saber, S. Farrag, M. E. Shams and G. M. Ellabban, N. Am. J. Med. Sci., 4, 129 (2012). https://doi.org/10.4103/1947-2714.93889
  2. R. Singh, H. K. Singh, S. C. Gupta and Y. Kumar, Indian J. Community Med., 39, 30 (2014). https://doi.org/10.4103/0970-0218.126353
  3. S. Umale, C. Deck, N. Bourdet, P. Dhumane, L. Soler, J. Marescaux and R. Willinger, J. Mech. Behav. Biomed. Mater., 17, 22 (2013). https://doi.org/10.1016/j.jmbbm.2012.07.010
  4. L. A. Osborn, M. L. Brenner, S. J. Prater and L. J. Moore, Open Access Emerg. Med., 11, 29 (2019). https://doi.org/10.2147/OAEM.S166087
  5. Z. Qasim, M. Brenner, J. Menaker and T. Scalea, Resuscitation, 96, 275 (2015). https://doi.org/10.1016/j.resuscitation.2015.09.003
  6. J. J. Morrison, T. J. Percival, N. P. Markov, C. Villamaria, D. J. Scott, K. A. Saches, J. R. Spencer and T. E. Rasmussen, J. Surg. Res., 177, 341 (2012). https://doi.org/10.1016/j.jss.2012.04.035
  7. A. Okada, O. Nakamoto, M. Komori, H. Arimoto, H. Rinka and H. Nakamura, Clin. Case. Rep., 5, 1565 (2017). https://doi.org/10.1002/ccr3.1126
  8. ER-REBOATM Catheter. Prytime medical and the REBOA Company Home Page On the Web. Retrieved March 03, 2010 from https://prytimemedical.com/
  9. R. Akhtar, M. J. Sherratt, J. K. Cruickshank and B. Derby, Mater. Today, 14, 96 (2011). https://doi.org/10.1016/S1369-7021(11)70059-1
  10. K. Reik, D. Klatt, H. Nuzha, S. Mueller, U. Neumann, I. Sack and J. Braun, J. Biomech., 44, 1380 (2011). https://doi.org/10.1016/j.jbiomech.2010.12.031
  11. Z. Gao, K. Lister and J. P. Desai, Ann. Biomed. Eng., 38, 505 (2010). https://doi.org/10.1007/s10439-009-9812-0
  12. E. Roan and K. Vemaganti, J. Biomech. Eng., 129, 450 (2007). https://doi.org/10.1115/1.2720928
  13. C. Forsell, J. Swedenborg, J. Roy and T. C. Gasser, Ann. Biomed. Eng., 41, 1554 (2013). https://doi.org/10.1007/s10439-012-0711-4
  14. D. M. Pierce, F. Maier, H. Weisbecker, C. Viertler, P. Verbrugghe, N. Famaey, I. Fourneau, P. Herijgers and G. A. Holzapfel, J. Mech. Behav. Biomed. Mater., 41, 92 (2015). https://doi.org/10.1016/j.jmbbm.2014.10.003
  15. M. L. Raghavan, M. W. Webster and D. A. Vorp, Ann. Biomed. Eng., 24, 573 (1996). https://doi.org/10.1007/BF02684226
  16. D. H. Wang, M. Makaroun, M. W. Webster and D. A. Vorp, J. Biomech. Eng., 123, 536 (2001). https://doi.org/10.1115/1.1411971
  17. D. A. Manly, J. Boles and N. Mackman, Annu. Rev. Physiol., 17, 515 (2011).
  18. J. A. Ambrose and M. Weinrauch, Arch. Intern. Med., 156, 1382 (1996). https://doi.org/10.1001/archinte.1996.00440120032004
  19. B. Hmoud, A. K. Singal and P. S. Kamath, J. Clin. Exp. Hepatol., 4, 257 (2014). https://doi.org/10.1016/j.jceh.2014.03.052
  20. Y. U. Lee, A. Y. Lee, J. D. Humphrey and M. K. Rausch, Biorheology, 52, 235 (2015). https://doi.org/10.3233/BIR-15058
  21. R. A. Preston and M. Epstein, J. Hypertens., 15, 1365 (1997). https://doi.org/10.1097/00004872-199715120-00001
  22. R. E. Kleinman, I. R. Sanderson, O. Goulet, P. M. Sherman, G. Mieli-Vergani and B. L. Shneider, Walker's Pediatric Gastrointestinal Disease, 5th ed., p. 751, B. C. Decker, USA (2008).
  23. E. E. Montalvo-Jave, T. Escalante-Tattersfield, J. A. Ortega-Salgado, E. Pina and D. A. Geller, J. Surg. Res., 147, 153 (2008). https://doi.org/10.1016/j.jss.2007.06.015